• 제목/요약/키워드: discharge area

검색결과 1,544건 처리시간 0.027초

유량변동에 따른 소양강유역 수질의 통계학적 해석 (A Stochastic Analysis of the Water Quality on the Basin of Soyang River with Discharge Variation)

  • 최한규;백경원;최용묵;최진우
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.233-240
    • /
    • 2001
  • This research was conducted with the aim of efficiently managing large scale of rivers such like Songyang-river through predicting water quality change with analyzing the characteristics of the flowing in nutrients and pollutants. The main result will be used as basic data for effectively operating reservoirs through controling water quality and quantity. The relationship between quantity of flow and water quality was analyzed and pollution loading into the basin was estimated. Three areas of Soyang-river upstream and one area of Suip-cheon in Yanggu-gun were selected as research sites. Flow and water quality were measured simultaneously. The relation between quantity of discharge and pollution concentration and between quantity of discharge and pollution loading were analyzed by statistical method, respectively. We provided a rating curve through measuring quantity of discharge(collecting quantity of discharge) and pollutograph and pollution loading curve through water quality data. Also, we analyzed the correlation between quantity of discharge per unit area and pollution loading per unit area in each basin. As resurt of this research, Buk-cheon spot revealed an excellent first grade water quality for the items including $BOD_5$, DO, and SS. The correlation coefficient between Buk-cheon spot's quantity of discharge and pollution loading was 0.896~0.996, showing the validity of analysis applying correlation curve formula of quantity of discharge and pollution loading in the same spot. Also, pollution loading per unit area of the items including $BOD_5$, COD, DO, SS, T-N, T-P increased as the area of basins get increased following the sequence of Buk-cheon, Suip-cheon, Naelin-cheon spots.

  • PDF

HyGIS-SWAT을 이용한 토지피복도에 따른 유출부하 평가 (Estimation of Flow Loads for Landcover Using HyGIS-SWAT)

  • 김주훈;김경탁
    • 한국지리정보학회지
    • /
    • 제14권2호
    • /
    • pp.28-39
    • /
    • 2011
  • 본 연구는 HyGIS-SWAT 모형을 이용하여 환경부의 대분류/중분류에 따른 유출부하 특성을 평가하고, 토지피복변화에 따른 유출부하 특성을 평가하는 것을 목적으로 하고 있다. 대분류와 중분류 토지피복변화는 두 유역 모두 시가지 지역과 농업지역이 팽창하고 산림지역이 감소하는 것으로 분석되어 현재 지속적으로 도시화가 확대되는 추세를 반영하고 있는 것으로 판단된다. 분류항목특성에 따른 분석결과는 무심천유역의 경우 첨두유출은 상승하였고, 연총유출량은 감소하는 것으로 분석되었다. 구축시기에 따른 특성 분석결과는 갑천유역의 경우 첨두유출은 감소하고, 총유출은 증가하는 것으로 나타났다. 토지피복변화 시나리오는 도시화 확대와 농업지역 확대의 3가지 시나리오를 적용하여 분석하였다. 분석결과 도시화 및 농업지역 확대 시나리오 모두 유출 및 유사농도가 증가하는 것으로 분석되었다.

3차원 방전가공에서 전류밀도를 고려한 방전가공조건 결정 (Determination of Machining Parameters Considering Current Density in Three Dimensional Electrical Discharge Machining)

  • 이건범;김정두;최병훈;송희덕
    • 한국생산제조학회지
    • /
    • 제8권3호
    • /
    • pp.100-106
    • /
    • 1999
  • Owing to the complexity of electrical discharge machining (EDM) phenomenon, it is very difficult to determine optimal machining parameters fer improving machining performance. This paper proposes a methodology for determining optimal electrical discharge machining parameters, which is maintaining suitable current density for increasing productivity or improving surface roughness. Machining area is closely related on optimal machining parameters in electrical discharge machining process, so calculation of machining area is needed in order to determine optimal machining parameters. In this study machining area, which is corresponding to the machining position, is calculated from intersection curves between the tool surface and a horizontal plane.

  • PDF

추간판 탈출증의 수핵 탈출부위와 요근의 좌우 단면적 넓이와의 상관관계 (A Study on Correlation between the Axial Section Area in Psoas Major Muscle and Nucleus Discharge Part of HIVD of L-spine)

  • 김형길;이동은;조웅희;김두희;박원형;차윤엽;최가영
    • 한방재활의학과학회지
    • /
    • 제21권4호
    • /
    • pp.111-118
    • /
    • 2011
  • Objectives: This study was designed to correlation between the axial section area in psoas major muscles and uncleus discharge pat of HIVD(herniated intervertebral disc) of lumbar(L)-spine. Methods: We measured the axial section area in psoas muscles. Then through the medical charts, we investigated nucleus discharge pat of HIVD of L-spine. We analyzed the relationship between them. Results: There was no significant correlation nucleus discharge part and psoas major muscle's axial section area. There was significant correlation aging and psoas major muscle's axial section area with control the sex. Conclusions: According to above results, there was no significant the area of axial section in psoas major muscles and nucleus discharge part of HIVD of L-spine.

수질오염총량관리 단위유역별 오염물질 배출부하량 특성분석 - 금강수계를 대상으로 (Characterization on the Pollution Discharge Load at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin)

  • 박준대;최옥연;오승영
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.786-795
    • /
    • 2012
  • Water quality management should be focused on the pollution concentrated area so that the improvement of water quality can be achieved effectively for the management of Total Maximum Daily Loads (TMDLs). It is necessary to consider discharge characteristics in the TMDL plan. This study analysed discharge characteristics such as pollution generation and discharge load density, and reduction potential by each unit watershed, and categorized the unit watershed into four groups according to its discharge load characteristics. This analysis can be used as helpful information for the prioritization of pollution reduction area and selection of pollution reduction measures in the development of TMDL plans.

한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I) (Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea)

  • 이순혁
    • 한국농공학회지
    • /
    • 제19권1호
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

부산지역의 해저용출수 전기비저항탐사 (Resistivity Exploration of Submarine Groundwater Discharge in Busan Area)

  • 박준규;김성욱;이진혁;김인수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.711-716
    • /
    • 2010
  • This study selected the promising area of submarine groundwater discharge(SGD) that flows into the sea following unconfined physical aquifer through the electrical resistivity survey of the land and sea. The submarine groundwater discharge(SGD) mostly flows into the sea following fracture zones, and the detection of the fault zone becomes the important guideline of groundwater discharge. Electrical sounding of the land assessed the groundwater flow and integration possibility according to the location of a fault that is a water path between underground reservoir and surface water as well as a rock fracture. In addition, the study conducted sea electrical resistivity to expand the area with high potential and selected the expected water potential groundwater area. The areas of the study were Busan and coastal areas, and for the terrain analysis, the candidates of the ground exploration were selected after analyzing lineaments that is expanded to coast direction.

  • PDF

영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구 (Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin)

  • 진영훈;박성천
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.

원자력 발전소의 온배수 배출량 변화에 따른 대형저서동물 군집의 공간 변화 (Spatial Variation in Macrobenthic Communities Affected by the Thermal Discharge Volumes of a Nuclear Power Plant on the East Coast of Korea)

  • 유옥환;이형곤;이재학;김경태;명철수;문형태;변주영
    • Ocean and Polar Research
    • /
    • 제35권4호
    • /
    • pp.299-312
    • /
    • 2013
  • This study analyzed the species composition and density of a macrobenthic community according to variations in the thermal discharge volumes of a nuclear power plant before, during, and after the shutdown of the nuclear power plant during two periods. In this study, 369 macrobenthic fauna species were collected, and their mean density was 1,712 ind. $m^{-2}$. The number of species and diversity of macrobenthic fauna decreased with distance from the thermal discharge area, regardless of whether the nuclear plant shutdown or not. Many macrobenthic taxa appeared near the thermal discharge area, but polychaetes species were more prominent in outer areas than at the discharge area. The density of macrobenthic fauna decreased with distance from the thermal discharge area during a plant shutdown in the fall of 2011, but increased, except at two sites, near the discharge area in the winter of 2012. Cluster analysis indicated that the spatial distribution of the macrobenthic community changed in areas near the nuclear power plant after a shutdown period; that is, the station group I, in areas near the nuclear power plant, became narrower after the shutdown, but it recovered to previously occupied areas after the nuclear power plant began operating again. Opportunistic species, such as the polychaetes Lumbrineris longifolia (= Scoletoma longifolia) and Mediomastus californiensis, which were present in high densities near thermal discharge areas, decreased after the shutdown but recovered after the plant re-opened. The number of species and diversity of the macrofauna and the density of dominant species showed a significant correlation with temperature, except in winter periods. The results of this study revealed that changes in the amount of thermal discharge before and after the shutdown of a nuclear power plant could exert an influence on the structure of macrobenthic community within the thermal discharge areas depending on the season.

유량조절이 가능한 사이펀 여수로 수리모형실험 (Hydrualic Model Test for Siphon Spillway Capable of Controlling Discharge)

  • 정재상;장은철;이창훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.43-47
    • /
    • 2019
  • 본 연구에서는 수리모형실험을 통해 사이펀 여수로에 장착된 air slot의 방류량 조절 능력을 검토하였다. air slot의 단면 형상으로 원호 및 직사각형 형상을 채택하였으며, 개구부 면적을 조절할 수 있게 하였다. air slot이 장착된 경우 사이펀 관 내부에 공기와 물이 혼합된 복잡한 흐름이 발생하였다. air slot이 장착된 사이펀 여수로에서 저수지 내측 수위가 상승할 때와 하강할 때 동일한 수위에서 동일한 유량이 계측되었다. air slot의 무차원 개구부 면적이 증가할수록 무차원 방류량은 더 서서히 증가하였다. 수리모형실험 결과는 air slot의 면적 조절을 통해 사이펀을 통한 방류량 조절이 가능함을 보여주었다.

  • PDF