• 제목/요약/키워드: direct system

검색결과 6,832건 처리시간 0.035초

재생형 증발식 냉각기를 이용한 제습 냉방시스템의 성능해석 (Cycle Simulation of a Desiccant Cooling System with a Regenerative Evaporative Cooler)

  • 이재완;이대영;강병하
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.566-573
    • /
    • 2004
  • Comparison of the cooling performance is provided between the desiccant cool-ing systems incorporating a direct evaporative cooler and a regenerative evaporative cooler, respectively. Cycle simulation is conducted, and the cooling capacity and COP are evaluated at various temperature and humidity conditions. The COP of the system with a regenerative evaporative cooler and the regeneration temperature of 6$0^{\circ}C$ is evaluated 0.65 at the outdoor air condition of 35$^{\circ}C$ and 40% RH. This value is found about 3.4 times larger than that of the system with a direct evaporative cooler. Furthermore, incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in a desiccant dehumidifier that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners.

DDV를 이용한 압력 제어시스템의 강인제어 (Robust Control of Pressure Control System Using Direct Drive Valve)

  • 이창돈;박성환;이진걸
    • 제어로봇시스템학회논문지
    • /
    • 제11권12호
    • /
    • pp.1077-1082
    • /
    • 2005
  • In this paper, it is proposed that the method for constituting pressure control system controlled by Direct Drive Valve (DDV). The DDV has a pressure-feedback-loop itself. It can eliminate non-linearity and uncertainty oi hydraulic system such as uncertain discharge coefficient and change of bulk-modulus. However, the internal feedback-loop can not compensate them perfectly. And fixed gain of the DDV's internal feedback-loop is not proper to apply it through wide pressure range. The steady state error and nonlinear characteristic of transient behaviour is observed in the experiment. So another controller is needed for the desirable performance of the system. To compose the controller, the pressure control system controlled by DDV is modeled mathematically and the parameters of the model are identified using signal-compression method. Then sliding mode controller is designed based on mathematical model. Desirable performance of the pressure control system controlled by DDV is obtained.

TCP/Ethernet방식을 이용한 DLC(Direct Load Control)의 구성 및 부하제어기법 ( I ) (A Configuration of DLC(Direct Load Control) Using TCP/Ethernet Module And Load Control Method ( I ))

  • 김형중;김인수;박규현;차양환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.570-572
    • /
    • 2000
  • In this paper, we present the configuration of Direct Load Control System using TCP/Ethernet Module for the Load Management Europe and America has operated the DLC system by many communication system, and Taiwan, Japan has controlled the cooling load at peak hours of power system. Up to now, Many Researches for the DLC of communication method, so called, pager, power line carrier, ripple control, etc. has advanced. Now, we present new communication method for the DLC using TCP/Ethernet module which is widespread all over the world.

  • PDF

직접 염료 Direct Sky Blue 5B(C. I. Direct Blue 15)의 면에 대한 레독스계에서의 염색 (Dyeing of Cellulose Fabric with C. I. Direct Blue 15 by Redox System)

  • 김광오;김정구;이영희;김경환
    • 한국염색가공학회지
    • /
    • 제5권3호
    • /
    • pp.173-181
    • /
    • 1993
  • Dyeing cotton fabric with direct dye (C. I. Direct Blue 15) by redox sytem of ammonium persulfate as an oxidant and glucose as reductant was studied. It was found that covalent bond between dye and cellulose molecule can be formed by free radical produced by the redox system in the dye bath, which enhanced significantly the color strength. The retained color strength after DMF extraction was much better in the presence than in the absence of the redox sytem. The optimum dyeing condition was 0.028 mol/$\ell$(APS/Glucose each) of redox concentration, 65$^{\circle}C$ of dyeing temperature and 60min of dyeing time. The color variation on the dyed sample had not been observed as a result of fixed ${\lambda}_max$.

  • PDF

푸른들영농조합의 친환경농산물 유통실태와 발전과제 (Marketing Issues of Pureundeul Farming Corporation at Asan City)

  • 김호;윤종열
    • 한국유기농업학회지
    • /
    • 제13권1호
    • /
    • pp.69-84
    • /
    • 2005
  • Pureundeul fanning corporation(PFC) is an cgmplary body of all producer organizations for environmentally friendly agriculture(EFA) in Korea. It is located at Asan in Chungnam and has 301 farmers. They attained more than 10 billion wons as a sale in 2004. And The direct marketing channel of the EFA products is the second logistics center(Asan) ${\to}$ the first logistics center(Gwangju Gyunggi) ${\to}$ local hansalim shops ${\to}$ consumers. It is needed to construct the system of the direct marketing as follows : First, it needs to construct the direct marketing system within the region for EFA products of Asan. Second, the direct shop and suppling area should be enlarged as a way to promote sales with the demand increase of EFA products. Third, an aggressive promotion campaign is be needed for increasing motivation of consumption and understanding of EFA products.

  • PDF

최단전압붕괴점을 계산하는 개선된 직접법 (Improved Direct Method for Computing a Closest Voltage Collapse Point)

  • 남해곤;송충기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.231-234
    • /
    • 1997
  • This paper presents improved direct method for calculating the closest saddle node bifurcation (CSNB) point, which is also applicable to the selection of appropriate load shedding, reactive power compensation point detection. The proposed method reduced dimension of nonlinear equation compared with that of Dobson's direct method. The improved direct method, utilizing Newton Iterative method converges very quickly. But it diverges if the initial guess is not very close to CSNB. So the direct method is performed with the initial values obtained by carrying out the iterative method twice, which is considered most efficient at this time. Since sparsity techniques can be employed, this method is a good choice to a large scale system on-line application. Proposed method has been tested for 5-bus, New England 30-bus system.

  • PDF

컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계 (Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1590-1595
    • /
    • 2003
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

  • PDF

컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계 (Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method)

  • 이성래
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1719-1726
    • /
    • 2004
  • Direct drive servovalve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the DC motor. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

Seismic test of modal control with direct output feedback for building structures

  • Lu, Lyan-Ywan
    • Structural Engineering and Mechanics
    • /
    • 제12권6호
    • /
    • pp.633-656
    • /
    • 2001
  • In this paper, modal control with direct output feedback is formulated in a systematic manner for easy implementation. Its application to the seismic protection of structural systems is verified by a shaking table test, which involves a full-scale building model and an active bracing system as the control device. Two modal control cases, namely, one full-state feedback and one direct output feedback control were tested and compared. The experimental result shows that in mitigating the seismic response of building structures, modal control with direct output feedback can be as effective and efficient as that with full-state feedback control. For practical concerns, the control performance of the proposed method in the presence of sensor noise and stiffness modeling error was also investigated. The numerical result shows that although the control force may be increased, the maximum floor displacements of the controlled structure are very insensitive to sensor noise and modeling error.

AWGN 채널환경에서 Direct-Conversion 수신기의 성능분석에 관한 연구 (A Study on a Performance Analysis of Direct-Conversion Receiver In Additive White Gaussian Noise Channel)

  • 조형래;김철성;박성진
    • 한국정보통신학회논문지
    • /
    • 제5권4호
    • /
    • pp.668-675
    • /
    • 2001
  • 최근, 상업적인 pcs시스템은 매우 발전되어 있으며, 결국 차세대 이동통신은 멀티미디어 서비스를 제공하는 IMT-2000에 의해 실현될 것이다. 그러므로 , 새로운 형태의 수신 시스템 연구가 활발히 진행되고 있고, 이중하나가 Direct conversion 방식이다 Direct conversion은 차세대 이동통신 시스템에 필요한 저전력, 소형, MMIC, 저가에 적합한 방식이다. 이 시스템을 사용할 경우 DC-offset의 문제가 발생하게 된다. DC-offset은 시스템에서 주파수 합성기의 누설신호에 의해 원하는 신호의 증폭을 억압한다. 본 논문에서 DC-offset을 제거하는 방법에 대해 고려한다. DC-offset의 제거법에는 AC-coupling, 대용량 capacitor, DC-feedback loop, DC-free coding의 4가지 방법이 있다. 이중에서 AC-coupling법은 가장 간단하며, DC-feedback법은 최고의 성능을 가진다. AC-coupling법과 DC-feedback법을 HP사의 ADS를 사용하여 시뮬레이션 하였다.

  • PDF