• 제목/요약/키워드: discharge measurement method

검색결과 361건 처리시간 0.029초

하천유량 측정기법에 관한 연구 (A Study on the River Discharge Measurement Techniques)

  • 김성원;지홍기
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

유량측정방법에 따른 형산강유량의 불확실도 분석 (Uncertainty Analysis of Hyung San River Discharge due to the methods of Discharge Measurement)

  • 서규우;김수현;김대곤
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1538-1542
    • /
    • 2005
  • This study is to secure more accurate data of the discharge on the measurement by gaining a reliable hydrological data through the comparison the present method of measuring them and the other way that is based ISO. This study suggests the applicable measurement method of the discharge that has reliance through general elements and the analysis of uncertainty by comparing and assaying the data of the Hyung San River that is measured by the present standard. The result of this study makes us realize that we should complement the measurement method of the discharge securing the reliable and accurate hydrological data Hydrological data is very important things to perform domestic river works or install some structure in river or coast. Securing reliable and accurate hydro-data and making a thesis should go on in other to do any construction in river or coast.

  • PDF

차량탑재형 HFPD의 개발 (The Development of HFPD System for Mibile-loading Vehicles)

  • 김덕근;임장섭;여인선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

전력용 기기의 예방진단을 위한 부분방전측정 (The measurement of partial discharge for preventive diagnosis in power machinery)

  • 김태성;구할본;임장섭;정우성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권1호
    • /
    • pp.42-48
    • /
    • 1994
  • The preventive diagnosis technique for power system is being highlighted as a research area for deterioration of insulation in machinery because of high-voltage power system. We make efforts to develop not only diagnosis of aging state but also detection of defects in the initial stage from preventive diagnosis technique. Especially, partial discharge is actively studied as a non-destructive diagnosis technique and very useful because partial discharge measurement reduces damage than conventional diagnosis technique. The loaded stress during this test is smaller than that of other diagnosis techniques. But the continuous research for various complicated analysis method is required because partial discharge has very small signals and its signals have complex forms. In this paper, the measurement of partial discharge was investigated and studied on many specimens with void. We made samples having artificial voids and measured partial discharge. In order to use as a practical diagnosis technique, we studied ways of measurement, measured illustrations and types of partial discharge which could be used in order to diagnose defects of power machinery.

  • PDF

다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석 (Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP)

  • 지주연;박승용;이광우;박경민;황순홍;김동호;이영준
    • 한국환경과학회지
    • /
    • 제22권2호
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

고전압 절연재료의 결함진단을 위한 부분방전측정 (The Measurement of Partial Discharge to Diagnose Defects in High-Voltage Insulating Materials)

  • 이정빈;정우성;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.134-138
    • /
    • 1994
  • According to request of insulating materials for high-voltage, recently we make effort not only to develop diagnostic skills of aging state but also to discover defects in insulating material in the early. Especially, partial discharge has been actively studied as a non-destructive diagnosis technique and very useful method. Because the method of partial discharge measurement has damages less than other conventional diagnosis technique. In this paper, the characteristics of partial discharge was investigated and studied on many samples with voids. In order to adapt as a practical diagnosis technique, it is studied on the characteristics of partial discharge and insulation breakdown in the high voltage. We suggest that partial discharge measurement can be used in order to diagnose defects in high-voltage insulation materials.

수심적분법에 의한 유사량 추정연구 (A Study on Estimation by Depth Integrating Method of Sediment Discharge)

  • 서승덕;김활곤;우효섭
    • 한국농공학회지
    • /
    • 제38권1호
    • /
    • pp.90-97
    • /
    • 1996
  • In Korea, total sediment discharge of a river has been estimated simply by using certain sediment transport formulas including, among others, Einstein's formula. Those formular, however, are known not to be reliable enough for the result calculated by them to be used directly to river planning and management. Therefore, the study used the Modified Einstein Procedure to the estimation of total sediment discharge, because this method is reliable estimated by measurement. Here, measurement of sediment discharge used depth integrating method. The major results obtained from the study for estimation by depth integrating method of sediment discharge in Naeseong stream are as follow; 1 The sedeiment characteristics of Naeseong stream are; The distribution of sediment grain size shows that silt and clay are 55% and sand is 45%. and the bed load sediment grain size is constituted that sand contained with the grain size from O.062mm to 2.0mm is 80% 2. The sediment rating formulas derived from the regression analysis between the sediment discharge and flow discharge are; Seogpo-Gyo : Qs=$0.017 \times 10^{-4} Q^{2.352}$, where discharge is l0cms $0.074 \times 10^{-4} Q^{2.066}$, where discharge is l0cms

  • PDF

유량측정 방법의 정확도 분석 -괴산댐 하류 달천 적용 사례를 중심으로- (Inter-comparison of Accuracy of Discharge Measurement Methods - A Case Study Performed in the Dalcheon River Downstream of the Goesan Dam-)

  • 이찬주;김동구;권성일;김원
    • 한국수자원학회논문집
    • /
    • 제43권12호
    • /
    • pp.1039-1050
    • /
    • 2010
  • 본 연구에서는 괴산댐 하류 달천에서 6가지 직접 유량 측정 방법-유속면적법, 봉부자법, ADCP이동측정법, ADCP정지 측정법, 전자파표면유속계, LSPIV-을 적용하고, 이를 댐 방류량 및 유속면적법과 비교함으로써 정확도를 상호 평가하였다. 이를 위해 2005년부터 2010년까지 실시된 총 39회의 유량측정결과가 분석되었다. 댐 방류량과의 비교 결과, 봉부자법을 제외한 나머지5가지 방법은 평균 6.2% 이내의 절대값오차를 나타냈다. 유속면적법과 다른 4가지방법을 비교할 경우, 전자파표면유속계는 7.35%, 나머지 3가지 방법은 6% 이내의 절대값오차를 나타냈다. 봉부자법은 댐 방류량 및 유속면적법과 비교하여도 오차의 범위가 크게 나타났는데, 이에 대해서는 추가적인 검증이 필요하다.

Estimation of River discharge using Very High-Resolution Satellite Data in Yangtze River

  • Zhang, Jiqun;Xu, Kaiqin;Watanabe, Masataka;Sun, Chunpeng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.728-733
    • /
    • 2002
  • The measurement of river discharge is among the most fundamental observations and is necessary for understanding many water-related issues, such as flooding hazards, sediment transportation, and nutrient movement. Traditionally river discharge is estimated by measuring the water stage and converting the measurement to discharge using a stage-discharge rating curve. The possibility of monitoring river discharge from satellites has been largely ignored, because it is difficult to measure water surface information from space with sufficient precision. In this paper, an efficient approach to discharge estimation using mainly satellite data is developed and described. The proposed method, which focuses on the measurement of water-surface width coupled with river width-stage and stage-discharge relationships, is applied to the Yangtze River with good results.

  • PDF

엔트로피 개념에 의한 유량측정 기법 (Measurement of Discharge Using the Entropy Concept)

  • 추태호;이승관
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2006년도 춘계 종합학술대회 논문집
    • /
    • pp.342-346
    • /
    • 2006
  • 그 동안 기술적 또는 이론적 배경의 취약으로 인하여 측정이 매우 어렵거나 불가능했던 유량을 산정하는데 유효하게 적용할 수 있으며, 형상에 관계없이 측정비용 및 시간을 많이 줄일 수 있다. 더욱이 전자파 표면 유속계와 함께, 실시간 유입수문곡선을 만들 수 있는 실시간 유량 측정 시스템을 개발하는데 사용될 수 있다.

  • PDF