• Title/Summary/Keyword: disc

Search Result 3,920, Processing Time 0.03 seconds

Lumbar Epidural Varix Mimicking Disc Herniation

  • Bursali, Adem;Akyoldas, Goktug;Guvenal, Ahmet Burak;Yaman, Onur
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.410-413
    • /
    • 2016
  • Lumbar radiculopathy is generally caused by such well-recognized entity as lumbar disc herniation in neurosurgical practice; however rare pathologies such as thrombosed epidural varix may mimic them by causing radicular symptoms. In this case report, we present a 26-year-old man with the complaint of back and right leg pain who was operated for right L4-5 disc herniation. The lesion interpreted as an extruded disc herniation preoperatively was found to be a thrombosed epidural varix compressing the nerve root preoperatively. The nerve root was decompressed by shrinking the lesion with bipolar thermocoagulation and excision. The patient's complaints disappeared in the postoperative period. Thrombosed lumbar epidural varices may mimic lumbar disc herniations both radiologically and clinically. Therefore, must be kept in mind in the differential diagnosis of lumbar disc herniations. Microsurgical techniques are mandatory for the treatment of these pathologies and decompression with thermocoagulation and excision is an efficient method.

Local Heat Transfer Measurement and Numerical Analysis in the Ventilated Disc Brake with Semi-Cylindrical Grooves (반 실린더형 홈을 가진 벤틸레이티드 디스크 브레이크에서의 국소열전달 측정 및 수치 해석)

  • Lee Dae-Hee;Park Sung-Bong;Lim Chang-Yul;Kim Heung-Seop;Lee Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.587-593
    • /
    • 2006
  • A ventilated disc brake having semi-cylindrical grooves has been proposed to improve the thermal judder by way of heat transfer enhancement. The local heat transfer coefficients were measured in the flow passage of disc brake. These measured local heat transfer data were utilized to do the finite element numerical analysis which predicts the maximum temperatures on the disc brake. The results show that the maximum temperatures on the disc surface with semi-cylindrical grooves are approximately 35.2% lower than those without them.

An Experimental Study of Disc Warping in Slim-type Optical Disc Drive (Slim-type 광학식 정보저장기기에서의 디스크 변형에 관한 실험적 연구)

  • Lee, Jae-Sung;Rhim, Yoon-Chul
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.676-681
    • /
    • 2003
  • In this paper, we investigated the disc warping in high-speed slim-type optical disc drive. Recently, the information storage devices are increasing track density and higher rotation speed to enhance their recording capacity and their data transfer rate. Generally, ODD used in the Lap-top Computer has small inner space. So, the flow instability of inner space is rapidly increased as its higher rotation speed. An extreme case, the flow instability causes the malfunction of readout at pick-up of drives. The experiments and numerical analysis were carried out for several cases, the result shows the influence of airflow to the disc warping.

  • PDF

Stress Redistributions due to the Shape of Sliding Core and Applied Load Core in the Artificial Intervertebral Disc (인공추간판 슬라이딩 코어의 형상과 하중모드에 따른 응력 재분포)

  • Kang Bong-Su;Kim Cheol-Woong
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.515-516
    • /
    • 2006
  • The goal of total disc replacement is to restore pain-free mobility to a diseased functional spinal unit, by replacing the degenerated disc with a mobile bearing prosthesis. SB Charite III is named commercial product as the Artificial Intervertebral Disc (AID). SB Charite III consists of sliding core and endplate made by Ultra-high Molecular Weight Polyethylene (UHMWPE) and cobalt chrome alloy, respectively. To evaluate the effect of von-Mises stress in AID, and three-dimensional finite element model of AID analysis was preformed for four different loading types of sliding core. Consequently, endplate was compared with a compressive preload at 400N and flexion moment at $3{\sim}9Nm4. Therefore, this research has obtained result that von-Mises stress of sliding core in AID disc by radius curvature.

  • PDF

A Study on the Thermal Behaviour of Automotive Disc Brakes Using FEA and Dynamometer (FEA와 다이나모메터를 이용한 자동차 디스크 브레이크의 열적 거동에 관한 연구)

  • 박범식;손영지;장성규;전언찬
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.45-50
    • /
    • 2000
  • While braking cars, a large amount of energy is taken into the brake system in a short period of time. This leads to some problems ; cracking of the disc, non-uniform wear of pad and disc, fade. Thus it is important to measure the contact thermal behaviour precisely between disc and pad. The measurements must be considered to design the brake system. The paper describes methods to analysis the problem of the thermal behavior on the ventilated disc with ANSYS-a program of FEA and a brake dynamometer. According to this way, the paper can present the error between the data by the dynamometer and the results of analysis by ANSYS.

  • PDF

A Study on the Measuring Method of Disc Braking Force for HSR 350x (한국형 고속전철의 디스크 제동력 측정 방법에 관한 연구)

  • Kim, Seog-Won;Kim, Young-Guk;Park, Tae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.244-251
    • /
    • 2004
  • In general, the braking system of high speed train has an important role for the safety of the train. To stop safely the train at its pre-decided position, it is necessary to combine properly the various brakes. Korean high speed train (HSR 350x) has adopted a combined electric and mechanic (friction) braking system. Electric brakes are consist of rheostatic brake, regenerative brake and eddy current brake and mechanical brakes are composed of disc brake, wheel disc brake and tread brake. In this paper, the measuring method that can take a measurement of the braking forces for disc brake and wheel disc brake has been suggested and we have verified that this method is valid through on-line test of HSR 350x.

Finite Element Analysis of a Rotating Disc with a Corner Crack Originating at the Bolt Holes (회전체 원판의 볼트구멍에 존재하는 모서리균열의 유한요소해석)

  • 한상배;이진호;김영진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3055-3062
    • /
    • 1993
  • The objective of this paper is to obtain stress intensity factor solutions for a corner crack originating at bolt holes in a rotating disc. Initially two-dimensional finite element analyses of a rotating disc with bolt holes are performed to determine the maximum stress region. Subsequently three-dimensional finite element analyses of a rotating disc with a corner crack originating at the bolt holes are performed with a variety of crack geometries. According to the numerical results, the maximum stress intensity factor, with an increase in crack depth ratio, was observed at the surface of the plate due to the interference effect of corner crack and disc bore.

Correlation between internal derangement and osteoarthrosis in the temporomandibular joint using magnetic resonance imaging

  • Song Haeng-Un;Choi Sun-Young;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.221-225
    • /
    • 2002
  • Purpose: To evaluate the relationship between internal derangement and osteoarthrosis in the temporomandibular joint (TMJ) using magnetic resonance imaging (MRI). Materials and Methods: One hundred and six MR images of TMJs in 53 patients were evaluated. Disc displacements and osseous changes of the TMJs were assessed. Lateral and rotational disc displacements were also evaluated on coronal images. Results: No significant differences in the frequency of osseous changes of the TMJs between disc displacement with reduction and disc displacement without reduction groups were found. The erosion of the condylar head and the sclerosis of the articular eminence were more frequent in the internal derangement group than in the no disc displacement group. The flattening was the most frequently observed osseous change of both the condylar head and articular eminence. Conclusion : The relationship between internal derangement and osteoarthrosis is obscure, but it is thought that both disorders adversely affect each other.

  • PDF

Magnetic Resonance Imaging Follow-up Study on Two Cases of Lumbar intervertebral Disc Sequestration Patients Treated with Oriental Medicine Treatment (한방 요법으로 호전된 부골화된 요추 추간판 탈출증 환자에서의 영상의학적 변화)

  • Lee, Ki-Su;Hong, Kwon-Eui
    • Journal of Pharmacopuncture
    • /
    • v.14 no.3
    • /
    • pp.99-107
    • /
    • 2011
  • Objectives : The purpose of this study is to report the image changes of two cases of Lumbar intervertebral Disc Sequestration after oriental medical treatment. Methods : We examined 2 patients with Lumbar intervertebral Disc Sequestration who showed changes on MRI images before/after the treatment. And we assessed clinical symptoms by using numeric rating scale(NRS) and straight leg raising test(SLRT). Results & Conclusions : In this study, the first MRI examination of Lumbar intervertebral Disc Sequestration patients was performed at the first visit and re-examination of MRI was done after treatment. In each case, the size of the disc sequestration was considerably reduced in MRI image. And both patients represented effective improvment in NRS score and SLRT test angle.

The Spontaneous Resorption of Herniated Lumbar Disc -A case report- (요추 추간판탈출증의 자연적 흡수 -증례 보고-)

  • Kim, Young Hoon;Moon, Dong Eon;Park, Chong Min;Yoon, Jae Won
    • The Korean Journal of Pain
    • /
    • v.18 no.1
    • /
    • pp.56-59
    • /
    • 2005
  • The most effective treatment methods for a herniated lumbar disc remain questionable. This report follows the patients course, from the onset of pain through the completion of the non-surgical treatment, and shows that a lumbar herniated disc, with radiculopathy, can be successfully treated with a non-surgical approach. This report discusses the possible explanations for disc resorption: retraction into the intervertebral space, dehydration/shrinkage and resorption due to an inflammatory reaction. A non-surgical approach can be an effective treatment option for a herniated lumbar disc.