• Title/Summary/Keyword: disaster and safety data

Search Result 689, Processing Time 0.03 seconds

Effects of the Questionnaire and Radioactivity Measurement of Fishery from the Fukushima Nuclear Disaster (후쿠시마 원자력 재해 이후 수산물의 방사능 측정 및 설문 조사)

  • Kim, Myung Jun;Kang, Seok Min;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • March 11, 2011 Fukushima nuclear power plant accident has occurred, the last four years, his is the current state of anxiety remains on the consumer. Therefore, 2015 the current progress continues to have continued research for the purpose of resolving the insecurity of fishery in the country. We measured the radiation of the origin of fishery products, by 2015, research was carried out through a number of references to get additional data or studies that influence this to some degree. Create a consumer and one for the seller for the survey to find out the thoughts of both consumers and sellers on fisheries was to create the statistics by direct survey in 2014 year survey meter using PM1405 equipment dynamics of several species of aquatic origin in accordance with the (Taiwan, China, Russia), mackerel, pomfret, hairtail, saury, shrimp, squid measurements of radiation were investigated. The measurement in 2014 was $0.043{\sim}0.073{\mu}Sv/h$. The seller influenced the survey (90%) on fishery products sales, consumer safety, without this fishery (90%), radioactive contamination very high (28%) and the polarization was not as nearly 72%. The study of the stability of the radiation determined by the radiation levels of the aquatic marine products in a comparison the radiation levels result was determined in ICRP below the standard value (1 mSv/y).

Development of Multi-Site Daily Rainfall Simulation Based on Homogeneous Hidden Markov Chain Model Coupled with Chow-Liu Tree Structures (Chow-Liu Tree 모형과 동질성 Hidden Markov Model을 연계한 다지점 일강수량 모의기법 개발)

  • Kwon, Hyun-Han;Kim, Tae Jeong;Kim, Oon Ki;Lee, Dong Ryul
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.10
    • /
    • pp.1029-1040
    • /
    • 2013
  • This study aims to develop a multivariate daily rainfall simulation model considering spatial coherence across watershed. The existing Hidden Markov Model (HMM) has been mainly applied to single site case so that the spatial coherences are not properly addressed. In this regard, HMM coupled with Chow-Liu Tree (CLT) that is designed to consider inter-dependences across rainfall networks was proposed. The proposed approach is applied to Han-River watershed where long-term and reliable hydrologic data is available, and a rigorous validation is finally conducted to verify the model's capability. It was found that the proposed model showed better performance in terms of reproducing daily rainfall statistics as well as seasonal rainfall statistics. Also, correlation matrix across stations for observation and simulation was compared and examined. It was confirmed that the spatial coherence was well reproduced via CLT-HMM model.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Analysis of Structural Types and Design Factors for Fruit Tree Greenhouses (과수재배용 온실의 구조유형과 설계요소 분석)

  • Nam, Sang-Woon;Ko, Gi-Hyuk
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • In order to provide basic data for the development of a controlled environment cultivation system and standardization of the structures, structural status and improvement methods were investigated for the fruit tree greenhouses of grape, pear, and peach. The greenhouses for citrus and grape cultivation are increasing while pear and persimmon greenhouses are gradually decreasing due to the advance of storage facilities. In the future, greenhouse cultivation will expand for the fruit trees which are more effective in cultivation under rain shelter and are low in storage capability. Fruit tree greenhouses were mostly complying with standards of farm supply type models except for a pear greenhouse and a large single-span peach greenhouse. It showed that there was no greenhouse specialized in each species of fruit tree. Frame members of the fruit tree greenhouses were mostly complying with standards of the farm supply type model or the disaster tolerance type model published by MIFAFF and RDA. In most cases, the concrete foundations were used. The pear greenhouse built with the column of larger cross section than the disaster tolerance type. The pear greenhouse had also a special type of foundation with the steel plate welded at the bottom of columns and buried in the ground. As the results of the structural safety analysis of the fruit tree greenhouses, the grape greenhouses in Gimcheon and Cheonan and the peach greenhouses in Namwon and Cheonan appeared to be vulnerable for snow load whereas the peach greenhouse in Namwon was not safe enough to withstand wind load. The peach greenhouse converted from a vegetable growing facility turned out to be unsafe for both snow and wind loads. Considering the shape, height and planting space of fruit tree, the appropriate size of greenhouses was suggested that the grape greenhouse be 7.0~8.0 m wide and 2.5~2.8 m high for eaves, while 6.0~7.0 m wide and 3.0~3.3 m of eaves height for the pear and peach greenhouses.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Development of a Storage Level and Capacity Monitoring and Forecasting Techniques in Yongdam Dam Basin Using High Resolution Satellite Image (고해상도 위성자료를 이용한 용담댐 유역 저수위/저수량 모니터링 및 예측 기술 개발)

  • Yoon, Sunkwon;Lee, Seongkyu;Park, Kyungwon;Jang, Sangmin;Rhee, Jinyung
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1041-1053
    • /
    • 2018
  • In this study, a real-time storage level and capacity monitoring and forecasting system for Yongdam Dam watershed was developed using high resolution satellite image. The drought indices such as Standardized Precipitation Index (SPI) from satellite data were used for storage level monitoring in case of drought. Moreover, to predict storage volume we used a statistical method based on Principle Component Analysis (PCA) of Singular Spectrum Analysis (SSA). According to this study, correlation coefficient between storage level and SPI (3) was highly calculated with CC=0.78, and the monitoring and predictability of storage level was diagnosed using the drought index calculated from satellite data. As a result of analysis of principal component analysis by SSA, correlation between SPI (3) and each Reconstructed Components (RCs) data were highly correlated with CC=0.87 to 0.99. And also, the correlations of RC data with Normalized Water Surface Level (N-W.S.L.) were confirmed that has highly correlated with CC=0.83 to 0.97. In terms of high resolution satellite image we developed a water detection algorithm by applying an exponential method to monitor the change of storage level by using Multi-Spectral Instrument (MSI) sensor of Sentinel-2 satellite. The materials of satellite image for water surface area detection in Yongdam dam watershed was considered from 2016 to 2018, respectively. Based on this, we proposed the possibility of real-time drought monitoring system using high resolution water surface area detection by Sentinel-2 satellite image. The results of this study can be applied to estimate of the reservoir volume calculated from various satellite observations, which can be used for monitoring and estimating hydrological droughts in an unmeasured area.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

Development of Economic Analysis Indicators and Case Scenario Analysis for Decision-making support for Off-Site Construction Utilization of Apartment Houses (OSC 활용 의사결정 지원을 위한 경제성 분석 지표 개발 및 사례 시나리오 분석 - 공동주택 PC공법을 중심으로 -)

  • Yun, Won-Gun;Bae, Byung-Yun;Shin, Eun-Young;Kang, Tai-Kyung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.6
    • /
    • pp.24-35
    • /
    • 2023
  • Recently, the Ministry of Land, Infrastructure and Transport presented the '6th Construction Technology Promotion Basic Plan' and 'Smart Construction Revitalization Plan (2022.7.20)'. Off-Site Construction (OSC), which involves construction and production of PC (Precast Concrete) and Modular, etc., has advantages in shortening the construction period, reducing costs, improving quality, reducing construction waste, and reducing safety accidents. However, the construction cost is high compared to the traditional RC construction method, which has hindered its utilization and spread. In this study, OSC utilization was improved. An economic analysis indicator and methodology that can support decision-making in the planning and design stages for multi-unit housing were proposed. The factors used in the economic analysis of OSC (based on the PC method) of apartment houses were reviewed. As for the indicators used in the cost and benefit section, 'Construction Period', 'Disaster Occurrence', 'Waste Generation', and 'Greenhouse gas Emission', which reflect the technical advantages of OSC, were derived. In addition, a scenario analysis was conducted based on actual apartment housing case data for the presented economic analysis indicators and benefit calculation standards. The level of benefit that offsets the difference between the existing RC construction method and the construction cost was reviewed. In future studies, it will be necessary to conduct additional case studies to apply the measurement criteria for detailed indicators and supplement the benefit indicators.

Changing Trends of Climatic Variables of Agro-Climatic Zones of Rice in South Korea (벼 작물 농업기후지대의 연대별 기후요소 변화 특성)

  • Jung, Myung-Pyo;Shim, Kyo-Moon;Kim, Yongseok;Kim, Seok-Cheol;So, Kyu-Ho
    • Journal of Climate Change Research
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • In the past, Korea agro-climatic zone except Jeju-do was classified into nineteen based on rice culture by using air temperature, precipitation, and sunshine duration etc. during rice growing periods. It has been used for selecting safety zone of rice cultivation and countermeasures to meteorological disasters. In this study, the climatic variables such as air temperature, precipitation, and sunshine duration of twenty agro-climatic zones including Jeju-do were compared decennially (1970's, 1980's, 1990's, and 2000's). The meteorological data were obtained in Meteorological Information Portal Service System-Disaster Prevention, Korea Meteorological Administration. The temperature of 1970s, 1980s, 1990s, and 2000s were $12.0{\pm}0.14^{\circ}C$, $11.9{\pm}0.13^{\circ}C$, $12.2{\pm}0.14^{\circ}C$, and $12.6{\pm}0.13^{\circ}C$, respectively. The precipitation of 1970s, 1980s, 1990s, and 2000s were $1,270.3{\pm}20.05mm$, $1,343.0{\pm}26.01mm$, $1,350.6{\pm}27.13mm$, and $1,416.8{\pm}24.87mm$, respectively. And the sunshine duration of 1970s, 1980s, 1990s, and 2000s were $421.7{\pm}18.37hours$, $2,352.4{\pm}15.01hours$, $2,196.3{\pm}12.32hours$, and $2,146.8{\pm}15.37hours$, respectively. The temperature in Middle-Inland zone ($+1.2^{\circ}C$) and Eastern-Southern zone ($+1.1^{\circ}C$) remarkably increased. The temperature increased most in Taebak highly Cold zone ($+364mm$) and Taebak moderately Cold Zone ($+326mm$). The sunshine duration decreased most in Middle-Inland Zone (-995 hours). The temperature (F=2.708, df=3, p= 0.046) and precipitation (F=5.037, df=3, p=0.002) increased significantly among seasons while the sunshine duration decreased significantly(F=26.181, df=3, p<0.0001) among seasons. In further study, it will need to reclassify agro-climatic zone of rice and it will need to conduct studies on safe cropping season, growth and developing of rice, and cultivation management system etc. based on reclassified agro-climatic zone.