• 제목/요약/키워드: discharge channel

검색결과 483건 처리시간 0.03초

수문운영에 따른 낙단보 상류하도 흐름특성 해석 (Analysis of Flow Characteristics in Upstream Channel depending on Water Gate Operation of Nakdan Multi Functional Weir)

  • 문상철;박기범;안승섭
    • 한국환경과학회지
    • /
    • 제25권4호
    • /
    • pp.491-504
    • /
    • 2016
  • This study, examines the flow characteristics of upstream channel depending on water gate operation of Nakdan Multi-fuctional weir. The specific purpose of this study are to simulate the variation of flow velocity depending on the operation of the weir using 1-dimensional hydraulic model, HEC-RAS, and compare it with observed velocity. For discharge conditions from $50m^3/s$ to $3,500m^3/s$, it is observed that the velocity of upstream channel is almost constant, whereas for probability flood discharge, the velocity and froude number are increased as the discharge values are increased. The velocity values for downstream boundary condition EL, 40.0 m are more decreased than those for EL. 40.5m. From comparison on the variation of water stage depending on water gate operation, it is observed that the stage values are almost constant for discharges below $300m^3/s$, whereas 5 cm to 20 cm for discharges over $700m^3/s$. Flow velocity at streamflow gauging station. Nakdong, is decreased by more than 875% after installing the weir. The results obtained from this study indicate that the velocity of upstream channel is decreased and the discharge and velocity of downstream channel are significantly varied after installing the weir.

개수로에서의 대표 매개변수 방법에 의한 유량산정에 관한 연구 (A Study on Discharge Estimation by Representative Parameter Method in Open Channels)

  • 추태호;채수권
    • 한국습지학회지
    • /
    • 제14권4호
    • /
    • pp.637-644
    • /
    • 2012
  • 습지 생태계 및 하천에서 가장 중요한 요소인 유량의 산정은 항상 중요한 관심사였다. 이러한 유량의 산정은 그동안 수위유량 관계곡선에 의존하여 왔으나 수위와 유량만의 관계를 이용하는 수위-유량곡선의 한계점은 널리 알려져 있다. 따라서 본 논문에서는 개수로에서 널리 사용되는 Manning식과 Chezy식을 사용하여 구간 내 대표 매개변수 산정법을 통하여 유량 산정 방안을 제안하였다. 각각의 결과는 RMSE와 Discrepancy Ratio를 사용하여 나타내었고 실험실 수로와 자연하천에서 측정된 데이터에 대한 결과의 차이는 존재하였으나 산정된 유량과 측정된 유량 사이가 비교적 잘 일치함을 알 수 있었다. 지속적인 연구를 통하e여 여러 하천에 대한 검증이 이루어지고 개선이 이루어진다면 쉽고 빠르게 하천의 유량을 산정할 수 있으므로 수자원 분야에 활용될 수 있을 것으로 기대한다.

본류수로의 제방사면경사에 따른 광정횡월류위어의 유량계수 산정 (Estimation of discharge coefficients of the broad-crested side weir with various levee's side slope of main channel)

  • 강호선;조홍제
    • 한국수자원학회논문집
    • /
    • 제49권11호
    • /
    • pp.941-949
    • /
    • 2016
  • 국본 연구에서는 본류수로의 제방사면경사($ES_{ch}$)에 따른 광정횡월류위어에서의 흐름변화를 수리모형실험을 통해 분석하고, 그에 따른 유량계 수산정식을 제시하였다. 제방사면경사는 실제 하천에서의 적용성을 고려하여 1:0.5, 1:1, 1:2를 선정하였다. 제방사면경사가 포함된 광정횡월류위어의 유량계수산정식은 기존의 유량계수산정식 보다 합리적이고 적용성이 높은 것으로 확인되었다. 다중회귀분석결과 변수 중 본류수로의 제방사면경사($ES_{ch}$)>횡월류위어높이-상류수심비($h/y_u$)>횡월류위어길이-상류수심비($L/y_u$)>상류 푸르드수($Fr_u$)의 순서로 중요도가 높은 것으로 나타났다. 특히 기존의 연구와 개수로 흐름에서 가장 중요한 인자인 Froude수가 포함되지 않은 유량계수산정식을 제안하였으며, 그 적용성도 높은 것으로 나타났다.

수치 해석을 통한 절연 게이트 양극성 트랜지스터 모듈의 히트 싱크 유로 형상에 따른 방열 성능 분석 (Numerical analysis of heat dissipation performance of heat sink for IGBT module depending on serpentine channel shape)

  • 손종현;박성근;김영범
    • 한국산학기술학회논문지
    • /
    • 제22권3호
    • /
    • pp.415-421
    • /
    • 2021
  • 본 연구는 절연 게이트 양극성 트랜지스터 모듈의 히트 싱크의 유로의 형상으로써 직선 유로, 한 번 꺾인 형태의 유로, 두 번 꺾인 형태의 유로를 적용하여, 유로의 형상에 따른 방열 성능을 분석하였다. 각 유로 형상에서 운전 조건에 대한 영향 또한 분석하기 위하여 냉각수의 유량과 공급 온도를 추가적으로 제어하며 분석을 진행하였다. 본 연구는 유동 해석을 통하여 이루어 졌으며, 상용 소프트웨어인 ANSYS Fluent를 사용하였다. 직선 유로보다 꺾인 형태를 갖는 유로의 방열량이 같은 운전 조건에서 최대 8.0 % 수준 개선되었으며, 개선 정도는 냉각수의 공급 온도와는 무관하였고, 냉각수의 유량이 많아질수록 개선 정도가 2.0 %에서 8.0 %까지 증가하였다. 그러나 두 번 꺾인 유로는 한 번 꺾인 유로와 비슷한 수준의 방열 성능을 보였고, 기생 손실에 영향을 주는 압력 강하량은 2.48~2.55배 수준으로 증가하는 결과를 보여, 방열 효율이 낮아지는 것을 확인 하였다. 이를 단위 압력 강하량 당 방열량으로 계산하여 비교하였으며, 직선 유로를 갖는 히트 싱크에서 그 값이 가장 높은 것을 확인하였다.

TELEMAC-2D모형을 이용한 개수로 분류흐름에 대한 수치모의 연구 (Numerical study of dividing open-channel flows at bifurcation channel using TELEMAC-2D)

  • 정대진;장창래;정관수
    • 한국수자원학회논문집
    • /
    • 제49권7호
    • /
    • pp.635-644
    • /
    • 2016
  • 본 연구에서는 2차원 수치모형을 이용하여 개수로 분류부에서 분류수로 폭과 유량비 변화에 따른 흐름특성을 파악하였다. 2차류 영향을 고려한 분류부 수치모의시 흐름분포를 실험결과에 더 정확하고 안정하게 모의가능하다. 분류수로내 통수능을 감소시키는 흐름분리구역과 2차류의 상호 작용에 의한 흐름정체 효과는 분류유량비를 감소시킨다. 분류부 상류 유입유량과 유속이 감소할수록 수로폭 변화에 따른 분류유량비 변화가 더 크다. 동일 하류단 경계조건에서 분류수로 폭을 감소시킬 때, 본류 하류부 프루우드 수-분류유량비 관계식의 변화율은 -2.4843~-2.6675로 유사하게 나타난다. 동일 분류유량비 조건에서 분류수로 폭이 감소할수록 수축계수는 증가하고, 흐름분리구역의 폭은 감소한다. 분류수로 폭을 증가시킬 경우 분류부 상류 유입유량이 적을수록, 그리고 분류부 상류 유입량을 증가시킬 경우 분류수로 폭이 좁을수록 흐름분리구역 폭 감소율이 더 크다. 동일 상류 유입유량 조건에서 분류수로 폭이 감소할수록 분류유량비, 흐름분리구역의 길이와 폭은 감소한다.

NSCR_PPS 소자에서 채널차단 이온주입 변화에 따른 최적의 정전기보호소자 설계 (Optimal Design of ESD Protection Device with different Channel Blocking Ion Implantation in the NSCR_PPS Device)

  • 서용진;양준원
    • 한국위성정보통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.21-26
    • /
    • 2016
  • PPS 소자가 삽입된 N형 실리콘 제어 정류기(NSCR_PPS) 소자에서 채널차단영역의 이온주입 변화가 정전기 보호 성능에 미치는 영향을 연구하였다. 종래의 NSCR 표준소자는 on 저항, 스냅백 홀딩 전압 및 열적 브레이크다운 전압이 너무 낮아 마이크로칩의 정전기보호소자로 적용이 어려웠다. 그러나 본 연구에서 제안하는 채널 차단 영역의 이온주입 조건을 변화시켜 각각 변형설계된 소자에서는 채널 차단 이온주입이 정전기 보호성능의 향상에 영향을 주는 중요한 파라미터였으며, CPS_PDr+HNF 구조의 변형소자는 정전기보호소자의 설계창을 만족시키는 향상된 정전기보호성능을 나타내어 고전압 동작용 마이크로 칩의 정전기보호 소자로 적용 가능함을 확인하였다.

중소하천(요천)에서 지배유량 연구 (A study on the dominant discharge in small and medium-sized stream (Yo-Stream))

  • 임창수;이준호
    • 농업과학연구
    • /
    • 제38권2호
    • /
    • pp.309-314
    • /
    • 2011
  • The purpose of this study is to select the dominant discharge which mostly affects the formation of the channel shape in Yo-Stream. So far, three different discharge conditions such as bankfull discharge, discharge of a specific recurrence interval, and effective discharge have been considered as an indicator of dominant discharge. Therefore, three different discharge conditions were studied and based on the study results, dominant discharge was selected for Yo-Stream. When comparing bankfull discharge and effective discharge at Beonam stream gaging station, it has turned out that effective discharge was 10 $m^3$/sec, which is 6 times greater than bankfull discharge of 58.83 $m^3$/sec. Furthermore, when comparing bankfull discharge and discharge of a specific recurrence interval, bankfull discharge was quite similar to discharge with recurrence interval of 1.52 years. Previous study results also indicate that dominant discharge occurs with recurrence interval of similar duration. Therefore, discharge of 58.83 $m^3$/sec was considered as a dominant discharge, which corresponds to discharge with recurrence interval of 1.52 years.

DBD (Dielectric Barrier Discharge)를 이용한 유량 센서 개발에 관한 연구 (Development of a Flow Sensor Using DBD (Dielectric Barrier Discharge))

  • 김태훈;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2076-2081
    • /
    • 2008
  • In this study, a new concept of a flow sensor is developed using dielectric barrier discharge (DBD). Current of DBD generated between two electrodes is changed with varying flow rates. Therefore, it is possible to measure the flow rate by correlating generated DBD current with flow rates. The effects of flow rate, frequency, channel height, diameter of electrodes and distance between electrodes on the performance of the flow sensor using DBD are experimentally investigated.

  • PDF

원자력발전소 직류전원계통용 축전지 성능시험 분석 (Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant)

  • 김대식;차한주
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

댐붕괴시 홍수가 하천하류에 미치는 영향 (The Effect of Flood Discharge due to Dam Breach on Downstream Channel)

  • 안상진;이준근;연인성;유형규
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1666-1670
    • /
    • 2006
  • The purpose of this study is to analyze how a downstream channel is affected in case of hypothetical dam failure. The object of it is Hwacheon dam basin within the basin of North Han river. This study has analyzed the influence on Pyeonghwa(Peace) dam and Hwacheon dam supposing that the Imnam dam in North Korea on the upper stream of North Han river is failed hypothetically at the MFWL(maximum flood water level) by a deluge of rain. The model applied at the main study is NWS(National Weather Service) FLDWAV(Flood Wave Routing Model). Dam breach characteristics data are analyzed by making nine hypothetical scenarios on the basis of other studies on the shape and size of dam breach, time of failure and so on. Expected peak discharge through the breach is verified to have the propriety in comparison with empirical function which is developed on the basis of the case of dam breach in the foreign countries and it is observed that peak discharge is more increasing, as the time of breach gets shorter and the breach width gets bigger. As a result of main study, even though the Imnam dam is hypothetically failed down, there has no influence on the Hwacheon dam of the downstream as the extended Pyeonghwa dam on the downstream controls the volume of discharge properly.

  • PDF