• Title/Summary/Keyword: direct vector control

Search Result 235, Processing Time 0.029 seconds

Comparison of DTC between two-level and three-level inverters for LV propulsion electric motor in ship (선박 추진용 저압 전동기에 대한 2레벨 및 3레벨 인버터의 직접토크제어 비교)

  • Ki-Tak RYU;Jong-Phil KIM;Yun-Hyung LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.1
    • /
    • pp.71-79
    • /
    • 2024
  • In compliance with environmental regulations at sea and the introduction of unmanned autonomous ships, electric propulsion ships are garnering significant attention. Induction machines used as propulsion electric motor (PEM) have maintenance advantages, but speed control is very complicated and difficult. One of the most commonly used techniques for speed control is DTC (direct torque control). DTC is simple in the reference frame transformation and the stator flux calculation. Meanwhile, two-level and three-level voltage source inverters (VSI) are predominantly used. The three-level VSI has more flexibility in voltage space vector selection compared to the two-level VSI. In this paper, speed is controlled using the DTC method based on the specifications of the PEM. The speed controller employs a PI controller with anti-windup functionality. In addition, the characteristics of the two-level VSI and three-level VSI are compared under identical conditions. It was confirmed through simulation that proper control of speed and torque has been achieved. In particular, the torque ripple was small and control was possible with a low DC voltage at low speed in the three-level VSI. The study confirmed that the application of DTC, using a three-level VSI, contributes to enhancing the system's response performance.

Optimal current angle control method of interior permanent magnet Synchronous Motors (매입형 영구자석 동기전동기의 최적 전류각 제어)

  • 김명찬;김종구;홍순찬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.352-357
    • /
    • 1996
  • Recently, Permanent Magnet Synchronous Motor(PMSM) drives are widely used for industrial applications due to its high efficiency and high power factor control strategy. PMSM generally have two classifications such as the SPMSM(Surface Permanent Magnet Synchronous Motors) and IPMSM(Inter Permanent Magnet Synchronous Motors). IPMSA has economical merits over SPMSM in higher speed range, mechanical robustness, and higher power rate by the geometric difference. The maximum torque operation in IPMSM is realized by the current angle control which is to utilize additional reluctance torque due to a rotor saliency. In traction, spindle and compressor drives, constant power operation with higher speed range are desirable. This is simply achieved in the DC motor drives by the reduction of the field current as the speed is increased. However, in the PMSM, direct control of the magnet flux is not available. The airgap flux can be weakened by the appropriate current angle control to demagnetize. In this paper, the control method of optimal current vector in IPMSM is described in order to obtain the maximum torque or maximum output with the speed and load variations. The applied algorithm is realized by the proto system with torque and speed control Experimental results show this approach is satisfied for the high performance servo applications. (author). 6 refs., 9 figs., 1 tab.

  • PDF

Analysis and Control Parameter Estimation of a Tubular Linear Motor with Halbach and Radial Magnet Array

  • Jang Seok-Myeong;Choi Jang-Young;Cho Han-Wook;Lee Sung-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.154-161
    • /
    • 2005
  • In the machine tool industry, direct drive linear motor technology is an interesting means to achieve high acceleration, and to increase reliability. This paper analyzes and compares the characteristics of a tubular linear motor with Halbach and radial magnet array, respectively. First, the governing equations are established analytically in terms of the magnetic vector potential and two dimensional cylindrical coordinate systems. Then, we derive magnetic field solutions due to the PMs and the currents. Motor thrust, flux linkage and back emf are also derived. The results are shown to be in good conformity with those obtained from the commonly used finite element method. Finally, control parameters are obtained from analytical solutions.

Vector Control of Induction Motor considering Iron Losses (철손을 고려한 유도전동기의 벡터제어)

  • Choi, Jong-Woo;Chung, Dae-Woong;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.285-288
    • /
    • 1996
  • Iron loss is a possible source of performance deterioration, especially for a torque regulation, in field oriented induction machine. In this paper, study on the model of an induction machine with iron losses, a flux estimation strategy, the design of direct and indirect field oriented controller, a precise torque regulation scheme and the determination of a core lost resistance are discussed. Simulation and experimental results are also included and show the effectiveness of the proposed analysis and the proposed control strategy.

  • PDF

Direct Vector Control of SLM using STATOR TAPPED COIL (STATOR TAPPED COlL을 이용한 편측식 선형유도전동기의 직접벡터제어)

  • Im, Dal-Ho;Kwon, Byung-Il;Kim, Chang-Up;Yun, Ho;Im, Hyung-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.692-694
    • /
    • 1992
  • This paper describes a robust flux bonging scheme which utilizes the windings of the machine itself to implement field orientation control of SLIM (Single-sided Linear Induction Motor). By subtracting the voltage across adjacent motor coils of the same phase which are named STATOR TAPPED COIL, a flux signal is obtained which is insensible to stater resister drop at a low speed that exerts a bad Influence on field orientation. The method using STATOR TAPPED COIL has been implemented at SLIM in our laboratory, and experimental results are being scrutinized.

  • PDF

Takagi-Sugeno Fuzzy Controller for Efficiency Optimization of Induction Motor with Model Uncertainties (Takagi-Sugeno 퍼지 제어기를 이용한 불확실성을 포함한 유도전동기의 효율 최적화)

  • Lee, Sun-Young;Yang, Hai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1646_1647
    • /
    • 2009
  • In this paper, Takagi-Sugeno(T-S) fuzzy controller and search method are developed for efficiency optimization of induction motors(IMs). The proposed control scheme consists of efficiency controller and adaptive backstepping controller. A search controller for which information of input of T-S fuzzy controller is included in efficiency controller that uses a direct vector controlled induction motor. A sliding mode observer is designed to estimate rotor flux and an adaptive backstepping controller is used to control of speed of IMs. Simulation results are presented to validate the proposed controller.

  • PDF

Design of Routing Algorithm for SDDC BAS (SDDC BAS에 적합한 라우팅 알고리즘의 설계)

  • Kim, Jeong-Uk;Boo, Chang-Jin;Lee, Yongho;Choi, Yunki;Joung, Jinoo;Kim, Ho-Chan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.11
    • /
    • pp.1045-1050
    • /
    • 2012
  • In this paper, we propose an effective routing protocol that can be particularly applied to SDDC (Sangmyung Direct Digital Controller) BAS. We have used NS (Network Simulator)-2 to simulate the real building for SDDC BAS. The static, session, DV (Distance Vector), and LS (Link State) algorithms are used and the protocols for performance comparison and evaluation are compared with respect to end to end delay, throughput, and routing overhead. The simulation results show that the DV algorithm is effective for SDDC BAS.

Efficiency Optimization with Sliding Mode Observer for Induction Motor (슬라이딩 모드 관측기를 이용한 유도전동기의 효율 최적화)

  • Lee, Sun-Young;Park, Ki-Kwang;Yang, Hai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.74-76
    • /
    • 2009
  • In this paper, search method and sliding mode observer are developed for efficiency optimization of induction motor. The proposed control scheme consists of efficiency controller and adaptive backstepping controller. A search controller for which information of input of fuzzy controller is included in efficiency controller that uses a direct vector controlled induction motor. The search controller is based on the "Rosenbrock" method and finds the flux level at the minimum input power of induction motor. Once this optimal flux level has been determined, this information is utilized to update the rule base of a fuzzy controller A sliding mode observer is designed to estimate rotor flux and an adaptive backstepping controller is also used to compensate for mechanical uncertainties in the speed control of induction motor. Simulation results are presented to validate the proposed controller.

  • PDF

A Study on Boost/Flux-Weakening Controller for Wide Speed Operation Range having Engine and IPMSG for Special Equipment Vehicle (특수차량용 엔진 직결형 IPMSG의 넓은 속도운전 범위를 위한 부스트/약자속 제어기에 관한 연구)

  • Lee, Sang-Geon;Kim, Sung-An;Cho, Yun-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.54-61
    • /
    • 2014
  • This paper proposes a boost/flux-weakening controller (BFWC) for wide speed operation range having engine and interior permanent magnet synchronous generator (IPMSG) for special equipment vehicle. The proposed BFWC exploits direct torque/flux control (DTFC) scheme based on space vector modulation method to control the constant DC voltage output within the entire speed operation range of engine. And, to improve the response characteristics of maximum torque per ampere (MTPA) operation and flux-weakening operation, the MTPA and flux-weakening feed-forward controllers are applied. To estimate feasibility and usefulness of the proposed controller, the simulation and experimental results are compared.

AN OBSERVER-BASED DTC OF INDUCTION MOTORS DRIVEN BY 3-LEVEL INVERTER FOR IMPROVING LOW SPEED OPERATION (3 레벨 인버터로 구동되는 유도전동기 직접 토크제어의 저속운전 성능 개선)

  • Yun, J.H.;Choi, S.K.;Lee, S.H.;Lee, K.B.;Yoo, J.Y.;Song, J.H.;Choi, I.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1030-1032
    • /
    • 2000
  • Direct torque control algorithm for 3-level inverter-fed induction motors is proposed. Conventional selection method of the stator voltage vector shows problems of stator flux drooping phenomenon and undesirable torque control appeared especially at the low, speed operation. To overcome these problems, a proposed method uses intermediate voltage vectors, which are inherently generated in 3-level inverters. An adaptive observer is also employed to estimate some state-variables and motor parameters, which takes a deep effect on the performance of the low speed operation. Simulation and experiment results verify effectiveness of the proposed algorithm.

  • PDF