• Title/Summary/Keyword: discharge cells

Search Result 388, Processing Time 0.025 seconds

A Study on the Discharge Characteristics of an Ac PDP with the Variation of Scan Electrode Driver (PDP 스캔 전극 구동방식에 따른 방전 특성의 변화에 관한 연구)

  • Kim, Joong-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.13-18
    • /
    • 2005
  • The variation of discharge characteristics of an ac PDP was observed with the charge of scan electrode driving circuit. Conventional scan electrode driving circuit provides two switches per one scan line, and the suggested one can be constituted by one switch per one scan line with the consideration of capacitive load characteristic of an ac PDP. To verify the workability of the suggested scheme, the performances of the ac PDP was investigated. The dynamic voltage margin was slightly decreased with the adoption of the suggested scheme, which is estimated to result from the misfiring of unselected discharge cells due to the deformation of voltage level of the neighboring scan electrode. In the observation of the delay characteristics of addressing discharge, the performances of the conventional circuit and the suggested one are assumed to be equivalent.

The Coating Effects of Al2O3 on a Li[Li0.2Mn0.54Co0.13Ni0.13]O2 Surface Modified with (NH4)2SO4

  • Oh, Ji-Woo;Oh, Rye-Gyeong;Hong, Jung-Eui;Yang, Won-Geun;Ryu, Kwang-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1516-1522
    • /
    • 2014
  • A series of 20 wt % $(NH_4)_2SO_4$ and 3 wt % $Al_2O_3$ surface treatments were applied to $Li[Li_{0.2}Mn_{0.54}Co_{0.13}Ni_{0.13}]O_2$ substrates. The $Li[Li_{0.2}Mn_{0.54}Co_{0.13}Ni_{0.13}]O_2$ substrates were synthesized using a co-precipitation method. Sample (a) was left pristine and variations of the 20 wt % $(NH_4)_2SO_4$ and 3 wt % $Al_2O_3$ were applied to samples (b), (c) and (d). XRD was used to verify the space group of the samples as R$\bar{3}$m. Additional morphology and particle size data were obtained using SEM imagery. The $Al_2O_3$ coating layers of sample (b) and (d) were confirmed by TEM images and EDS mapping of the SEM images. 2032-type coin cells were fabricated in a glove box in order to investigate their electrochemical properties. The cells were charged and discharged at room temperature ($25^{\circ}C$) between 2.0V and 4.8V during the first cycle. The cells were then charged and discharged between 2.0V and 4.6V in subsequent cycles. Sample (d) exhibited lower irreversible capacity loss (ICL) in the first charge-discharge cycle as compared to sample (c). Sample (d) also had a higher discharge capacity of ~250 mAh/g during the first and second charge-discharge cycles when compared with sample (c). The rate capability of the $Al_2O_3$-coated sample (b) and (d) was lower when compared with sample (a) and (c). Sample (d), coated with $Al_2O_3$ after the surface treatment with $(NH_4)_2SO_4$, showed an improvement in cycle performance as well as an enhancement of discharge capacity. The thermal stability of sample (d) was higher than that of the sample (c) as the result of DSC.

Characteristics of MCMB Anode with VGCF As a Conducting Agent for LPB (LPB용 MCMB 부극 도전재로 VGCF를 첨가한 부극의 특성 연구)

  • Jin Bong-Soo;Doh Chil-Hoon;Moon Seong-In;Yun Mun-Soo;Jeong Jae-Kook;Nam Hyo-Duk;Park Hei-Gu
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.143-147
    • /
    • 2004
  • An investigation upon the characterization of MCMB anodes with different vapor grown carbon fiber (VGCF) content for application in lithium polymer battery(LPB) was carried out. When VGCF material was used as conducting agent with MCMB active material, the impedance and the initial coulombic efficiency of test cells were found to decrease with the increasing amount of VGCF. On the other hand, as a function of added VGCF the discharge capacity and the utilization linearly with increased. Impedance of test cell with MCMB anode containing $6wt\%$ VGCF exhibited the lowest value whereas the impedance of $8wt\%$ VUF contained anode was similar to that of MCMB anode without VGCF. Interestingly, $6wt\%$ VUF contained anode showed the best battery characteristics. Internal resistance and rate capacity of the cell were. respectively, $0.918{\Omega}\;at\;25C\;and\;93\%$ at 2C. Generally, rate capability and the cycleability of MCMB based test cells with $4\~6wt\%$ VGCF content exhibited better results than the other cells. In the case of $6wt\%$ VGCF containing anode, the discharge capacity of the cell faded slowly with an ultimate charge-discharge cycling capacity of 178mAh/g at the 100th cycle. Thereafter, the discharge capacity faded negligibly and the utilization of the cell at the 100th cycle was more than $90\%$. The effect of addition of VGCF is discussed in detail.

Discharge Patterns and Peripheral Nerve Inputs to Cardiovascular Neurons in the Medulla of Cats: Comparison between the lateral and medial medulla

  • Kim, Sang-Jeong;Lim, Won-Il;Park, Myoung-Kyu;Lee, Jin;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • v.28 no.2
    • /
    • pp.133-141
    • /
    • 1994
  • The discharge patterns and peripheral nerve inputs to cardiovascular neurons were investigated in rostral ventrolateral medulla (RVLM) and raphe nucleus of cats. The data from the two were compared to determine their roles in cardiovascular regulation and the endogenous analgesic system. Animals were anesthetized with ${\alpha}-chloralose$ and single cell activities were recorded by carbon-filament microelectrode and their relationships with cardiovascular activity were analyzed. In RVLM area, a total of thirty-three cells were identified as cardiovascular neurons. During one cardiac cycle, the mean discharge rate of the neurons was $1.96{\pm}0.29$ and the peak activity was observed 45 ms after the systolic peak of arterial blood pressure. Thirteen cells could be activated antidromically by stimulation of the the $T_2$ intermediolateral nucleus. Forty-three raphe neurons were identified as cardiovascular neurons whose mean discharge rate during one cardiac cycle was $1.02{\pm}0.12$. None of these cells could be activated antidromically. Study of the interval time histogram of RVLM neurons revealed that the time to the first peak was $128{\pm}20.0\;ms$, being shorter than the period of a cardiac cycle. The same parameter found from the raphe neurons was $481{\pm}67.2\;ms$, which was much longer than the cardiac cycle length. Of seventeen RVLM neurons examined ten received only the peripheral $A{\delta}-afferent$ inputs, whereas six RVLM neurons received both $A{\delta}-$ and C-inputs; the remaining one cell received an inhibitory peripheral C-input. In contrast, nine of eleven raphe neurons were found to receive $A{\delta}-inputs$ only. We conclude that the main output of cardiovascular regulatory influences are mediated through the RVLM neurons. The cardiovascular neurons in the raphe nucleus appear to serve as interneurons transferring cardiovascular afferent information to the raphespinal neurons mediating the endogenous analgesic mechanisms.

  • PDF

Cytologic Features of Adenoma Malignum of the Uterine Cervix - A Case Report - (자궁경부 Adenoma Malignum의 세포학적 소견 - 1예 보고 -)

  • Choi, Hyun-Joo;Kim, Young-Shin;Lee, Kyo-Young;Kang, Chang-Suk;Shim, Sang-In
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.2
    • /
    • pp.201-205
    • /
    • 1998
  • Adenoma malignum is an extremely well-differentiated variant of cervical adenocarcinoma in which the cells composing the tumor lack the typical cytological features of malignancy. The prognosis of this rare tumor is poor in spite of high degree of differentiation. The cytologic characteristics are extremely bland so frequently make a confusion of adenoma mailgnum with endocervical glandular hyperplasia. We report a case of adenoma malignum in a 35-year-old woman who complained of mucoid vaginal discharge and vaginal bleeding. The cervicovaginal smear showed endocervical cells exhibiting a spectrum of atypical chances. The cells were arranged in multilayered strips and monolayered sheets. Individual cells ranged from cuboidal to columnar; typically the columnar cells had abundant lacy or vacuolated cytoplasm. The smear showed the majority of only atypical cells and small numbers of frankly malignant cells.

  • PDF

Examination of $\alpha$-terpinene on Primary Eye Irritancy and Skin Sensitization

  • Park, Byeoung-Soo;Choi, Won-Sik;Lee, Sung-Eun
    • Molecular & Cellular Toxicology
    • /
    • v.3 no.1
    • /
    • pp.68-75
    • /
    • 2007
  • [ $\alpha$ ]-Terpinene has been known as a repellent against the mosquito Culex pipiens pallens Coquillett based on a human forearm bioassay. $\alpha$-Terpinene showed significantly greater repellency than a commercial formulation, N, N-diethyl-m-methylbenzamide (deet). In this study, skin and eye sensitivity of $\alpha$-terpinene (2%) was examined with bioassays using white New Zealand rabbits. There were somewhat gross and histological changes observed in these treatments. Eye irritancy assays examined gross changes to cornea, iris and conjuctiva, and histological changes to smear of ocular discharge and eye tissue. Treated rabbits were divided into two cohorts, a saline washed cohort (W) or a non-washed cohort (NW). Opacity of cornea and redness, chemosis and discharge of conjuctiva were observed in both cohorts, but disappeared within 4 and 10 days in W and NW, respectively. Main components of ocular discharges were fibrin, epithelial or epitheloid cells, lymphoid cells, erythrocytes and granulocytes. These abnormal cellular components disappeared within 4 days and 10 days in W and NW, respectively. No permanent histological differences were observed between the two cohorts. However, severe irritation was determined as 57.2 of I.I.O.I value on the first day after treatment. These findings indicate a spray-type solution containing 2% $\alpha$-terpinene may serve as an alternative mosquito repellent and further studies need to reduce the eye irritation with formulation changes.

Cell-compatibility of physicochemically and biologically modified polymer surfaces (물리화학적 및 생물학적으로 표면개질된 고분자의 세포 적합성 연구)

  • Lee, J.H.;Park, K.H.;Khang, G.S.;Lee, H.B.;Andrade, J.D.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.1-3
    • /
    • 1989
  • We have treated polymer surfaces such as polyethylene, polystyrene and polyester by various physicochemical and biological surface modification methods to be suitable for cell adhesion. The physicochemical methods we used were $O_2$ plasma discharge, corona discharge, sulfuric acid and chloric acid treatments. For the biological treatments, blood proteins such as plasma protein, serum protein and fibronectin were adsorbed onto the polymer surfaces. Chinese Hamster Ovary (CHO) cells were cultured on the surface-modified polymers and the cell-compatibility of those surfaces were compared. The chloric acid and fibronectin treatments were found to be the best methods of rendering the polymer surfaces adhesive for CHO cells.

  • PDF

Improved Cycle Performance of Sulfur-Doped LiFePO4 Material at High Temperatures

  • Lee, Seung-Byung;Cho, Seung-Hyun;Aravindan, Vanchiappan;Kim, Hyun-Soo;Lee, Yun-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2223-2226
    • /
    • 2009
  • Pristine and sulfur-doped (LiFe$PO_{3.98}S_{0.03}$) lithium iron phosphates were synthesized by a sol-gel method. The XRD pattern of the prepared materials suggested an orthorhombic structure with a Pnma space group and an absence of impurities. The Li/LiFe$PO_4$ or LiFe$PO_{3.98}S_{0.03}$ cells were employed for cycling studies at various temperatures (25, 50 and $60\;{^{\circ}C}$). In all cases, the Li/LiFe$PO_{3.98}S_{0.03}$ cell showed an improved performance with a stable discharge behavior of ~155 mA$hg^{-1}$. Nevertheless, pristine LiFeP$O_4$ cells presented poor discharge behavior at elevated temperatures, especially $60\;{^{\circ}C}$.

A Study on the Electrochemical Properties of Carbon Nanotube Anodes Using a Gradual Increasing State of Charge Method

  • Doh, Chil-Hoon;Park, Cheol-Wan;Jin, Bong-Soo;Moon, Seong-In;Yun, Mun-Soo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.1
    • /
    • pp.21-25
    • /
    • 2004
  • From the gradual increasing state of charge (GISOC) observations, electrochemical behavior of multi-walled carbon nanotube│(lM LiP $F_{6}$ , EC,DEC,DME 3:5:5 volume ratio)│lithium cells was evaluated using the galvanostatic charge-discharge process. A MWCNT delivers a specific charge capacity of 1,300 mAh/g in a Li cell when cycled up to an end voltage of 0 V (vs. Li/L $i^{+}$ )at a constant current rate every 10 hours. However, in the present study, the specific discharge capacity obtained is 338 mAh/g, thus amounting to a coulombic efficiency of only 26%. Further, when the MWCNT│Li cells were tested using the GISOC method, two distinguishable linear-fit ranges were observed due to the intercalation/deintercalation of lithium, which were found to have II $E_1$, IIC $s_1$ and II $E_2$of 27.3%, 372 mAh/g, and 25.5%, respectively. Q $c_1$, could be calculated from the data of IIE and IICs of each range by the modified equation "II $C_{sum}$= $\Sigma$( $Q_{C}$- $Q_{D}$)=(II $E_{1}$$^{-1}$ ) $Q_{Dl}$ +(II $E_2$$^{-1}$ -1) ( $Q_{D2}$- $Q_{Dl}$ ) + IIC $s_1$= $Q_{Cl}$ - $Q_{Dl}$ ". Results of the GISOC method could be converted to the results of galvanostatic charge-discharge process, irrespective of the state of charge of the cell or battery.ery.y.y.

Transport of space charge between sub-pixels in AC-plasma cell discharge

  • Lee, S.B.;Park, E.Y.;Han, Y.G.;Moon, M.W.;Oh, P.Y.;Song, K.B.;Lee, H.J.;Son, C.G.;Jeong, S.H.;Yoo, N.L.;Hong, Y.J.;Jeong, S.J.;Kim, J.H.;Park, S.O.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.929-931
    • /
    • 2006
  • In this experiment, we have investigated that the transported space charge between sub-pixels in AC-plasma cell discharge. The test pulse 30 V, $5{\mu}s$ was applied to the address electrodes of neighbor cells of discharge occurred cells. And we have measured the transported space charge between sub-pixels in accordance with the various last sustain pulse widths t(time gap between the rising edges of sustain and test pulses) of 0.2 to $3{\mu}s$. It was observed that the peak value of transported space charge has been shown to be 21.5pC at $1.0{\mu}s$. And the IR peak value have been occured after $0.51{\mu}s$ with respect to sustain voltage.

  • PDF