• Title/Summary/Keyword: direct discharge

Search Result 321, Processing Time 0.031 seconds

Factors Associated with the Method of Feeding Preterm Infants after Hospital Discharge (퇴원 후 미숙아의 수유 유형과 영향요인)

  • Han, Soo-Yeon;Chae, Sun-Mi
    • Child Health Nursing Research
    • /
    • v.24 no.2
    • /
    • pp.128-137
    • /
    • 2018
  • Purpose: To investigate factors that may affect the method of feeding among preterm infants at 4 weeks after discharge. Methods: This study included 222 mother-infant dyads born before a gestational age of 37 weeks. The feeding method and general medical characteristics of the participants were assessed at 4 weeks after discharge using a structured questionnaire. Multinomial logistic regression analysis was used to examine which factors were associated with breastfeeding at home. Results: Of the 222 infants who qualified for the study, 71 (32.9%) continued to receive breastmilk at 4 weeks post-discharge. Multinomial logistic regression analysis showed that breastfeeding at 4 weeks post-discharge was associated with higher breastfeeding self-efficacy, vaginal delivery (experience), direct breastfeeding in the neonatal intensive care unit (NICU), gestational age between 30 and 34 weeks, and breastmilk consumption in the NICU. The following factors were associated with mixed feeding at 4 weeks post-discharge: being employed, having higher breastfeeding self-efficacy, and direct breastfeeding in the NICU. Conclusion: NICU nurses should provide opportunities for direct breastfeeding during hospitalization and support breastfeeding to enhance breastfeeding self-efficacy. These factors may help to ensure the continuation of breastfeeding after discharge. Moreover, factors that affect breastfeeding should be considered when providing interventions.

Detection and localization of partial discharge in high-voltage direct current cables using a high-frequency current transformer (HFCT를 활용한 고전압직류송전 케이블 부분방전 위치추정)

  • Hong, Seonmin;Son, Wooyoung;Cheon, Hyewon;Kang, Daekyoung;Park, Jonghoo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.105-108
    • /
    • 2021
  • Detection and localization of partial discharge are considered critical techniques for estimating the lifetimes of power cables. High-frequency current transformers (HFCTs) are commonly used for the detection of partial discharge in high-voltage alternating current (HVAC) power cables; however, their applicability is compromised by the limitations of the installation locations. HFCTs are typically installed in cable terminals or insulation joint boxes because HVACs induce strong time-varying magnetic fields around the cables, saturating the ferromagnetic materials in the HFCTs. Therefore, partial discharges near the installation locations can be detected. In this study, the feasibility of partial discharge detection using a HFCT was investigated for high-voltage direct current (HVDC) cables. We demonstrated that the HFCT could be installed at any location in the HVDC power cable to monitor partial discharge along the entire cable length. Furthermore, we showed that the HFCT could detect the location of partial discharge with high accuracy.

Deposition of copper oxide by reactive magnetron sputtering

  • Lee, Jun-Ho;Lee, Chi-Yeong;Lee, Jae-Gap
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.49.2-49.2
    • /
    • 2010
  • Copper oxide films have been deposited on silicon substrates by direct current magnetron sputtering of Cu in O2 / Ar gas mixtures. The target oxidation occurring as a result of either adsorption or ion-plating of reactive gases to the target has a direct effect on the discharge current and the resulting composition of the deposited films. The kinetic model which relates the target oxidation to the discharge current was proposed, showing the one-to-one relationship between discharge current characteristics and film stoichiometry of the deposited films.

  • PDF

Direct Anlysis of Impurities in Solides with Glow Discharge Mass Spectrometry

  • Ki Beom Lee;Dae Won Moon;Kwang Woo Lee
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.6
    • /
    • pp.524-529
    • /
    • 1989
  • A glow discharge mass spectrometric(GDMS) analytical method was developed for direct analysis of impurities in solids. Ions extracted from a glow discharge ion source with a sample as a cathode were analyzed by a quadrupole mass filter. Ion extractions were carried out through differentially-pumped orifices biased to positive and negative potentials. Operating parameters of the glow discharge source such as discharge current, orifice-to-cathode distance, energy analyzer setting and bias voltages have been optimized. The developed GDMS was applied to the analysis of KSS copper-base alloy standards certified by Korea Standards Research Institute(KSRI). In the analysis, the reproducibility and the detection limits were estimated to be about 2.5% RSD, and in the low ppm range, respectively.

AC PDP(Plasma Display Panel)의 방전 특성 해석

  • 황기웅;정희섭;서정현
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1997.07a
    • /
    • pp.173-176
    • /
    • 1997
  • A numerical analysis of the micro-discharge in an AC pplasma dispplay cell has been made using time-deppendent, 2-dimensional multi-fluid equations to understand the discharge pphysics of He-Xe discharge. The time deppendent distribution of the electron tempperature, densities of electrons, various ions and excited sppecies, and the effects fo the wall charge accumulated on the dielectric surface are obtained and comppared with the results of direct observation of time deppendent behavior of VUV and visible sppectra from single discharge cell observed using a gated, image intensified CCD to elucidate the discharge physics.

  • PDF

A study on the estimation of hydrologic function for ecological restoration at forested wetland (산지습지의 생태적 복원을 위한 수문학적 기능 평가에 관한 연구)

  • Jung, Yu-Gyeong;Kang, Won-Seok;Lee, Heon-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.3
    • /
    • pp.97-111
    • /
    • 2022
  • This study was conducted as restoration work to improve the discharge in forested wetlands where there is a concern of damage and observed changes in the discharge and groundwater level. The monthly changes showed that during the wet season, the amount of discharge decreased after restoration and GWL increased. It showed that during the dry season, the GWL and discharge increased. The increased discharge after restoration seems to be the difference in the number of days with no rainfall duration. The change in discharge for each unit of rainfall showed a tendency to increase the baseflow and decrease the direct discharge after restoration. The recharge ratio of GWL showed a decreasing tendency as rainfall was higher. After restoration, it showed a higher tendency under rainfall with less than 20mm. It has been confirmed that the restoration implemented by the study caused such an effect as the increased baseflow and increased GWL. It would be an effective restoration method to maintain water resources in forested wetlands. In the initial rainfall, it demonstrated a certain level of effect, but it is necessary to develop a restoration technology that can decrease the amount of water discharged after the end of rainfall or during the period of no rainfall to protect and maintain the forested wetlands. Streamflow should be identified by each type of terrain of wetlands and a proper restoration countermeasure should be devised for the site where the discharge frequently occurs.

Simulation of Field Soil Loss by Artificial Rainfall Simulator - By Varing Rainfall Intensity, Surface Condition and Slope - (인공강우기에 의한 시험포장 토양유실량 모의 - 강우강도, 지표면 및 경사조건 변화 -)

  • Shin, Minhwan;Won, Chul-hee;Choi, Yong-hun;Seo, Jiyeon;Lee, Jaewoon;Lim, KyoungJae;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.785-791
    • /
    • 2009
  • Using artificial rainfall simulator, the soil loss, which is deemed as the most cause of muddy water problem among Non-point source (NPS) pollutant, was studied by the analysis of direct runoff, groundwater discharge, and soil water storage properties concerned with rainfall intensity, slope of area, and land cover. The direct runoff showed increasing tendency in both straw covered and bared soil as slope increases from 5% to 20%. The direct runoff volume from straw covered surface were much lower than bared surface. The infiltration capacity of straw covered surface increased, because the surface sealing by fine material of soil surface didn't occur due to the straw covering. Under the same rainfall intensity and slope condition, 2.4~8.2 times of sediment yield were occurred from bared surface more than straw covered surface. The volume of infiltration increased due to straw cover and the direct runoff flow decreased with decrease of tractive force in surface. To understand the relationship of the rate of direct runoff, groundwater discharge, and soil water storage by the rainfall intensity, slope, and land cover, the statistical test was performed. It shows good relationship between most of factors, except between the rate of groundwater storage and rainfall intensity.

A Direct Detection of $CO_2$ in Sealed-off $CO_2$ Discharge Tube by Optoacoustic Effect

  • Kim Sung-Ho;Choi Joong-Gill;Cho Ung-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.23-25
    • /
    • 1994
  • A simple analytical method that allows direct monitoring of small amount of CO$_2$ in a CO$_2$ discharge tube which utilizes the optoacoustic detection technique is described. The dependence of the optoacoustic signal on the mole fraction of CO$_2$ was shown that the system responded linearly to the amount of CO$_2$ present in the miniature discharge cavity equipped with Cu electrodes. It was also found that fraction of dissociated CO$_2$ varied from 14 to 37% of the initial concentration which depended on the current and the pressure in the tube. This simple and easy detection method has proven to possess the practical advantages over the conventional systems for the study of CO$_2$ laser electrodes.

Effects of Hole Drilling Angle on Internal Flow of Gasoline Direct Injection Injector (Hole drilling angle이 가솔린 직접 분사식 인젝터의 내부 유동에 미치는 영향)

  • Kim, Huijun;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.197-203
    • /
    • 2021
  • In gasoline direct injection injectors, cavitation can be generated inside the hole because of their high injection pressure. In this paper, the effects of cavitation development in injector were investigated depending on the various hole drilling angles were investigated by a numerical method. In order to verify the internal flow model, injection rate and injection quantity of individual holes were measured. The BOSCH long tube method was used to measure the injection rate. As a result, even if the hole diameters were the same, the discharge coefficient differed by up to 10% depending on the hole angle. Moreover, if the hole drilling angle became greater than 30°, the area coefficient and the discharge coefficient decreased as the nozzle outlet was blocked due to cavitation.

Current, flow rate and pressure effects in a Gas-Jet-assisted Glow Discharge source (Gas-Jet-assisted Glow Discharge에서 전류, 가스 흐름 속도, 압력에 따른 영향 연구)

  • Lee, Gaeho;Kim, Dongsoo;Kim, Eunhee;Kang, Seongshik;Park, Minchun;Song, Haeran;Kim, Hasuck;Kim, Hyojin
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.483-492
    • /
    • 1994
  • Direct solid analysis of various kinds of metal samples has been conducted by glow discharge. In this laboratory, the gas-jet assisted glow discharge(GJGD) device has been developed and characterized. The effect of changes in applied current, cell pressure and flow rate on atomic emission signals obtained from a jet-assisted cathodic sputtering was investigate. The emission intensities of Cu, Zn, and Ar were measured. They were increased with the current. But the intensities were decreased by increasing the flow rate of argon due to the diffusion and transportation of particles into plasma. By increasing the pressure of the cell, the intensities were greatly decreased because of enhancement of redeposition onto the surface of the sample.

  • PDF