Development of a Hybrid Recognition System Using Biometrics to Manage Smart Devices based on Internet of Things

  • Ban, Ilhak;Jo, Seonghun;Park, Haneum;Um, Junho;Kim, Se-Jin
    • Journal of Integrative Natural Science
    • /
    • v.11 no.3
    • /
    • pp.148-153
    • /
    • 2018
  • In this paper, we propose a hybrid-recognition system to obtain the state information and control the Internet of Things (IoT) based smart devices using two recognitions. First, we use a facial recognition for checking the owner of the mobile devices, i.e., smartphones, tablet PCs, and so on, and obtaining the state information of the IoT based smart devices, i.e., smart cars, smart appliance, and so on, and then we use a fingerprint recognition to control them. Further, in the conventional system, the message of the state and control information between the mobile devices and smart devices is only exchanged through the cellar mobile network. Thus, we also propose a direct communication to reduce the total transmission time. In addition, we develop a testbed of the proposed system using smartphones, desktop computers, and Arduino vehicle as one of the smart devices. We evaluate the total transmission time between the conventional and direct communications and show that the direct communication with the proposed system has better performance.

A Novel Seamless Direct Torque Control for Electric Drive Vehicles

  • Ghaderi, Ahmad;Umeno, Takaji;Amano, Yasushi;Masaru, Sugai
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.449-455
    • /
    • 2011
  • Electric drive vehicles (EDV) have received much attention recently because of their environmental and energy benefits. In an EDV, the motor drive system directly influences the performance of the propulsion system. However, the available DC voltage is limited, which limits the maximum speed of the motors. At high speeds, the inverter voltage increases if the square wave (SW) voltage (six-step operation) is used. Although conventional direct torque control (DTC) has several advantages, it cannot work in the six-step mode required in high-speed applications. In this paper, a single-mode seamless DTC for AC motors is proposed. In this scheme, the trajectory of the reference flux changes continuously between circular and hexagonal paths. Therefore, the armature voltage changes smoothly from a high-frequency switching pattern to a square wave pattern without torque discontinuity. In addition, because multi-mode controllers are not used, implementation is more straightforward. Simulation results show the voltage pattern changes smoothly when the motor speed changes, and consequently, torque control without torque discontinuity is possible in the field weakening area even with a six-step voltage pattern.

Optimal Placement of the Phasor Measurement Units in Power System (전력계통의 페이저 측정기 최적배치)

  • Kim, Jae-Hun;Jo, Gi-Seon;Kim, Hoi-Chul;Shin, Jung-Rin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

Robustness Bounds of the Vertical Take-Off and Landing Aircraft System with Structured Uncertainties

  • Jo, Jang-Hyen
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.459-459
    • /
    • 2000
  • The purpose of this paper is the application of the techniques for the new estimation of robustness for the aircraft systems having structured uncertainties. The basic ideas to analyze the system which is the originally nonlinear is Lyapunov direct theorems. The nonlinear systems have various forms of terms inside the system equations and this investigation is confined in the form of bounded uncertainties. The number of uncertainties will be the degree of freedoms in the calculation of the robust stability regions called the robustness bounds. This proposition adopts the theoretical analysis of the Lyapunov direct methods, that is, the sign properties of the Lyapunov function derivative integrated along finite intervals of time, in place of the original method of the sign properties of the time derivative of the Lyapunov function itself. This is the new sufficient criteria to relax the stability condition and is used to generate techniques for the robust design of control systems with structured perturbations. Using this relaxing stability conditions, in this paper, the quadratic form of Lyapunov function is utilized. In this paper, the practical system of vertical take-off and landing (VTOL) aircraft is analyzed with the proposed stability criteria based upon the Lyapunov direct method. The application of numerical procedures can prove the improvements in estimations of robustness with structured uncertainties. The applicable aircraft system is assumed to be linear with time-varying with nonlinear bounded perturbations.

  • PDF

Direct Patterning of 3D Microstructures on an Opaque Substrate Using Nano-Stereolithography (나노 스테레오리소그래피 공정을 이용한 불투명 기판에서의 3차원 마이크로 형상 제작 방법에 관한 연구)

  • Son, Yong;Lim, Tae-Woo;Ha, Cheol-Woo;Yang, Dong-Yol;Jung, Byung-Je;Kong, Hong-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.93-99
    • /
    • 2010
  • A nano-stereolithography is the direct patterning process with a nanoscale resolution using twophoton absorption induced by a femtosecond laser. However, in the majority of the works, the fabrication of 3D microstructures have been done only onto transparent glass due to the use of an oil immersion objective lens for achieving a high resolution. In this work, the coaxial illumination and the auto-focusing system are proposed for the direct patterning of nano-precision patterns on an opaque substrate such as a silicon wafer and a metal substrate. Through this work, 3D polymer structures and metallic patterns are fabricated on a silicon wafer using the developed process.

A Study on the Lightning Overvoltage Analysis and Lightning Surge Protection Methods in Underground Distribution System (지중배전계통의 뇌과전압 해석 및 뇌써지 보호방안에 관한 연구)

  • Kim, Sang-Kuk;Jung, Chae-Kyun;Lee, Jong-Beom;Ha, Dong-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.558-560
    • /
    • 2003
  • The effects of surge arresters for protection of transmission systems against direct lightning strokes have already been investigated using the digital simulation program EMTP. Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. This paper analyzes the overvoltages on underground cable system against direct lightning strokes to the overhead ground wire using the digital simulation. The effects of lightning protection methods, such as lowering the grounding resistance and installing the surge arrester, for preventing overvoltages on underground cable system caused by direct lightning strokes to the overhead ground wire is investigated. Several schemes have been proposed to protect underground cables. This paper summarizes the main results of a study aimed at analysis of lightning overvoltages in variety underground feeders protected by metal-oxide arresters. This study will provide insulation coordination methods for reasonable system design in 22.9kV underground cable system.

  • PDF

New reliquefaction system of Boil-Off-Gas by LNG cold energy (LNG냉열이용 BOG 재액화긍정 해석연구)

  • 윤상국;최형식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.256-263
    • /
    • 2002
  • The Boil-Off-Gases(BOG) in the LNG production terminal are continuously generated during the unloading, storage and supply processes by the heat penetration. In order to use these gases as useful fuel, the reliquefaction process should be installed to put the reliquefied BOG in the main LNG supply line before the secondary pump in terminal. The current reliquefaction method of BOG in LNG terminal is the direct contact one between LNG and BOG in the absorption column. But the system has severe disadvantage, which is the 10 times of LNG circulation needed for unit mass of BOG reliquefaction. It causes, therefore, high power consumption of LNG circulation pump and excessive city-gas supply, even if short demand of NG is needed in the summer time. In this paper, the new reliquefaction system of BOG by using LNG cold energy with indirect contact in precooler was suggested and analysed. The result showed new indirect contact method of BOG reliquefaction system between LNG cold energy and BOG is much more effective than the current direct contact one because of only about 1.3 times of LNG circulation needed and higher energy saving by pump power reduction.

Analyzing Stability of Jeju Island Power System with Modular Multilevel Converter Based HVDC System

  • Quach, Ngoc-Thinh;Lee, Do Heon;Kim, Ho-Chan;Kim, Eel-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • This paper proposes the installation of a new modular multilevel converter based high-voltage direct current (MMC-HVDC) system to connect between mainland and Jeju island power systems in Korea in 2020. The purpose is to combine with two old line-commutated converters (LCC)-based HVDC system to achieve a stability of the Jeju island power system. The operation of the overall system will be analyzed in three cases: (i) wind speed is variable, (ii) either one of the LCC-HVDC systems is shutdown because of a fault or overhaul, (iii) a short circuit fault occurs at the mainland side. The effectiveness of the proposed control method is confirmed by the simulation results based on a PSCAD/EMTDC simulation program.

Development of a Seeder Monitoring System (파종기용 파종 감시 장치 개발)

  • 김대호;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.21 no.3
    • /
    • pp.306-314
    • /
    • 1996
  • A seeder monitoring system was developed to solve the problems of mis-sowing and tube clogging in direct seeding machines, which have been one of the factors that reduce the performance of sowing operations. The system consisted of photo sensors, air nozzles, an air compressor, and a one-chip micro-computer based controller. The system was also equipped with the devices that perform the functions of self-checking and intermittent air injection for cleaning seed tubes. The performance of the system was tested in the laboratory and field. Using the well-cleaned rice seed, the average time for checking the mis-sowing was 1.37 seconds in the field and 1.2 seconds in the laboratory without any malfunction. Overall evaluation of the system indicated that the system can be utilized for seeding machines not only for paddies but beans and corns.

  • PDF

An Analysis on the State-Dependent Nature of DS/SSMA Unslotted ALOHA

  • Park Seong-Yong;Lee Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.8 no.2
    • /
    • pp.220-227
    • /
    • 2006
  • In this paper, we present a novel approach to analyze the throughput of direct-sequence spread spectrum multiple access (DS/SSMA) unslotted ALOHA system. In the unslotted system, the departure rate of interfering transmissions is proportional to the number of current interferers that can be regarded as the system state. In order to model this state-dependency, we introduce a two-dimensional state transition model that describes the state transition of the system. This model provides a more rigorous analysis tool for the DS/SSMA unslotted ALOHA systems with both fixed and variable packet lengths. Numerical results reveal that this analysis yields an accurate system performance that coincides with the simulation results. Throughout the analysis we have discovered that the state-dependency of the departure rate causes interference averaging effect in the unslotted system and that this effect yields a higher throughput for the unslotted system than for the slotted system when supported by a strong channel coding.