• 제목/요약/키워드: discharge uniformity

검색결과 91건 처리시간 0.029초

점적 emitter 의 성능과 수리적 특성 (Performance and Hydraulic Characteristics of Drip Emitters)

  • 이남호
    • 한국농공학회지
    • /
    • 제41권3호
    • /
    • pp.33-40
    • /
    • 1999
  • Variations in the discharge rates of drip emittes were examined to find the effects of operation pressure and the tube length and to evaluate performance of the emitters. Several point-source emitters were selected such as pressure compensated, anti-leak pressure compensated, turbulent flow regulated, flow regulated, ready-made dripper, and spaghetti. Combination of operation pressure and tube length were compared. The microirrigatioon system was operated at pressures of 0.5 , 1.0 , 1.5 and 2.0 bar. The discharge from emitters wer collected at every ten meters along the lateral tube and weighted. In order to evaluate the drip emitters performance coeffcient of discharge variation , statistical uniformity, and emission uniformity were calculated. No significant variation in discharge along drip tube resulted with all emitters. There is no trend of variatiiono of discharge rate from pressure compensated emitters with increase in operation pressures. But discharge rate from other types of emitters increased with increase in operation pressures. The nominal discharge of each emitter was secured at pressure of 1.0 bar, Evaluation using statiscal and emission uniformity coefficients indicated that most of the emitters excepts tubulent flow regulated emitter and ready-made dripper performed at excellent level.

  • PDF

친환경 정밀농업을 위한 입제 변량살포기 개발 (II) -송풍식 붐형 분두 개발과 살포균등도 - (Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (II) - Development of Pneumatic Fertilizer Blow Head and Its Application Uniformity -)

  • 김영주;김학진;서민;이중용
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.474-481
    • /
    • 2006
  • In this paper, a new type blow head was developed and pneumatic application system was evaluated. The blow head had one operating factor, inserting length of collecting plate, that was directly related to discharge rate and application pattern. To determine Proper blow head arrangement and application height, a blow head set was tested. Three-way ANOVA was conducted to investigate relationships between CV value, the discharge rate and inserting length of collecting plate. The discharge rate and inserting length of collecting plate were statistically significant at p=0.01, affecting uniformity of application pattern. The best CV value among the application tests was 23.3% when the application rate and application height was 23.5 g/sec and 80 cm respectively. The worst CV value was 63.3% in 111.4 g/sec. Therefore, it is necessary to increase number of blow head in a section of the boom in improve application uniformity.

점적관개 시설의 관개균일도 및 성능 평가 (Discharge Uniformity and Performance Assessment of Drip Irrigation System)

  • 남원호;최진용;최순군;홍은미;전상호;허승오
    • 한국농공학회논문집
    • /
    • 제54권4호
    • /
    • pp.29-38
    • /
    • 2012
  • Drip irrigation is a affordable irrigation under structured cultivation. Drip irrigation system with high uniformity can be achieved through effective design, maintenance and management of irrigation systems. Nevertheless the design guidelines have not been established for the drip irrigation system products in domestic and imported considering cultivation method and greenhouse environment in Korea. The objectives of this study were to evaluate the performance of drip irrigation system with uniformity through an experiment. The experiment was conducted to study with nine different types of emitters produced in domestic and imported. Hazen-Williams coefficients were also estimated for the drip emitter through hydraulic simulation for design use. It was found that approximately 91.5 % for 10 cm emitter spacing and 96.2 % for 30 cm emitter spacing of statistical uniformity were observed in respectively. Average emission uniformity was decreased as the reduction of emitter spacing. The results would be used in the drip irrigation system design and guideline construction.

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • 임유봉;최원호;이승훈;한우용;이종현;이상균;하정민;김종훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF

Xe형 평면광원의 방전 전극 구조 변화에 따른 전자계 특성 (The electro-magnetic properties of Xe type flat lamp by discharge electrode structure)

  • 양종경;백광현;이종찬;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.15-18
    • /
    • 2005
  • As a display becomes large recently, Acquisition of high luminance and Luminance uniformity is becoming difficult in the existing CCFL or EEFL backlight system. So, study for a performance enhancement has enforced. but lamp development of flat type is asked for high luminance and a luminance uniformity security in of LCD and area anger trend ultimately. In this paper, we changed a tip shape of an electrode for production by the most suitable LCD backlight surface light source, and confirmed discharge characteristic along discharge gas pressure and voltage, and confirmed electric field distribution and discharge energy characteristic through a Maxwell 2D simulation. Therefore the discharge firing voltage characteristic showed a low characteristic than a rectangular type and round type in case of electrode which used tip of a triangle type, and displayed a discharge electric current as a same voltage was low.

  • PDF

Xe 플라즈마 평판 램프의 전기적 특성 (Electricla Properties of Xe Plasma Flat Lamp)

  • 최용성;조재철;홍경진;이우선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.35-38
    • /
    • 2006
  • As a display becomes large recently, Acquisition of high luminance and Luminance uniformity is becoming difficult in the existing CCFL or EEFL backlight system. So, study for a performance enhancement has enforced. but lamp development of flat type is asked for high luminance and a luminance uniformity security in of LCD and area anger trend ultimately. In this paper, we changed a tip shape of an electrode for production by the most suitable LCD backlight surface light source, and confirmed discharge characteristic along discharge gas pressure and voltage, and confirmed electric field distribution and discharge energy characteristic through a Maxwell 2D simulation. Therefore the discharge firing voltage characteristic showed a low characteristic than a rectangular type and round type in case of electrode which used tip of a triangle type, and displayed a discharge electric current as a same voltage was low.

  • PDF

Xe 플라즈마 평판형 광원의 전극 구조에 따른 전기.자기적 특성 (Electrical and Electromagnetic Characteristics of Xe Plasma Flat Lamp by Electrode Structure)

  • 최용성;문종대;이경섭;이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.82-85
    • /
    • 2006
  • As a display becomes large recently, Acquisition of high luminance and Luminance uniformity is becoming difficult in the existing CCFL or EEFL backlight system. So, study for a performance enhancement has enforced. but lamp development of flat type is asked for high luminance and a luminance uniformity security in of LCD and area anger trend ultimately. In this paper, we changed a tip shape of an electrode for production by the most suitable LCD backlight surface light source, and confirmed discharge characteristic along discharge gas pressure and voltage, and confirmed electric field distribution and discharge energy characteristic through a Maxwell 2D simulation. Therefore the discharge firing voltage characteristic showed a low characteristic than a rectangular type and round type in case of electrode which used tip of a triangle type, and displayed a discharge electric current as a same voltage was low.

  • PDF

고균일 Al 박막 증착을 위한 magnetron sputtering system 개발 (Development of magnetron sputtering system for Al thin film decomposition with high uniformity)

  • 이재희;황도원
    • 한국진공학회지
    • /
    • 제17권2호
    • /
    • pp.165-169
    • /
    • 2008
  • 반도체 소자공정에서 균일한 두께의 금속박막을 증착하는 것은 매우 중요하다. 기존의 기판고정식 sputtering 장비로 증착한 indium tin oxide(ITO)박막의 두께 균일도가 $\pm4%\sim\pm5%$ 정도로 중앙부분이 더 두껍다. 방전전극 구조물을 설계하고 제작하여 sputtering되는 물질의 방향을 조절하였다. 개량된 sputtering gun을 사용하여 기판고정식 sputtering 장비에서 4" wafer 내에서 $\pm0.8\sim1.3%$ 정도로 두께 균일도를 증가시켰다. wafer to wafer에서는 $\pm$5.3%에서 $\pm$1.5%로 두께 균일도가 향상되었다. Al박막의 경우 $\pm$1.0% 이내의 두께 균일도를 얻을 수 있었다.

시설재배용 분수호스 및 점적관수 시스템의 관수균일도 분석 (Discharge Variation of Perforated Hoses and Drip Irrigation Systems for Protected Cultivation)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제16권4호
    • /
    • pp.297-302
    • /
    • 2007
  • 점적관수 자재 및 분수호스의 관수균일도 실험결과 사용압력과 배관길이에 따라 유출량의 차이가 큰 것으로 나타났다. 점적관수 중에서는 점적단추의 관수 균일도가 가장 높았고, 점적테잎, 점적호스의 순으로 나타났다. 관의 직경과 길이 및 유량에 따라 다르지만 마찰에 의한 압력손실이 상당히 크므로 점적관수의 사용압력과 배관길이 선택에 주의할 필요가 있다. 제품에 따라 약간의 차이는 있었지만 대체로 점적호스는 50m, 점적테잎은 70m 정도를 최대 배관길이로 제한하는 것이 바람직할 것으로 판단되었다. 점적단추는 실험에서 설정한 최대길이인 100m까지도 사용이 가능한 것으로 사료된다. 그러나 관수시스템의 압력을 체크하여 충분한 압력을 확보하고 있는지 검토할 필요가 있고, 부족시 별도의 가압펌프를 설치하여 적정압력 범위를 만족할 수 있도록 하며 물구멍이 막히지 않도록 필터를 설치하고 수질을 관리하는 등의 유지관리가 필요한 것으로 판단되었다. 분수호스의 경우에는 균등계수가 매우 낮아 균일한 관수를 기대할 수 없는 것으로 나타났다. 따라서 균일한 관수 제어를 필요로 하는 높은 수준의 시설재배에서는 가능한 한 점적관수를 사용하고, 비교적 낮은 수준의 배지수분 관리가 이루어지는 시설재배에서도 분수호스를 이용할 경우 배관길이를 $30{\sim}35m$이내로 제한하는 것이 바람직할 것으로 판단된다.

점적관개에 따른 토양수분 재분배 균일성 평가 (Uniformity Assessment of Soil Moisture Redistribution for Drip Irrigation)

  • 최순군;최진용;남원호;허승오;김학진;정선옥;한경화
    • 한국농공학회논문집
    • /
    • 제54권3호
    • /
    • pp.19-28
    • /
    • 2012
  • Greenhouse cultivation has been increasing for high quality and four season crop production in South Korea. For the cultivation in a greenhouse, maintaining adequate soil moisture at each crop growth stage is quite important for yield stability and quality while the behavior of moisture movement in the soil has complexity and adequate moisture conditions for crops are vary. Drip irrigation systems have been disseminated in the greenhouse cultivation due to advantages including irrigation convenience and efficiency without savvy consideration of the soil moisture redistribution. This study aims to evaluate soil moisture movement of drip irrigation according to the soil moisture uniformity assessment. Richards equation and finite difference scheme were adapted to simulate soil moisture behavior in soil. Soil container experiment was conducted and the model was validated using the data from the experiment. Two discharge rate (1 ${\ell}/hr$ and 2 ${\ell}/hr$) and three spaces between the emitters (10 cm, 20 cm, and 30 cm) were used for irrigation system evaluation. Christiansen uniformity coefficient was also calculated to assess soil moisture redistribution uniformity. The results would propose design guidelines for drip irrigation system installation in the greenhouse cultivation.