• 제목/요약/키워드: direct comparison

검색결과 1,569건 처리시간 0.033초

다양한 시험법에 의한 토목섬유 사이의 접촉 전단 강도 평가 (Evaluation of interface shear strength between geosynthetics using three kinds of testing methods)

  • 서민우;박준범;박인준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.356-363
    • /
    • 2004
  • In this research, the shear behavior of four different interfaces consisting of 4 types of geosynthetics was examined, and both static and dynamic tests for the geosynthetic interface were conducted. The monotonic shear experiments were performed by using an inclined board apparatus and large direct shear device. The interface shear strength obtained from the inclined board tests were compared with those calculated from large direct shear tests. The comparison results indicated that direct shear tests are likely to overestimate the shear strength in low normal stress range where direct shear tests were not performed. Curved failure envelopes were also obtained for interface cases where two static shear tests were conducted. By comparing the friction angles measured from three tests, i.e. direct shear, inclined board, and shaking table tests, it was found that the friction angle might be different depending on the test method and normal stresses applied in this research. Therefore, it was concluded that the testing method should be determined carefully by considering the type of loads and the normal stress expected in the field.

  • PDF

Direct Georeferencing에 의한 CCD 영상의 적용기법 (Application of CCD Image by Direct Georeferencing)

  • 송연경;박운용;박홍기
    • 한국측량학회지
    • /
    • 제23권1호
    • /
    • pp.77-88
    • /
    • 2005
  • Direct Georeferencing을 이용한 항공사진측량 방법에서는 항공기에 탑재한 GPS와 INS로 센서의 위치와 회전각을 정확히 결정함으로써 외부표정요소 결정을 위한 지상기준점 측량을 생략하거나 또는 최소한의 기준점만을 사용하여 외부표정요소를 결정할 수 있다. 따라서 본 연구에서는 측량 시에 항측기에 GPS와 INS 및 CCD 카메라를 탑재하여 동시에 측량을 하고, Direct Georeferencing에 의한 CCD 영상으로 수치정사영상을 제작하여, 수치정사영상의 적용 가능성을 평가하고자 하였다. 본 연구에서 제작된 결과물에 대한 정확도 검증을 위하여 GPS로 측량한 지상 검사점을 기본으로 하여 Direct Georeferencing에 의하여 제작된 수치정사영상의 위치 정확도를 평가하였다. 수치정사영상은 소수의 기준점을 사용한 경우와 기준점을 사용하지 않은 경우의 두 가지로 제작하였다. Direct Georeferencing에 의한 수치정사영상의 제작 작업은 소수의 기준점을 사용하는 경우에 1:1,000 수치지도를 수정·갱신할 수 있으며, 기준점 없이 제작된 정사영상의 경우에는 축척 1:5,000 수치지도를 수정·갱신할 수 있을 것으로 판단된다.

서미스터 마운트 교정을 위한 10 MHz에서 1 GHz 주파수 대역의 단순 직접 비교 측정시스템 설계 (Design of Simple Direct Comparison Measurement System from 10 MHz to 1 GHz for Thermistor Mounts Calibration)

  • 차윤배;장용근;김부일
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.405-412
    • /
    • 2020
  • 서미스터 마운트는 전력의 변화에 따른 교정인자 값이 일정하여 정밀한 무선주파수 전력 측정에 사용하고 있다. 표준 마운트의 교정인자는 직류 대체법을 이용하여 전달표준과 직접 비교를 통해 10 MHz부터 1 GHz 대역까지 불확도 0.5 % 이하로 측정할 수 있다. 최근 직류 대체법 기반 정밀한 전력계의 산업계 보급으로 보다 간단하고, 빠른 측정이 가능함에 따라 동일한 불확도 수준의 단순 직접 비교 측정시스템을 설계하고, 부정합 오차의 분석을 통해 구성품의 최소 요구 사양을 제시하였다. 시스템 유효성 검증을 위해 시스템 불확도를 평가하였으며, 불확도 결과는 측정 주파수 대역에서 0.5 % 이내에서 잘 유지되었음을 보여준다.

직접 비교법을 이용한 W-Band 밀리미터파 전력 표준 전달 시스템 (A W-Band Millimeter-Wave Power Standard Transfer System Using the Direct Comparison Method)

  • 권재용;강태원;강진섭;이동준
    • 한국전자파학회논문지
    • /
    • 제24권1호
    • /
    • pp.47-54
    • /
    • 2013
  • 본 연구는 국내 최초로 개발된 직접 비교법을 이용한 W-band 밀리미터파 전력 표준 전달 시스템에 대한 것이다. 이 시스템은 75~110 GHz 대역에서 W-band 도파관형 전력감지기의 실효 효율과 교정 인자를 측정하기 위하여 개발되었다. 전력 표준 전달 시스템 구성의 핵심 요소인 방향성 결합기의 반사 특성 평가 기법을 소개하고 실험 결과를 보인다. 구현된 시스템을 이용하여 측정하고자 하는 전력감지기의 교정 인자 측정 결과를 보이고, 불확도 요인에 대하여 고찰한다. 측정 결과를 기준값과 비교하여 W-band 밀리미터파 전력 표준 전달 시스템에 의한 측정의 유효성을 검증한다.

자아존중감, 외모 비교, 미디어 관심이 외모의 사회문화적 태도, 신체 태도 및 삶의 만족에 미치는 영향 (Effects of Self-Esteem, Physical Appearance Comparison, and Media Concern on Sociocultural Attitude toward Appearance, Body Attitudes, and Life Satisfaction)

  • 이지영;박혜정
    • 한국의상디자인학회지
    • /
    • 제15권3호
    • /
    • pp.1-17
    • /
    • 2013
  • The purpose of this study was to identify the relationships among self-esteem, physical appearance comparison, media concern, sociocultural attitude toward appearance, body attitudes, and life satisfaction. Data were collected from a convenience sample of 232 female undergraduate students. Data were analyzed using factor analysis, correlation, and multiple regression. The result showed that there was a correlation between physical appearance comparison and media concern. Self-esteem, physical appearance comparison, and media concern had an indirect influence on body attitudes through sociocultural attitude toward appearance. Self-esteem and physical appearance comparison had a direct effect on body attitude. All variables did not have an influence on life satisfaction, except self-esteem.

  • PDF

콘크리트 직접인장강도의 세장비 효과 (Effect of Aspect Ratio in Direct Tensile Strength of Concrete)

  • 홍건호
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.246-253
    • /
    • 2003
  • 콘크리트 부재는 직접 인장력에 저항하도록 설계되지는 않는 것이 일반적이나, 부재의 균열강도 등을 산정하기 위해서는 반드시 확인하여야 하는 재료 특성 중의 하나이다. 콘크리트의 인장강도 시험방법은 주로 직접인장, 휨인장, 쪼갬인장의 3가지로 구분하고 있으나, 이 중 직접인장시험법은 시험체에 순수인장력을 가력할 수 있는 실험방법상의 문제로 거의 수행되지 못하여 온 것이 사실이다. 본 연구에서는 직접인장시험방법의 검토 및 시험체의 세장비, 크기 등이 직접인장강도에 미치는 영향에 대하여 연구하였다. 단부 보강편을 이용한 직접인장강도의 실험은 RILEM 및 U.S.Bureau of Reclamation의 규정을 사용하였으며, 총 4가지 종류의 세장비와 2가지 크기의 시험체에 대한 연구를 수행하였다. 실험의 결과는 동일변수의 쪼갬인장강도 및 휨인장강도와 비교$.$분석을 실시하였으며, 이를 신뢰성있는 선행 연구자들의 연구결과와 비교하여 그 타당성을 검증하였다.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • 제24권2호
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • 대한청각학회지
    • /
    • 제24권2호
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

염화반응법으로 제조된 TaCl5의 분리공정에 관한 비교 연구 (A Comparison Study on the Separation Process of TaCl5 from the Chlorinated Reaction Product)

  • 조정호;박소진;최영윤
    • Korean Chemical Engineering Research
    • /
    • 제44권3호
    • /
    • pp.259-264
    • /
    • 2006
  • 염화반응에 의한 $TaCl_5$의 제조에서 반응생성물 중 $NbCl_5$, $TiCl_4$, $FeCl_2$ 등이 주요 불순물로 존재하게 된다. $TaCl_5$$NbCl_5$는 증류나 수소 환원법에 의해 쉽게 분리가 되므로, 반응생성물에서 $TaCl_5/NbCl_5$ 혼합물을 99.9% 이상 순도로 분리하기 위해 2기의 연속식 증류공정을 사용하여 light한 성분과 heavy한 성분을 제거하는 공정을 구성하였다. 본고에서는 순차배열(direct sequence)과 비 순차배열(indirect sequence)으로서의 두 분리공정에 대한 비교연구를 상용성 화학공정모사기인 Aspen Plus 13.1을 이용해서 전산모사를 수행하였다. 비교결과 순차배열이 비 순차배열에 비하여 초기 장치투자비용이나 운전비용에서 좀 더 우수한 것으로 나타났다.

Comparison of LDL-Cholesterol direct measurement with the estimate using various formula

  • Kwon, Se Young;Na, Young-Ak
    • 대한임상검사과학회지
    • /
    • 제44권3호
    • /
    • pp.103-111
    • /
    • 2012
  • Low-Density Lipoprotein cholesterol (LDLC) is the most important marker for the treatment of hyperlipidemia in NCEP-ATP III(National Cholesterol Education Program-Adult Treatment Panel III) guideline. Therefore, LDL cholesterol is pathologically meaningful, accurate measurement should be a top priority. Currently, LDLC is directly measured in most cases, but, the estimate is still used in mass health examination or screening test. This study is about the comparison of LDL-Cholesterol direct measurement with the estimate using various formula (Friedewald: [LDL-F=TC-HDL-TG/5], Nakajima: [LDL-N=TC-HDL-TG/4], Hattori: [LDL-H =0.94TC-0.94HDL-0.19TG], Puavilai: [LDL-P=TC-HDL-TG/6], Carvalho: [LDL-C=3(TC-HDL)/4]) for calculating more accurate value. We analyzed total cholesterol (TC), try-glyceride (TG), high-density lipoprotein cholesterol (HDLC), and LDLC levels of 210 subjects between June and November in 2011. Until now, the Friedewald formula is the most commonly used estimate for the LDLC. When Friedewald formula was applied, the correlation coefficient (r) was 0.940, showing high correlation. But, the result of the direct method was significantly different, compared with those of the Friedewald formula in triglyceride levels ${\geq}400mg/dL$(p<0.05). There was the highest correlation when we used LDL-P formula(r=0.947) in triglyceride levels <400 mg/dl. Also there was the lowest mean difference regardless of triglyceride level. Therefore, the study showed that TG/6 is more precise means of calculation than TG/5. On the other hand, the calculation of LDL-Cholesterol was underestimated, compared with direct measurement. It is necessary to have more data and modified Friedewald formula should be used for the accurate calculation.

  • PDF