The maintenance of physiological activity during dilution is very critical for the accurate enumeration of Vibrio spp. in marine samples. We investigated the effect of various diluents on the recovery of Vibrio parahaemolyticus using the direct plate counting and most probable number (MPN) methods. The effects of NaCl (0.85 and 3%) and pH (from 6.6 to 7.4) in diluents based on distilled water or phosphate buffered saline (PBS) were evaluated with three V. parahaemolyticus strains. PBS-3% NaCl (pH 6.6), as opposed to PBS, was the most effective diluent at maintaining viable cell numbers up to 2 log CFU/g during dilution for direct plate counting using on thiosulfate citrate bile salts sucrose (TCBS) selective agar, as well as minimizing the difference in cell numbers between TCBS and non-selective nutrient agar. It also increased counts of V parahaemolyticus inoculated into oysters relative to PBS (p<0.01), suggesting that PBS-3% NaCl (PH 6.6) can reduce the problem of underestimating V. parhaemolyticus counts using PBS alone.
Effects of Ac pulse at low voltage on Saccharomyces cerevisiae were studied. The treatment of yeast suspensions contained 0.2m NaCl with 500mA for 350 sec at $40^{\circ}C$ was shown about 50% of lethality, whereas in the treatment of the same suspensions with 250mA for 250 sec at the temperature ($10^{\circ}C$) corresponding to about 10% of lethality, growth was completely inhibited instead of lethality. The effect of growth inhibition was due to occurrence of auxotrophic strains under experimental conditions. Detection of auxotrophic yeasts was done tentatively with the difference of the number of viable yeast cells between direct counting by methylene blue staining and plate-count on yeast morphology agar.
Proceedings of the Korean Society of Food Hygiene and Safety Conference
/
1996.06a
/
pp.33-33
/
1996
Interests in the field of rapid methods and automation in microbiology have been growing steadily on an international scale in recent years. International meetings concerned this problem have been held in elsewhere in the world countries since the past twenty years. But, unfortunately in the field of microbial examination in food hygiene, this problem have not yet been developed so much as in the field of clinical microbiology. Today, I would like to introduce you here present aspects of rapid and automation technologies, those which are manly carrying in milk and meats industries. My illustration will be given recent improved technologies using automatic apparatus and instruments along with process of microbial count procedure. Recent direct microbiological counting system (ChemeScan \ulcorner) as real time ultrasensitive analysis created by Cheminex Ltd., France is now most evolutional instrument to provide direct microbial counts, down to one cell, within 30 minutes. The results from these evaluations how a good correlation between the ChemScan system and the standard plate count method. This system will be successful application for not only in the field of pharmacology but also food microbiology. In addition, current identification of microbes by sophisticated instruments suitable for food microbiology, one of which Biology is manual system (BIOLOG\ulcorner), provides reference-level capability at a modes price. For the manual system, the color reactions in the microplate are read by eye and manually keyed into personal computer. Species identification appears on the computer screen within seconds, along with biotype patterns, a list of closely related species, and other useful statistics. In present this is useful application for microbial ecology and epidemiological survey. RiboPrinter system newly produced by DuPont is now focusing among microbiologists in the world, and is one of the biggest microbial characterization system using a DNA-based approach. The technology analyzer is bacterial culture for its genetic fingerprint or riboprint pattern. Finally Bio-cellTracer system for automatic measurement of fungal growth and Fukitori-Maseter, a Surface Hygiene Monitoring Kit by using swabe procedure in food processing environment are briefly illustrated in this presentation.
The object of this work is to improve the maintenance of bioluminescence from stored Photobacterium phosphoreum in a view of developing continuous monitoring system for pollutants. The long-term experiments were performed to determine the effect of storage temperature and immobilization on the maintenance of bioluminescence and viability of P. phosphoreum. A naturally luminescent bacterium, P. phosphoreum was starved in 2.5% Nael solution at $20^{\circ}C$, $4^{\circ}C$, -$20^{\circ}C$ and -$70^{\circ}C$ for 30 days. In vivo luminescence was measured by luminometry, and total cell concentrations and concentrations of culturable and viable cells were determined by acridine orange staining, dilution plate counting, and direct viable counting, respectively. The bioluminescence emission from cells stored at 4De was maintained up to 10 days while those with starved cells at other temperature ranges decreased to background level within 3 days. In terms of viability of cells, concentrations of cells stored at $20^{\circ}C$ were rapidly decreased as a result of cell lysis, leading to a drop in culturable and viable counts while cells stored at $4^{\circ}C$ was shown viable but nonculturable state during starvation. With immobilized cells on strontium alginate, the bioluminescence showed higher maintenance than free cells and decreased with count number of nonculturable cells.
Objectives The aim of this study is to investigate whether hwang-ryun-haedok-tang (HDT) affect proliferations of androgen-dependent LNCaP prostate cancer cells, androgen-independent PC-3, DU-145 prostate cancer cells, MCF-7 human breast cancer cells, A549, NCI-H292 human pulmonary cancer cells and K-562 human chronic myelogenous leukemia cells. Materials and Methods Effects of HDT on proliferations of each cancer cell line were investigated. 20,000 cells/well were plated in each well of 96-well culture plate. After 24 hrs, 0.01-10% of HDT in culture medium was added to cancer cells. The number of cells was counted by using SRB assay or direct cell counting method after 72 hours from drug treatment. Effect of baicalein or berebrine on proliferation was assessed according to the same method. Results (1) HDT inhibited proliferations of LNCaP, PC-3 and DU-145 prostate cancer cells. (2) HDT inhibited proliferation of MCF-7 breast cancer cells. (3) HDT also inhibited proliferations of A549, NCI-H292 pulmonary cancer cells and K-562 chronic myelogenous leukemia cells. (4) Baicalein and berberine also showed inhibitory effects on proliferations of prostate and breast cancer cells. Conclusion : HDT inhibited proliferations of human prostate, breast, pulmonary and blood cancer cells. These results suggest us the potential use of HDT as a chemopreventive or chemotherapeutic agent. Effect of HDT on human cancer should be further investigated using in vivo experimental models that can reflect pathophysiology of human cancer through another studies.
Methods for the measurement of aquatic bacteria can be divided into two groups. The first group of these methods is based on the 'replicon' concept that live bacterial cells, when diluted and transferred to a suitable medium, produce colonies. These methods distinguish living from dead bacteria, but they massively underestimate bacterial numbers. The second group of enumeration methods uses visual counting technique using specific apparatus such as a microscope. These methods are generally direct and simple, but it is very hard to distinguish between live and dead bacteria and between small particle and bacteria. Recently developed technique in staining methods has provided a reliable method of visual determination of aquatic bacteria. This uses epifluorescence microscopy to measure the total bacterial population. In order to present the fluorescence microscopy as a new methodology for the determination of bacterial numbers in water supplies, data were obtained from chlorine and monochloramine doses added to samples. Total counts by fluorescence microscopy were compared with standard plate count method. The total number of bacteria in water supplies can be determined with fluorescence microscopy. This technique allows better resolution of small bacteria and differentiation of particle from bacteria. Chloramine was found to persist longer in natural waters and prevent bacterial regrowth.
In order to develope interspecific fusion of the genus Cellulomonas capable of assimilation cellulose, the optimun conditions for the protoplast formation was investigated to examine the susceptibility of cell wall, between different species of the same genus using scanning electron microscope. The variation in the susceptibilities of Cellulomonas sp. CS 1-1 and C. flavigena to lysozyme treatment were considerably remarkable, although they belong to the same genus. The rate of protoplast formation of CS1-1 was 99.9% being treated with lysozyme $(100{\mu}g/ml)$ for 30 minute and that of C. flavigena was about 80% being treated at the concentration of $600{\mu}g/ml$ of lysozyme for 6 hours. The susceptibility of cell wall to the lysozyme treatment on protoplast formation of the strain, CS1-1 seems not to be depend on the cultural periods of cells. On the contrary, that of C. flavigena was considerably depend on the periods. Cells of C. flavigena at mid exponential phase could be more efficiently converted to protoplast cells than those at late exponential phase be done. The rate of the protoplast formation was 95%, when cells of C. flavigena at mid exponential phase were treated with lysozyme $600{\mu}g/ml$ for 6 hours and observed by SEM. In the evalution of protoplast formation of the CS1-1 results of counting method in plate after osmotic shock treatment were similar to the results of the direct observation method by means of SEM. But in the case of C. flavigena the latter method was much more reliable than the former, because the differences between the number of spheroplasts and protoplasts were not able to figure out on conuting the number of protoplast after osmotic shock tretment.
Journal of Korean Society of Environmental Engineers
/
v.31
no.1
/
pp.51-57
/
2009
Biofouling in seawater reverse osmosis (SWRO) desalination process causes many problems such as flux decline, biodegradation of membrane, increased cleaning time, and increased energy consumption and operational cost. Therefore biofouling is considered as the most critical problem in system operation. To control biofouling in early stage, detection of the most problematic bacteria causing biofouling is required. In this study, six model bacteria were chosen; Bacillus sp., Flavobacterium sp., Mycobacterium sp., Pseudomonas aeruginosa, Pseudomonas fluorescens, and Rhodobacter sp. based on report in the literature and phylogenetic analysis of seawater intake and fouled RO membrane. The adhesion to RO membrane, the high pressure resistance, and the hydrophobicity of the six model bacteria were examined to find out their fouling potential. Rhodobacter sp. and Mycobacterium sp. were found to attach very well to RO membrane surface compared to others used in this study. The test of hydrophobicity revealed that the bacteria which have high hydrophobicity or similar contact angle with RO membrane ($63^{\circ}$ of contact angle) easily attached to RO membrane surface. P. aeruginosa which is highly hydrophilic ($23.07^{\circ}$ of contact angle) showed the least adhesion characteristic among six model bacteria. After applying a pressure of 800 psi to the sample, Rhodobacter sp. was found to show the highest reduction rate; with 59-73% of the cells removed from the membrane under pressure. P. fluorescens on the other hand analyzed as the most pressure resistant bacteria among six model bacteria. The difference between reduction rates using direct counting and plate counting indicates that the viability of each model bacteria was affected significantly from the high pressure. Most cells subjected to high pressure were unable to form colonies even thought they maintained their structural integrity.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.