• 제목/요약/키워드: direct difference

검색결과 1,779건 처리시간 0.031초

Evaluation of standardized ileal digestibility of amino acids in fermented soybean meal for nursery pigs using direct and difference procedures

  • Ki Beom, Jang;Sung Woo, Kim
    • Animal Bioscience
    • /
    • 제36권2호
    • /
    • pp.275-283
    • /
    • 2023
  • Objective: This study was to evaluate standardized ileal digestibility (SID) of amino acids (AA) in fermented soybean meal (FSBM) for nursery pigs using both direct procedure and difference procedure when FSBM was added at 20% in diets. Methods: Forty-eight pigs at 9.2±0.9 kg body weight (BW) were individually housed and allotted to 4 treatments. Treatments included NFD (a semi-purified N free diet), FSD (a diet with 20% FSBM), CBD (corn basal diet), and CFD (corn basal diet:FSBM at 80:20). The FSD was used to measure AA digestibility in FSBM using the direct procedure, whereas CBD and CFD were used in the difference procedure. Pigs were fed for 10 days (0.09×BW0.75 kg per day) and euthanized to collect ileal digesta for TiO2 and AA. Results: Total endogenous AA loss was 12.1 g/kg of dry matter intake. The apparent ileal digestibility (AID) Thr was greater (p<0.05) and AID His (p = 0.073) and Leu (p = 0.052) tended to be greater using the direct procedure compared with the difference procedure. The SID Thr were greater (p<0.05) in FSBM for nursery pigs calculated using a direct procedure compared with a difference procedure. In addition, SID Lys in FSBM was about 83% to 88% for nursery pigs higher than SID Lys described in National Research Council (2012). Conclusion: The SID of AA in FSBM when included at practical levels using the direct procedure were similar to those from the difference procedure. Considering the SID of AA obtained using both direct and difference procedures, FSBM is an effective protein supplement providing highly digestible AA to nursery pigs. The SID of AA from this study was considerably higher than those previous reported. This study also indicates the importance of including the test feedstuffs at practical levels when evaluating digestibility.

경피 두개 직류 전류자극과 병행한 유산소운동이 노인 여성의 근지구력에 미치는 영향 (Effects of Transcranial Direct Current Stimulation with Aerobic Exercise on Lower Extremity Muscle Endurance for Elderly Women)

  • 조남정;김수현
    • 대한통합의학회지
    • /
    • 제6권2호
    • /
    • pp.117-123
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the effect of increased brain activity on the muscle endurance and the effect of brain activation through the combination of transcranial direct current stimulation and aerobic exercise on elderly woman. Methods : To investigate the effect of the muscle endurance on right leg, muscle endurance was evaluated by measuring the surface EMG of the muscles of the rectus femoris, biceps femoris, tibialis anterior, and gastrocnemius muscle. Results : There was a significant difference in the pre and post comparisons of muscle endurance on rectus femoris, biceps femoris, tibialis anterior muscle (p<.05). Difference of Combination of transcranial direct current stimulation and aerobic exercise group median frequency was smaller than control group (p<.05). There was not a significant difference in the pre and post comparisons of muscle endurance on biceps femoris, and gastrocnemius muscle. Difference of Combination of transcranial direct current stimulation and aerobic exercise group median frequency was showed a similar pattern. Conclusion : Through these results, It was found that increasing the brain activity by the transcranial direct current stimulation improves the exercise capacity on the elderly women. Combination of transcranial direct current stimulation and aerobic exercise maybe applied as an effective treatment for improving muscular endurance.

Comparison of Ultrasonic Velocities between Direct and Indirect Methods on 30 mm × 30 mm Spruce Lumber

  • OH, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권4호
    • /
    • pp.562-568
    • /
    • 2020
  • This study investigates the relationship between ultrasonic velocity and density in the direct method, the effect of distance between transducers in the indirect method, and the difference between the direct and indirect methods with transducers placed at a distance of 200 mm in nondestructive ultrasonic testing of spruce lumber. The direct method using 54 kHz ultrasonic transducers was applied to two planes, namely, radial section (LR) and tangential section (LT) of samples. The indirect method measurements were taken using the same transducers. Two velocities were measured at the top and bottom of the LT plane and at the two sides of the LR plane; the two values for each plane were averaged. The relationship between density and ultrasound velocity in the direct method demonstrated a positive correlation between the two variables. The difference between the two planes, LT and LR, was not statistically significant. Moreover, the distance between the transducers in the indirect method affected ultrasound velocity, with the ultrasonic velocity increasing as the distance between the transducers became larger. A transducer distance of 200 mm yielded a close approximation of the direct method results with a ratio of 0.87. Finally, no statistical evidence of a difference between the two planes in the indirect method was found. If the direct method, which requires access to two surfaces, is impractical, the indirect method can be applied.

4종의 direct composite resin의 파절강도 비교 (A Study on the fracture strength of 4 Kinds of Direct Composite Resins)

  • 김남중
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.87-92
    • /
    • 2019
  • Purpose: The Purpose of this study is to compare the fracture strength of 4 kinds of direct composite resins. Methods: his study performed experiments on the fracture strength of direct composite resins after polymerizing 4 kinds of direct composite resins on the MOD cavity standard specimens. Results: The fracture strength of Aelite(Bisco) was the highest at 176.26N(p<0.05). According to post-hoc study with Turkey honest significant difference by multiple comparison on fracture strength test results, there were statistically significant differences between all kinds of direct composite resin. But the statistical difference between Z350(3M) and Spectrum(DP) was not significant. Conclusion: Aelite(Bisco) scored the highest concerning the fracture strength.

Studies on Sex-linked Inheritance of Quantitative Characters in Direct and Reciprocal Crosses of Silkworm Bombyx mori L.

  • Reddy, N.Mal;Basavaraja, H.K.;Dar, A.K.;Kumar, N.Suresh;Dandin, S.B.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제7권1호
    • /
    • pp.15-20
    • /
    • 2003
  • The present investigation was carried out to study the possible cause for reciprocal difference in silkworm hybrids. By utilising the polyvoltine race Pure Mysore (PM) and newly evolved breeds (CSR2, CSR5, CSR16 and CSR17), the direct and reciprocal crosses of polyvoltine ${\times}$ bivoltine and also bivoltine hybrids were studied. The hybrids of polyvoltine ${\times}$ bivoltine (direct) are superior to their reciprocal crosses in respect of cocoon yield, cocoon weight and filament length. The reciprocal crosses of polyvoltine ${\times}$ bivoltine are superior to their direct crosses in respect of fecundity and short larval duration. No significant differences were observed in the characters like cocoon shell ratio, raw silk percentage, denier, reelability and neatness in both polyvoltine ${\times}$ bivoltine direct crosses and their reciprocals. The expression of cocoon characters as a function of sex revealed that direct crosses (polyvoltine ${\times}$ bivoltine) showed higher cocoon weight, pupal weight, shell weight and longer filament length in females than the reciprocal crosses (bivoltine ${\times}$ polyvoltine), where as these characters in males were almost the same in both direct and reciprocal crosses, indicating that the sex-linked genetic factor played a more important role. it was clear that difference in cocoon yield observed in reciprocal crosses of polyvoltine ${\times}$ bivoltine was due to the low cocoon and shell weight in females which was turn due to presence of early maturity genes (Lme) linked with sex-chromosome (X) which effect on larvae period of the silkworm. In bivoltine hybrids, i.e., both direct and their reciprocals crosses, all the characters viz., hatching percentage, larval duration, survival, cocoon weight, cocoon shell weight, cocoon shell ratio, raw silk percentage, filament length, denier, reelability and neatness did not show any significant difference (except number of eggs laid by moth) which could account for presence of same maturity genes (Lm) in both direct and reciprocal crosses. it was clear that reciprocal differences occur when the hybrids are prepared from the parental strains with different voltinism.

경두개 직류 전류자극이 뇌졸중 환자의 우울과 불안에 미치는 효과 (The Effects of Transcranial Direct Current Stimulation on Depression and Anxiety in Stroke Patients)

  • 조영석;김지훈
    • 대한통합의학회지
    • /
    • 제11권2호
    • /
    • pp.109-117
    • /
    • 2023
  • Purpose : Transcranial direct current stimulation is noninvasive method of cerebral cortical stimulation applied as an intervention to facilitate recovery in stroke patients. The purpose of this study was to examine the effects of transcranial direct current stimulation on depression and anxiety in stroke patients with the aim to finding a reliable method to reduce depression and anxiety in stroke patients. Methods : This study was conducted at A hospital located in D city from December 2022 to February 2023. Patients diagnosed with stroke were selected according to predefined study criteria and divided into two groups. 9 patients in experimental group underwent transcranial direct current stimulation and traditional occupational therapy, while 9 patients in the control group underwent sham transcranial direct current stimulation and traditional occupational therapy for 20 min per session 3 times per week for a total of 8 weeks. Beck depression inventory (BDI) and Beck anxiety inventory (BAI) were used to evaluate depression and anxiety in the patients before and after intervention. Wilcoxon signed rank test was used to compare differences before to after intervention. Mann-Whitney U test was used to compare the two groups. Differences with p<.05 were considered statistically significant. Results : First, both the experimental and control groups presented significant statistical difference before and after intervention on depression (p<.01). Comparison of two groups after intervention showed significant statistical difference in depression (p<.05). Second, the groups presented significant statistical difference before and after intervention on anxiety (p<.01). After intervention, the two groups showed significant statistical difference in anxiety (p<.05). Conclusion : Results of the present study demonstrated the effects of transcranial direct current stimulation on depression and anxiety in stroke patients, suggesting it may be a useful method of rehabilitation in this patient population; as such, further studies are warranted.

3차원 바디 스캐너를 이용한 남성 상의 원형의 피트성 평가 -직접평가와의 비교- (Fit Analysis for Men's Bodice Pattern Using 3D Scans -Compared to Traditional Fit Evaluation-)

  • 백경자
    • 한국의류학회지
    • /
    • 제33권1호
    • /
    • pp.139-148
    • /
    • 2009
  • In this study, we tried to verify the effectiveness of 3D scans of clothed participants from 20 to 24 year old men in fit analysis process. Carrying out fit analysis, we used 3D scan data and direct fit evaluation with the basic garments made as semi-fitted bodice pattern for men. The result of fit evaluation through 3D scan data showed the expert rated fitting items more positive than direct fit evaluation. Even though, generally there was a no significant difference in the response between 3D and direct fit analysis. Only there was a significant difference in the response to the specific place such as the center front line, neckline, shoulder seam, and etc. There was a no significant difference between the result of 3D scan and direct fit evaluation in the subjects' group. Also the result of assessment of 3D targeting consumers showed very positive and interested in using 3D scans for fit analysis. The ability to rotate the 3D scans for a variety of views proved to be a very effective process to analyze fit. Moreover, digital data is easily accessed at any locations and any time. Fit analysis using 3D scans could be great tool for not only fit evaluation in research but also better fitting in apparel industry.

직접혈압측정치와 3가지 간접혈압측정치의 비교 (A Comparision of a Direct and Three Indirect Methods of Measuring Blood Pressure)

  • 이명화;박효경;손수경
    • 기본간호학회지
    • /
    • 제5권1호
    • /
    • pp.95-106
    • /
    • 1998
  • The purpose of this study was to compare direct and three indirect blood pressure measurements in adults and to compare among three indirect blood pressure measurements in adults. One direct(intraarterial) and three indirect(using a mecury sphygmomanometer, a aneroid type sphygmomanometer and an automatic auscultatory device) methods of blood pressure measurement were compared in adult patients who had an arterial line. The subjects for this study consisted of 29 patients in K medical center, B medical center, B hospital and M hospital in Pusan. The data was collected from October 1, 1992 to June 30, 1993. The collected data was analysed with the SPSS program, frequency, percentage, mean, S.D., t-test, ANOVA. The results of this study were as follows : 1) There was a significant difference in the systolic BP when using the direct and three indirect measurements(P<0.05). 2) There was no overall significant difference in the diastolic BP when using the direct and three indirect measurements. 3) There was no significant difference in the SBP and DBP among the three indirect measurements.

  • PDF

간접보기 도구를 이용한 치과 진료 관련 작업자세에 대한 인간공학적 분석 (An Ergonomic Analysis on Working Posture Associated with Dental Treatment Using Indirect Viewing Method)

  • 손창원;최순영;박동현
    • 대한안전경영과학회지
    • /
    • 제12권2호
    • /
    • pp.55-64
    • /
    • 2010
  • This study tried to focus on nontraditional job that has not been studied in terms of the subjects associated with MSDs(Musculoskeletal Disorders). Specifically, dental procedure was the job to be analyzed in this study. An alternative method as well as a traditional method for viewing teeth while performing simulated dental procedures. Four graduated students did both methods(direct view and indirect view) as the subjects in this study. The method based on indirect view used a video camera and monitor to view the teeth. The experiment was conducted five times for each subject. The major findings in this study were as follows; 1) Job speed was increased with the repetitions for both methods, 2) Difference of Neck flexion between direct and indirect methods was statistically siginificant(Neck flexion for indirect method was dramatically decreased), 3) Difference of job speed between direct and indirect methods was statistically significant(Job speed for direct method was faster than that of indirect method), 4) Difference of error rate between direct and indirect methods was statistically significant(error rate for direct method was lower than that of indirect method), 5) Even though indirect method did not provide better performance in terms of job speed and error rate yet, it seemed to need a trade-off between two methods in the future since indirect method provided better working postures than that of direct method.

A fourth order finite difference method applied to elastodynamics: Finite element and boundary element formulations

  • Souza, L.A.;Carrer, J.A.M.;Martins, C.J.
    • Structural Engineering and Mechanics
    • /
    • 제17권6호
    • /
    • pp.735-749
    • /
    • 2004
  • This work presents a direct integration scheme, based on a fourth order finite difference approach, for elastodynamics. The proposed scheme was chosen as an alternative for attenuating the errors due to the use of the central difference method, mainly when the time-step length approaches the critical time-step. In addition to eliminating the spurious numerical oscillations, the fourth order finite difference scheme keeps the advantages of the central difference method: reduced computer storage and no requirement of factorisation of the effective stiffness matrix in the step-by-step solution. A study concerning the stability of the fourth order finite difference scheme is presented. The Finite Element Method and the Boundary Element Method are employed to solve elastodynamic problems. In order to verify the accuracy of the proposed scheme, two examples are presented and discussed at the end of this work.