• Title/Summary/Keyword: direct limit

Search Result 474, Processing Time 0.025 seconds

A study on Voltage Stability Analysis by the Lyapunov Direct Method in 2-bus Systems (Lyapunov 직접법에 의한 2모선 개통의 전압안정도 해석)

  • Moon, Young-Hyun;Lee, Tae-Shik;Kim, Baik;Lee, Eung-Hyuk;Park, Neung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.106-108
    • /
    • 1993
  • This paper gives derivations of voltage collapse conditions by using the Lyapunov function, which yields the exactly same results with the sensitivity analysis approach. On the other hand, the voltage collapse phenomenon is interpreted in the physical sense, and causes of the static voltage unstability and the dynamic voltage unstability are analyzed with the use of proposed Lyapunov function. In addition a new method is developed to calculate the power capacity limit of transmission lines with respect to voltage stability. This paper shows that it is able to analyze the voltage collapse with the Lyapunov direct method in the simple 2-bus system and proposes that the method works well by observing the variation of Lyapunov function as the load is increased in the system.

  • PDF

Study on Cooling of Hydrogen Gas for the Pre-Cooler in the Hydrogen Refueling Station (수소충전소용 프리쿨러를 위한 수소가스 냉각에 관한 연구)

  • LEE, KYUNG-HAN;KOO, KYUNG-MO;RYU, CHEOL-HWI;HWANG, GAB-JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.237-242
    • /
    • 2019
  • In the hydrogen refueling station (HRS), it is need the pre-cooling system (PCS) to limit the inside temperature ($85^{\circ}C$) of the onboard thank (700 bar) and to charge the hydrogen at short time (within 3 minutes) to fuel cell electric vehicle (FCEV). From those safety reasons, the temperature of hydrogen gas must be controled $-33^{\circ}C$ to $-40^{\circ}C$ in PCS. The cooling test of the gaseous ($N_2$, He, $H_2$) was carried out using heat exchanger (pre-cooler) by indirect cooling and direct cooling method. It was confirmed that the temperature of hydrogen gas had below $-40^{\circ}C$ at below $-75^{\circ}C$ of chiller temperature in direct cooling.

Comparative Economic Analysis of RE100 Implementation Methods in South Korea (국내 RE100 이행방안의 경제성 비교분석 연구)

  • An, Sang Hyo;Woo, JongRoul
    • Current Photovoltaic Research
    • /
    • v.10 no.2
    • /
    • pp.62-71
    • /
    • 2022
  • The Global RE100 campaign is a one of the voluntary campaign, but it has a lot of influence on domestic companies that have not yet joined the Global RE100. Accordingly, the Korean government introduced the Korean RE100 (K-RE100) system to prepare an institutional mechanism for domestic companies to respond to RE100. However, in Korea, due to the high LCOE of renewable energy and institutional limitations of the power transaction system, there is a limit for companies to implement RE100 in various ways. Therefore, in this study, the implementation cost of RE100 for green tariff, REC purchase, third-party PPA, direct(or corporate) PPA, and self-generation was compared and analyzed to derive the order of implementation with the net present value (NPV) of costs incurred over 20 years. As a result, self-construction was analyzed as the most economical method, but the implementation through the green tariff seemed to be the most realistic implementation method so far. However, considering the gradually falling LCOE, third-party PPA and direct PPA could be secured competitiveness against green tariff in 2025 and 2026. Then it could allow the companies to have various portfolios for implementation of RE100.

The Physical and Mechanical Properties of the Weathered Shale Soils in Hwasun Area (화순 지역 셰일 풍화토의 물리적.역학적 특성에 관한 연구)

  • 김종렬;박정훈;김해경;강권수
    • The Journal of Engineering Geology
    • /
    • v.14 no.2
    • /
    • pp.199-210
    • /
    • 2004
  • In this study, the physical and mechanical properties of the weathered shale soils distributed in the Hwasun area have been measured in the laboratory. The physical and mechanical properties of the weathered shale soils in the study area as follows: the specific gravity is 2.66 to 2.68, the liquid limit is 36.39 to 36.92(%), the plastic limit is 18.53 to 19.48(%), the plasticity index is 17.44 to 17.86 and soil classification is CL. The maximum dry unit weight and optimum moisture content as calculated by compaction test is 22.5 to 23% and 1.58 to $1.61t/\textrm{m}^3$, respectively. The result of direct shear testing show that cohesion in saturated and unsaturated conditions increases according to the increase of dry unit weight. Internal friction angle in an unsaturated condition increases with an increase of dry unit weight, but in a saturated condition, it increases after decreasing. When compares with engineering characteristics of tile weathered shale soils in the Daegu area (Kim et al., 1995), specific gravity is found to be similar, but the liquid and plastic limit of soil samples in this study area is slightly higher than those of soil samples in the Daegu area.

An Empirical Study of the Clinically Reportable Range in Clinical Chemistry (임상보고 가능범위의 실증적 연구)

  • Chang, Sang-Wu;Lee, Sang-Gon;Choi, Ho-Seong;Song, Eun-Young;Park, Yong-Won;Lee, In-Ae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF

On Optimizing LDA-extentions Using a Pre-Clustering (사전 클러스터링을 이용한 LDA-확장법들의 최적화)

  • Kim, Sang-Woon;Koo, Byum-Yong;Choi, Woo-Young
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.3
    • /
    • pp.98-107
    • /
    • 2007
  • For high-dimensional pattern recognition, such as face classification, the small number of training samples leads to the Small Sample Size problem when the number of pattern samples is smaller than the number of dimensionality. Recently, various LDA-extensions have been developed, including LDA, PCA+LDA, and Direct-LDA, to address the problem. This paper proposes a method of improving the classification efficiency by increasing the number of (sub)-classes through pre-clustering a training set prior to the execution of Direct-LDA. In LDA (or Direct-LDA), since the number of classes of the training set puts a limit to the dimensionality to be reduced, it is increased to the number of sub-classes that is obtained through clustering so that the classification performance of LDA-extensions can be improved. In other words, the eigen space of the training set consists of the range space and the null space, and the dimensionality of the range space increases as the number of classes increases. Therefore, when constructing the transformation matrix, through minimizing the null space, the loss of discriminatve information resulted from this space can be minimized. Experimental results for the artificial data of X-OR samples as well as the bench mark face databases of AT&T and Yale demonstrate that the classification efficiency of the proposed method could be improved.

Crack Control in Reinforced Concrete Flexural Members (철근콘크리트 휨부재의 균열 제어에 관한 연구)

  • Choi, Seung-Won;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.471-478
    • /
    • 2011
  • For a practical simplicity in designing of reinforced concrete structures, the indirect crack controlling method of limiting bar spacing is adopted in KCI structural design provisions. In addition, a direct method for evaluating crack width is also provided in the appendix of the code. But there may be some mismatched results between these two crack controlling methods. In this study, limit values of maximum bar spacing calculated from KCI provisions, KCI appendix, and Frosch's equation are examined as concrete strength, cross-section height, and concrete cover are varied, and the differences are analyzed. From the results, it becomes clear that the differences between maximum bar spacing calculated from KCI code text provisions and those from KCI code appendix provisions are too significant to be neglected. Therefore, rational crack models are suggested in order to get rid of the discrepancy between the direct and indirect control methods.

Direct Detection of (1-3)-$\beta$-Glucanase Isozymes in Isoelectrofocusing Gels Using a Dye -Labeled Substrate (염료착색 기질을 이용한 IEF gel에서(1-3)-$\beta$-glucanase 동위효소의 검출)

  • Yun, Song-Joong;Lee, Myong-Chul;Kwon, In-Sook;Kim, Tae-San;Go, Seung-Joo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.2
    • /
    • pp.121-127
    • /
    • 1994
  • A procedure for the direct detection of (1-3)-$\beta$-glucanase isozymes in electrophoresis gels was developed. The procedure employed the commercial preparation of AZCL-pachyman as a chromogenic substrate for (1-3)-$\beta$-glucanases. The procedure detected the three basic isozymes which have been known to be expressed in germinating barley kernels. A major acidic and a minor isozymes were also detected in germinating kernels. The procedure was proved to be fast, simple and sensitive enough to be used for the analysis of the expression of (1-3)-$\beta$-glucanase isozymes in plant tissues. The detection limit of the procedure for the commercial preparation of Penicillium (1-3)-$\beta$-glucanase was estimated to be as low as 50$\mu$U. The procedure could be used for the investigation of (1-3)-$\beta$-glucanases in laboratories facilitated with ordinary equipments and research personnel.

  • PDF

A Study on Net-shape Technology of Automotive Lock-up Hub using Cold Back Pressure Forming (배압 성형기술을 이용한 Lock-up Hub의 정형제조 기술에 관한 연구)

  • Kwon, Y.C.;Lee, J.H.;Lee, Y.S.;Ishikawa, T.
    • Transactions of Materials Processing
    • /
    • v.17 no.2
    • /
    • pp.124-129
    • /
    • 2008
  • Net shape forging technologies give many effects into the costs and qualities for the finished products. So, the studies to reduce the additional machining amount are very important in forging industry. Specially, there are two main topics in cold forging industry, such as, tool life and precision forging. In this study, new forging technique was proposed to eliminate the machining process for fixing up the length and improve the lead accuracy of gear. The luck-up hub is manufactured through many processes, such as upsetting, piercing and direct extrusion. The gear is formed in direct extrusion process; however, lead accuracy of the gear is over allowance limit. Therefore, the additional sizing process must be added. In this study, process design for closed-die forging of a lock-up hub used for a component of automobile transmission was made using three-dimensional finite element simulations, and the strain distributions and velocity distributions are investigated through the post processor. The rigid-plastic finite-element method for back pressure forging has been used in order to reduce development time and die cost. Using the FEM simulation, we found the optimum value of back pressure. The prototypes of lock-up hub parts were forged into the net-shape. In the experiment, lead precision of tooth are measured by the CCMM(Contact Coordinate Measuring Machine). The dimensional accuracy of forged part was improved up to the 40% when back press was applied.

Detection of Multi-class Pesticide Residues Using Surface Plasmon Resonance Based on Polyclonal Antibody

  • Yang, Gil-Mo;Kang, Suk-Won
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.547-552
    • /
    • 2008
  • The detection of carbamate (carbofuran, carbaryl, benfracarb, thiodicarb, and methomil) and organophosphate (diazinon, cadusafos, ethoprofos, parathion-methyl, and chlorpyrifos) pesticide residues with very low detection limits was carried out using surface plasmon resonance (SPR) based equipment. The capacity to develop a portable SPR biosensor for food safety was also investigated. The applied ligand for the immunoassays was polyclonal goat anti-rabbit immunoglobulin (IgG) peroxidase conjugate. Concentration tests using direct binding assays showed the possibility of quantitative analysis. For ligand fishing to find a proper antibody to respond to each pesticide, acetylcholinesterase (AChE), and glutathione-S-transferase (GST) were tested. The reproducibility and precision of SPR measurements were evaluated. With this approach, the limit of detection for pesticide residues was 1 ng/mL and analysis took less than 11 min. Thus, it was demonstrated that detecting multi-class pesticide residues using SPR and IgG antibodies provides enough sensitivity and speed for use in portable SPR biosensors.