• 제목/요약/키워드: discharge area

검색결과 1,549건 처리시간 0.032초

정전분무 방전극을 이용한 습식 전기집진장치의 미세먼지 집진효율 평가 (Evaluation of Particle Collection Efficiency in a Wet Electrostatic Precipitator Using an Electrosprayed Discharge Electrode)

  • 김홍직;김종현;김종호
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.530-537
    • /
    • 2015
  • The wet electrostatic precipitator (wet ESP) is an effective control device which removes submicron particles reentrained in a collection plate and water soluble gas. However, its collection efficiency decreases, as its operation is subject to water-induced distortion of the collection electrode. In order to make up for the limitation, we modified the wet ESP system by installing electrosprayed discharge electrodes. The modified wet ESP system can wash both the collection plate and discharge electrode. As a result, we were able to fabricate a compact wet ESP with a small specific collecting area ($0.18m^2(m^3/min)$) that can accomplish a high collection efficiency of fine particles (97.1%). In addition, the device obtained a relatively low specific corona power of approximately $10W/(m^3/min)$.

Effect of the Freshwater Discharge on Seawater and Sediment Environment in a Coastal Area in Goheung County, South Korea

  • Nguyen, Hoang Lam;Jang, Min-Seok;Cho, Hyeon-Seo
    • 해양환경안전학회지
    • /
    • 제20권3호
    • /
    • pp.270-276
    • /
    • 2014
  • Seasonal characteristics of water and sediment qualities and potential effects of the freshwater discharge from a small tide embankment interior in a coastal area in Goheung county were investigated from May to September in 2012. Chemical oxygen demand values (COD) were mostly higher than 2 mg/L in summer ebb tide, which exceed the standard value of water quality criteria II of acceptable level for aquaculture activities. Nitrogen and phosphorus were found as the limiting nutrients for algae growth in summer and fall and in spring, respectively. Nitrogen was the limiting nutrient for diatom growth in the whole studied period. The sudden high values of COD, ammonia, dissolved inorganic nitrogen (DIN), dissolved inorganic phosphorus (DIP) were found in water sample collected from station 5 which located in front of the tide embankment sluice gate during spring ebb tide. The freshwater discharge form the tide embankment interior maybe affected the survey areas during a short time interval. Mean values of eutrophication index of the surveyed coastal region in spring, summer and fall were all bigger than 1. Water quality was mostly considered at level II which acceptable for aquaculture activities. Sediment quality in this study was generally in the range of standard for fisheries environment.

도시유역의 내수배제를 위한 도시유출모델의 비교 (Comparison of Urban Runoff Models for Interior Drainage in Urban Basin)

  • 최윤영;이영화;지홍기
    • 상하수도학회지
    • /
    • 제14권3호
    • /
    • pp.251-259
    • /
    • 2000
  • In this study, the urban runoff models, ILLUDAS model and SWMM, are analyzed the probable peak discharge and discharge using rainfall distribution by Huff's method at Bum-uh chun area in Taegu city. The probability rainfall and intensity is analyzed by Pearson-III type. The rainfall duration, 90 minutes, is determined by the critical duration computed the maximun peak discharge for some rainfall durations. The peak discharge according to Huff's rainfall distribution types compute in order of type 3, type 4, type2, and type 1, so Huff's 3 type is selected as an adequate rainfall distribution in Bum-uh chun basin. ILLUDAS model and SWMM are shown as good models in Bum-uh chun, but SWMM is computed higher peak discharge than ILLUDAS model, so SWMM is shown as the adequate urban runoff model for the design of interior drainage in urban basin.

  • PDF

논의 배수물꼬의 유량에 관한 기초연구 (A Study on the Outlet Drain Discharge from Paddy Field)

  • 최진규;김현영;손재권
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.134-142
    • /
    • 1997
  • This study was performed to evaluate the drain runoff characteristics from one paddy field, and to provide the basic data required for the determination of flood discharge and unit drainage water for drainage improvement and farmland consolidation. For this purpose, under the assumption that drain discharge from paddy field was similar to outflow of reservoir, runoff model based on storage equation was applied to the experimental field, and simulated results were compared to the measured discharge at weir point. To estimate effective storage volume of paddy field with water depth, 4 regression formula were examined such as linear, exponential, power, and combined. From the observed runoff characteristics, it was shown to be 3.3~16.3${\ell}$/sec in weir discharge, 57.2~98% in runoff ratio, and relative error of simulated result was 3.0~39.4%, 8.5 ~56.0 % for peak flow and runoff ratio, respectively. Curve number by SCS method was calculated as mean value of 96.4 using measured rainfall and runoff data, it was considered relatively high because paddy field has generally flooding depth contrary to the upland watershed area.

  • PDF

연안역의 냉배수 확산모델링 (Diffusion Modelling of Cold Discharge on Coastal waters)

  • 김종규;김종화
    • 수산해양교육연구
    • /
    • 제13권2호
    • /
    • pp.132-145
    • /
    • 2001
  • The cold discharge from LNG(liquefied natural gas) terminal makes the water temperature around the terminal fall down. This temperature reduction may result in serious changes on marine ecosystem of the coastal area. The numerical model experiments of material transport and tidal circulation in the inner bay, Chinhae Bay are investigated in the dispersion of cold discharge from LNG terminal. The condition of ambient water is exposed to tide, tidal current and cold discharge temperature. Simple numerical model experiments highlight the importance of tidal circulation and cold discharge at each case and some results are discussed. The results of this study can be used as the guideline for the site selection of LNG terminals and long-term marine environmental impact assessment.

  • PDF

벽형의 음극 전극과 보조 전극을 갖는 고효율 플라즈마 표시기의 최적 전극 구조에 관한연구 (Optimal cell structure of a wall-cathode and wall auxiliary anode for high performance plasma display panel)

  • 신범제;정희섭;서정현;황기웅
    • 전자공학회논문지D
    • /
    • 제34D권6호
    • /
    • pp.33-42
    • /
    • 1997
  • In this paper, a new structure for a dC plasma display pane(PDP) with a wall-catode and a wall-auxilizry anode has been suggested. The wall-cathode with a sufficient discharge area maximizes the discharge volume. The auxiliary anode surrounding the discharge region makes the effective control of the charged particles possible. We have investigated the cahracteristics of the new cell structure with a 2-dimensional computer simulation and a micro gap discharge system, and compared experimentally with those of previous cell structure. The new cell structure with the wall-cathode and auxiliary wall-anode turned out to have improved luminance, discharge forming time and sustain voltage.

  • PDF

The effect of the cell size on the discharge characteristics of a plasma display panel

  • Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • 제12권1호
    • /
    • pp.29-35
    • /
    • 2011
  • In this study, plasma display panels with three different cell volumes were prepared by changing the spaces between the vertical barrier ribs into two and three times the reference structure. The discharge gap and area of the segmented ITO electrode were the same for the three cases, and Ne.20%Xe gas was used. The luminance and luminance efficiency were measured using applied voltage variations. The time evolution and intensity distribution of the infrared, which are related to the vacuum ultraviolet, were observed via intensified, charged, coupled device, and the visible-light intensity profiles were observed using PR-900 to analyze the discharge phenomena in the discharge cell.

산화된풀리에틸렌의 부분방전 특성 (The Partial Discharge Properties of Oxidized Polyethylene)

  • 이현수;한상옥
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.802-808
    • /
    • 1992
  • To investigate degradation procedure and life time of the oxidized PE and the unoxidized PE, alternative voltage is applied to the CIGRE Method-II (CM-II) electrode system, which is loaded artificial void, and measures the distribution of partial discharging generation. From the results, the samples etched by oxidation had wide degradation area of dielectric strength. Furthermore, discharge starting voltage was shifted to low voltage, the discharge generation frequency was high and consequently, the quantity of mean charge becomes small. Also, life time of the oxdized sample is shortened according as the oxidation time is longer.

  • PDF

비대칭 전극구조가 교류형 기체 방전의 발광효율에 미치는 영향 (The Effect of Asymmetric Electrode Structure on the Emission Efficiency in ac Gas Discharge)

  • 서정현;신범재
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.732-738
    • /
    • 2015
  • In ac discharge, emission efficiency shows an time-varying characteristics during discharge. The phenomenon is caused by the potential distribution changes during the discharge, which indicates that a specific potential distribution can contribute to a high improvement of the emission efficiency. To create an artificial environment for a potential distribution favorable to emission efficiency, we used the asymmetric electrode structure and proved the capability. Our results showed that the ratio of the area of anode to cathode became larger, the emission efficacy was greatly improved.

미소 전극 간격을 갖는 방전장치에서의 방전특성 연구 (The study of the characteristics of micro-gap discharge)

  • 서정현;신범재;정희섭;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-269
    • /
    • 1994
  • Various types of plasma display panels(PDPs) have been developed to realize the flat panel display device. But, many of its characteristics must be improved before it can be commercialized. In order to investigate tile characteristics of micro discharge in a PDP ceil, we have constructed a micro-gap discharge system whose electrode gap can be adjustable between $100-1000{\mu}m$ within $0.1{\mu}m$ accuracy. We measured the minimum sustain voltage, current, delay time of discharge while changing parameters(electrode gap distance, electrode surface area, pressure) which influence discharge characteristics.

  • PDF