• Title/Summary/Keyword: discharge-supply system

Search Result 229, Processing Time 0.031 seconds

Analysis of Acoustic Signals Produced by Corona and Series-arc Discharges (코로나와 직렬아크 방전에 의해 발생한 음향신호의 분석)

  • Jo, Hyang-Eun;Jin, Chang-Hwan;Park, Dae-Won;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • This paper dealt with the frequency component analysis of acoustic signals produced by corona and series-arc discharges as a diagnostic technique for closed-switchboards. Corona and series-arc discharge were simulated by a needle-plane electrode and an arc generator specified in UL1699, respectively. Acoustic signal was detected by a wideband acoustic sensor with a frequency bandwidth of 4 Hz~100 kHz (-3 dB). We analyzed frequency spectrums of the acoustic signals detected in various discharge conditions. The results showed that acoustic signals mainly exist in ranges from 30 kHz to 60 kHz. From the experimental results, an acoustic detection system which consists of a constant current power supply (CCP), a low noise amplifier (LNA) and a band pass filter was designed and fabricated. The CCP separates the signal component from the DC source of acoustic sensor, and the LNA has a gain of 40 dB in ranges of 280 Hz~320 kHz. The high and the low cut-off frequency are 30 kHz and 60 kHz, respectively. We could detect corona and series-arc discharges without any interference by the acoustic detection system, and the best frequency is considered in ranges of 30 kHz~60 kHz.

Identification of Normally Operating High-Voltage Cables beyond Expected Life time (예상 수명을 초과하여 정상적으로 동작하는 고압 케이블의 확인)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.207-212
    • /
    • 2015
  • Continuous, high-quality supply of electrical energy is the backbone of any modern economy. Any equipment operating at a power station must be reliable and safe. All major power supply components such as transformers, cables, generators, and switchgear need to be kept in perfect operating condition. The lifetime of power cables, used as the main means of transferring electric power, is understood to be about 30 years, from the time of manufacturing. The dielectrics between two conductors of a cable must be able to withstand electrical stresses from high-voltage input. This condition should be verified throughout the lifetime of the cable system. Several techniques, such as VLF-tan${\delta}$, partial discharge, and insulation resistance are used in order to determine the operating conditions of cables. In this paper, we present our work on insulation resistance to diagnose cables in operation at the Western Power station in Taean, Chungcheong Namdo Province, South Korea. As a result we have found cables the life time of which is 38 years.

Reservoir Routing in Estuary Lake Influenced by Tidal Effects (조석 영향을 받는 하구호에서의 저수지추적)

  • Kim, Joo-Young;Lee, Jong-Kyu;Yoon, Kwang-Seok;Kim, Han-Sup
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.722-725
    • /
    • 2007
  • Geum River Estuary Barrage is very important for the irrigation, municipal and industrial uses in the cities of Gunsan, Iksan and Jeonju. The Geum River Control Office has a flood forecasting system; however, the current system does not consider the backwater effects. As a result, it is very difficult to give correct flood information, and it is difficult to accurately assess the water resource supply and saltwater invasion into freshwater, as frequently occurs due to over-discharge during floods. In this study, we investigate the flood forecasting system for the Geum River reach influenced by the estuary barrage. The current system cannot consider the backwater effect because the estuary barrage blocks the end of the river. We calculated the discharge from the tide lock and evaluated the inside water level of the estuary barrage during floods. The results show that the calculation agrees well with the observed data at the river stage stations in the Geum River. The results also show that this program is a reasonable substitute for the current system.

  • PDF

A Study on Optimal Design of Hybrid System of New and Renewable Energy-Linked Microgrid (신재생에너지 연계형 마이크로그리드의 하이브리드시스템 최적 설계 연구)

  • Lee, Jae-Kyung;Han, Yong-Chan;Kwon, Sung-Gi;Park, Gye-Choon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.631-638
    • /
    • 2022
  • Microgrid, which enables the production and consumption of electricity to be done independently on a small scale, has been studied on one of the solutions of reinforcement for flexibility of electronic system. This study examined the application effect of new microgrid by applying hybrid battery in electric power storage device. We designed the system to highlight the advantage of each battery and complement the disadvantage by using hybrid system with Lithium-ion battery and interval Redox flow battery. It runs with lithium-ion battery during the initial startup while the Redox flow battery operates for a long time at the end of excessive period, and it enables a discharge of Lithium-ion and Redox flow battery at the same time when the load has a large output. We chose Maldives as a subject of this study for organizing and optimizing independent microgrid. Maldives is the country to accomplish 100% domestic electricity in South Asia, but the whole electric power is supplied through diesel generation imported fossil fuel. We organized and optimized microgrid for energy independence on Malahini island to solve Maldives energy cost problem and global energy environment matters. We analyzed the daily power supply and accumulated the power supply from September 18, 2018~February 11, 2019. The accumulated power supply was about 120.4 MWh and the daily power supply was about 800~1000 kWh. Based on the collected information, we divided the cases into three models which are only diesel generator, solar generator as well as diesel generator, and solar+ESS+diesel generator. We analyzed the amount of oil consumption compared to the cost of construction and power output. The result showed that solar+ESS+diesel generator was most economically feasible. As well, we obtained that our considering hybrid battery system reduced the fuel consumption for diesel power generation about 10~15%.

Environmental Change of Suspended Sediment Discharge by Human Action (인간활동으로 인한 부유토양유출의 환경변화)

  • 박종관
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.153-160
    • /
    • 1993
  • The problem of supply and transport of sediment from a mountainous catchment is very important in explaining dynamic geomorphology and the hydrological cycle. The discharge of suspended sediment is determined by a morphological system. Human interference to environment Is also an important, not negligible factor in sediment production. Moreover, growing concern in recent years for the problems of nonpoint pollution and for the transport of contaminants through terrestrial and aquatic ecosystems has highlighted the role of sediment-associated transport in fluvial systems. This study was conducted in forested and quarried catchments in order to clarify the different discharge process and the mechanism of suspended sediment dynamics for each catchment. As a forested catchment, the Yamaguchi River catchment which drains a $3.12km^2$ area was chosen. On the other hand, the Futagami River basin which is formed by three subbasins (1.07, 1.59 and $1.78km^2$), as a quarried catchment was selected. These catchments are situated to the north and east of Mt. Tsukuba, Ibaraki, Japan. The discharge pattern of suspended sediment from the Futagami River basin is more unstable and irregular than that from forested catchment, the Yamaguchi River catchment. Under the similar rainstorm conditions, suspended sediment concentration from quarried catchment during a rainstorm event increases from 43 to 27,340 mg/l. However, in the case of the forested catchment it changes only from nearly zero to 274 mg/l. Generally, the supply source of suspended sediment is classified into two areas, the in-channel and non-channel source areas. As a result of field measurements, in the case of the forested catchment the in-channel (channel bed, channel bank and channel margin) is the main source area of suspended sediment. On the other hand, remarkable sediment source area on the Quarried catchment is the non-channel that is unvegetated ground.

  • PDF

Solar ESS Peak-cut Simulation Model for Customer (수용가 대응용 태양광 ESS 피크컷(Peak-cut) 시뮬레이션 모델)

  • Park, Seong-Hyeon;Lee, Gi-Hyun;Chung, Myoung-Sug;Chae, U-ri;Lee, Joo-Yeuon
    • Journal of Digital Convergence
    • /
    • v.17 no.7
    • /
    • pp.131-138
    • /
    • 2019
  • The world's electricity production ratio is 40% for coal, 20% for natural gas, 16% for hydroelectric power, 15% for nuclear power and 6% for petroleum. Fossil fuels also cause serious problems in terms of price and supply because of the high concentration of resources on the earth. Solar energy is attracting attention as a next-generation eco-friendly energy that will replace fossil fuels with these problems. In this study, we test the charge-operation plan and the discharge operation plan for peak-cut operation by applying the maximum power demand reduction simulation. To do this, we selected the electricity usage from November to February, which has the largest amount of power usage, and applied charge / discharge logic. Simulation results show that the contract power decreases as the peak demand power after the ESS Peak-cut service is reduced to 50% of the peak-target power. As a result, the contract power reduction can reduce the basic power value of the customer and not only the economic superiority can be expected, but also contribute to the improvement of the electric quality and stabilization of the power supply system.

The impact of anthropogenic factors on changes in discharge and quality of water in the Hadano basin, Japan (인위적인 요인이 하천의 유량과 수질변화에 미친 영향 - 일본 하다노 분지를 사례 로 -)

  • ;Yang, Hea-Kun
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.3
    • /
    • pp.242-254
    • /
    • 1995
  • The Hadano Basin is located at a distance of about 70kms and 60kms from Tokyo and Yokohama and lies in the south-west part of the Kanto region in Japan. The basin area, which correspoends to the catchment of the Kaname River, is about areal size of 60.7$\textrm{km}^2$ and extends about length of 8kms in E-W direction and about width of 5kms in N-S direction (Fig.1). The Hadano basin is filled with thick pile of the alluvum from deposits composed of volcanic materials, mostly came from the Hakone Volcano and overlain by Fuji Volcanic ashes. Fluvial deposits form the good aquifer, therefore water resources of Handano City has been largely depending upon the eroundwater. Urbanization and industrialization of the basin has been rapid in the last thirty years, after activation of "Factory Attraction Policy of Hadano City" in 1956. Growth in population and number of factory due to urbanization changed the land-use pattern of the basin rapidly and increased the water demands. Therefore, Hadano City exploited a new source of water supply, and have introduced the prefectureal waterworks since 1976. On the other hand, the rapid urbanization has brought about the pollution of streams in the basin by domestic sewage and industrial waste water. Diffusion rate of sewerage systems in Hadano City is 38% in 1993. In ordcr to examine the impact of anthropogenic factors on river environments, the author took up the change of land-use and diffusion area of sewerage as parameters, and performed field surveys on water discharge and quality. The survey has been made at upstream and downstream of the main stream regularly per month, to get informati ons about the variation of discharge and water quality aiong the stream and its diurnal fluctuation. Annual variation has been analyzed based the data from Hadano City Office. The results are summarized as follows. 1. Stream discharge has been increasing by urbanization (Fig.3). Water quality (C $l^{-10}$ , N $H^{+}$$_{ 4}$-N, BOD) has been improving gradually after the application of sewerage service, yet water pollution load at the lower station has increased than that at the upper one because of the larger anthropogenic discharge volumes (Fig.4). 2. Corrclation coefficient of discharges between upper and lower was 0.81-0.92. Pollutant loads of the R. Kamame after the confluence with R. Kuzuha grew up by 2.4-3.7 times as compared with its upper reaches, and it increased to 3.7-6.9 times after the confluence with the R. Muro (Fig.5). 3. The changes of water quality along the stream can be divided into two groups (Fig.6a). First: water quality of the R. Kaname and R. Shijuhachisse is becoming worse towards the lower reaches because the water from branches are polluted. Second: water quality are improved in the lower where spring and small branch streams supply clear water, for example R. Mizunashi, R. Muro and R. Kuzuha. 4. Measured discharge at the upper station in the R. Shijuhachisse is 0.153㎥/sec, and about 55% of this is recharged until it reaches to the lower point. The R. Mizunashi has a discharge of 1.155㎥/sec at the upper point, is recharged 0.24㎥/sec until the midstream and groundwater spring 0.2㎥/sec at the lower reaches. R. Kuzuha recharged all the mountain runoff (0.2㎥/sec) at the upper reaches. The R. Muro is supplied by many springs and the estimated discharge of spring was 0.47㎥/sec (Fig.6b). 5. Diurmal variations in discharge and water quality are influenced clearly by domestic and industrial waste waters (Fig.7, 8).ed clearly by domestic and industrial waste waters (Fig.7, 8).

  • PDF

Development of Alternation Energy Using Stock Raising Excretion (축산분뇨를 이용한 대체에너지 공정 개발)

  • Cho, Hyeon-Seob;Park, Jong-Sun;Lee, Kwang-Ryon;Ryu, In-Ho;Lee, Sung-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1379-1381
    • /
    • 2002
  • Recently, environmental pollution by livestock excretion is gathering strength as livestock industry is advanced on a large scale. Bio-gas is generated more than about 70 precent if remove impurities in the course of extracting bio-gas to use livestock excretion. In this paper, we developed a device that can use it in heating after extracting bio-gas from livestock excretion collected in livestock farmhouse and can supply electricity by using generator developed in itself. Also, because this system is epoch-making no discharge system to solve smear of existing method, it is expected that we have effects to prevent environmental pollution and get alternation energy and burden on the institution to treat livestock excretion of a pig breeder is solved, if use it.

  • PDF

Numerical Analysis of Proportional Pressure Control Valve using Bondgraph (본드선도를 이용한 비례전자 감압밸브의 수치해석)

  • Yang, K.U.;Hue, J.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.62-70
    • /
    • 2008
  • The paper made a description of the method for numerical analysis and modeling of a proportional pressure control valve by bondgraph. The valve is a three port pressure regulator valve, consists of two subsystems; a proportional solenoid and a spool assembly. A purpose of this study is to analysis the dynamic characteristics of the valve using bondgraph method and to verified results that each of parameters has an effect on modeling. It considered the effect which the presence of solenoid, flow coefficient and non-linearity of resistance causes in the valve modeling. In particular, it is analyzed the effect that the solenoid interacted with modeling results and characteristics of the nonlinear resistance through orifice on the supply and discharge side of valve. Thus this paper described method to present nonlinear characteristics by bondgraph modeling method, so that we could know easily result that each parameters has an effect on the modeling.

  • PDF

Test Results of Pulsed Power Supply for Nonthermal Plasma Process (저온 플라즈마 공정용 펄스발생 전원장치의 성능시험)

  • Jang, S.D.;Byun, Y.C.;Cho, M.H.;Shin, D.N.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF