• Title/Summary/Keyword: direction code

Search Result 483, Processing Time 0.029 seconds

On the Fracture Behaviour of the Concrete Gravity Dam Subjected to Water Pressure at the Crack Faces (균열면에 수압을 받는 중력식 콘크리트 댐의 파괴거동에 관한 연구)

  • 장희석
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.189-198
    • /
    • 1996
  • The fracture behaviour of concrete gravity dam mainly due to uplift pressure acting at the crack face was studied. Triangular type and parabolic type distribution of the uplift pressure including uniform type were first considered in case of calculating stress intensity factor(SIF) by the surface integral method. Second, the directions of crack propagation according to the uplift pressure distribution were pursued by FRANC(FRacture ANalysis Code). Third, critical crack lengths according to the uplift pressure distribution under the overflow depth were calculated. The SIF values obtained from the surface integral method were compared with those by FRANC and relatively good agrements could be obtained between both of them. And it could be seen that the direction of crack propagation in case of triangular pressure distribution was a little benter to the dam base than the one by the uniform type. Maximum critical crack lengths under the overflow depth were obtained at about 2/5-1/2 of the dam height.

  • PDF

Wind characteristics in the high-altitude difference at bridge site by wind tunnel tests

  • Zhang, Mingjin;Zhang, Jinxiang;Li, Yongle;Yu, Jisheng;Zhang, Jingyu;Wu, Lianhuo
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.547-558
    • /
    • 2020
  • With the development of economy and construction technology, more and more bridges are built in complex mountainous areas. Accurate assessment of wind parameters is important in bridge construction at complex terrain. In order to investigate the wind characteristics in the high-altitude difference area, a complex mountain terrain model with the scale of 1:2000 was built. By using the method of wind tunnel tests, the study of wind characteristics including mean wind characteristics and turbulence characteristics was carried out. The results show: The wind direction is affected significant by the topography, the dominant wind direction is usually parallel to the river. Due to the sheltering effect of the mountain near the bridge, the wind speed and wind attack angle along the bridge are both uneven which is different from that at flat terrain. In addition, different from flat terrain, the wind attack angle is mostly negative. The wind profiles obey exponential law and logarithmic law. And the fitting coefficient is consistent with the code which means that it is feasible to use the method of wind tunnel test to simulate complex terrain. As for turbulence characteristics, the turbulence intensity is also related to the topography. Increases sheltering effect of mountain increases the degree of breaking up the large-scale vortices, thereby increasing the turbulence intensity. Also, the value of turbulence intensity ratio is different from the recommended values in the code. The conclusions of this study can provide basis for further wind resistance design of the bridge.

Strength Safety Evaluation of Composite Pressure Container for Hydrogen Fuel Tanks (수소연료탱크용 복합소재 압력용기에 관한 강도안전성 평가연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.30-34
    • /
    • 2011
  • This paper presents a strength safety evaluation of composite pressure container for hydrogen fuel tanks with a storage capacity of 104 liter and 70MPa pressure. The carbon fiber composite container is manufactured by an aluminum liner of Al6061-T6 and composite multi-layers of hoop winding layer in circumferential direction, $12^{\circ}C$ inclined winding layer and $70^{\circ}C$winding layer in helical direction respectively. The FEM results on the strength safety of composite fuel tanks were evaluated with a criterion of design safety of US DOT-CFFC and KS B ISO 11119-2 codes. The FEM computed results indicate that the proposed design model of 104 liter composite container is safe based on two strength safety codes. But, the computed results of carbon fiber fuel tanks based on US DOT-CFFC code is safer compared with that of KS B ISO 11119-2. Thus the hydrogen gas pressure container of 70MPa may be evaluated and designed by US DOT-CFFC code for more strength safety.

Numerical Simulations of Water Circulation and Pollutant Transport near a Coastal Area of Wolsung NPPs (월성원전 연안역 해수유동 및 오염물 이동 수치실험)

  • Park, Geon-Hyeong;Kim, Ki-Chul;Min, Byung-Il;Lee, Jung-Lyul;Suh, Kyung-Suk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.4
    • /
    • pp.255-262
    • /
    • 2012
  • Numerical simulations were performed to evaluate the dispersion characteristics of the pollutant around a Wolsung coastal area at located nuclear power plants. Numerical experiments by using EFDC(Environmental Fluid Dynamics Code) showed good agreements by comparison with the time series and harmonic analysis of the tidal elevations. The released pollutants moved in north direction at flood tide and in south direction at ebb tide. The calculated salinity and temperatures showed good agreements with the observed results by NFRDI(National Fisheries Research & Development Institute). The water circulation due to the variations of the temperature, salinity and tidal components were analyzed to estimate the dispersion characteristics of the pollutant.

A Dynamic Channel Allocation Employing Smart Antenna to Resolve a Crossed Time-slot Problem in TD-SCDMA (TD-SCDMA에서 셀 간 교차 타임-슬롯 문제 해결을 위한 스마트 안테나 기반의 동적 채널 할당 방안)

  • Kim, Eun-Heon;Park, Jae-Hyun;Kim, Duk-Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12A
    • /
    • pp.1276-1285
    • /
    • 2007
  • Since the TD-SCDMA (Time Division-Synchronous Code Division Multiple Access) system is based on TDD (Time Division Duplexing), the uplink and downlink can be allocated asymmetrically according to the traffic e.g. Web browsing. Although this asymmetric allocation can increase the frequency utilization, it may cause time slot opposing, which implies the time slot is assigned in opposing direction between cells. The time slot opposing can generate significant interference between cells, which results in severe performance degradation. In the paper, a novel dynamic channel allocation (DCA) is proposed in the TD-SCDMA system, to mitigate the impact of time slot opposing considering smart antenna. When the smart antenna is applied in the system, the inter-cell interference is largely affected by beam pattern and beam direction between neighboring cells. Therefore, the time slot opposing and smart antenna should be considered together in the DCA. The intensive simulations show that the proposed scheme can improve the system capacity compared to the conventional DCA schemes.

Evaluation of Maximum Effective Temperature for Estimate Design Thermal Loads in Steel Box Girder Bridges (강상자형교의 설계온도하중을 위한 최고 유효온도 산정)

  • Lee, Seong-Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.133-139
    • /
    • 2016
  • In order to obtain a reasonable value for the thermal load to use in designs, a bridge specimen of a full-size steel box girder (bridge) was manufactured. The temperature data were measured at 21 points in the bridge specimen and 19 points in the steel box bridge. The steel box bridge specimen was installed in a similar direction to a nearby real one. The maximum effective temperatures in the bridge specimen and bridge were calculated for air temperatures in the range of $24^{\circ}C{\sim}38^{\circ}C$. The maximum effective temperature of the bridge specimen and bridge showed correlations of approximately 93.2% and 87.4%, respectively, compared with the Euro code. The maximum effective temperature calculated in this study was very close to the Euro code and the maximum temperature of the Highway Bridge Design Criteria. When the effective temperature obtained in the study is combined with the highest temperature calculated from the Contour map for each region, the design criteria for the thermal load in domestic bridge design, taking into consideration the characteristics of each region, can be established.

Static Shear Resistance of Cast-In-Place Anchors in Cracked Concrete (균열콘크리트에 매입된 선설치앵커의 정적 전단하중에 대한 저항강도)

  • Park, Yong Myung;Ju, Ho Jung;Kim, Dong Hyun;Kang, Moon Ki;Lee, Jong Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.87-97
    • /
    • 2015
  • In this study, an experimental study was performed to evaluate the concrete breakout strength of cast-in-place(CIP) anchors in cracked concrete under static shear loading. The CIP anchors involved in this study were 30mm in diameter with an edge distance of 150mm and an embedment length of 240mm. The experiment was carried out for two specimens in uncracked concrete and three specimens in cracked concrete orthogonal and parallel to the direction of shear loading, respectively. Compared to the uncracked concrete specimen, cracked specimen orthogonal to the direction of shear loading showed no reduction in the concrete breakout strength and that parallel to the load direction about 91% strength which corresponds to 84% of uncracked concrete strength defined in ACI 318-11. Therefore, the experimental results showed smaller decrease in the shear resistance of CIP anchors in cracked concrete than that specified in ACI code which account for 71% strength of uncracked concrete in cracked concrete.

Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

An Image Management System of Frame Unit on a Hand-held Device Environments (휴대장치 환경을 위한 프레임 단위의 영상 데이터 관리 시스템)

  • Choi, Jun-Hyeog;Yoon, Kyung-Bae;Han, Seung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.29-36
    • /
    • 2008
  • This paper proposes algorithm for the system that can search for an image of a frame unit, and we implement it. A system already inserts in images after generating the cord that mechanical decoding and identification are possible. We are independent of an external noise in a frame unit, and a system to propose at these papers can search for an image recorded by search condition to include recording date, recording time, a recording place or filming course etc. This system is composed by image insertion wealth to insert data to an image to data image code generation wealth, a frame generating data image code you apply a code generation rule to be fixed in order to express to a price to have continued like data entry wealth, GPS locator values and direction price receiving an image signal, image decoding signals and an image search signal to include search condition, and to have continuity from users each of an image. Also, image decoding we decipher about the noise that was already added from the outsides in a telerecording process, a copy process or storage processes inserted in images by real time, and searching image information by search condition. Consequently we implement decoder, and provide the early system that you use, and we easily insert data code among images. and we can search. and maximization can get precision regarding an image search and use satisfaction as we use algorithm to propose at these papers.

  • PDF

ANALYSIS ON FLOW FIELDS IN AIRFLOW PATH OF CONCRETE DRY STORAGE CASK USING FLUENT CODE (FLUENT를 활용한 콘크리트 건식 저장용기 공기유로 내부 유동장 해석)

  • Kang, G.U.;Kim, H.J.;Cho, C.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.47-53
    • /
    • 2016
  • This study investigated natural convection flow behavior in airflow path designed in concrete dry storage cask to remove the decay heat from spent nuclear fuels. Using FLUENT 16.1 code, thermal analysis for natural convection was carried out for three dimensional, 1/4 symmetry model under the normal condition that inlet ducts are 100% open. The maximum temperatures on other components except the fuel regions were satisfied with allowable values suggested in nuclear regulation-1536. From velocity and temperature distributions along the flow direction, the flow behavior in horizontal duct of air inlet and outlet duct, annular flow-path and bent pipe was delineated in detail. Theses results will be used as the theoretical background for the composing of airflow path for the designing of passive heat removal system by understanding the flow phenomena in airflow path.