• 제목/요약/키워드: direct analysis method

검색결과 2,695건 처리시간 0.035초

철근콘크리트 복합구조물의 비선형 지진응답산정을 위한 Pushover해석 (Pushover Analysis for Nonlinear Seismic Response of Reinforced Concrete Mixed Building Structures)

  • 강병두;전대한;김재웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.631-638
    • /
    • 2006
  • This paper considers the nonlinear direct spectrum method to estimate seismic performance of mixed building structures without iterative computations, given dynamic property $T_1$ from stiffness skeleton curve and nonlinear pseudo acceleration $A_{1y}$ and/or ductility ratio $\mu$ from response spectrum. Nonlinear response history analysis has been performed and analysed with various earthquakes for evaluation of correctness and confidence of nonlinear direct spectrum method.

  • PDF

기존 비선형약산법들의 신뢰성 개선을 위한 비선형직접스펙트럼법 (The Nonlinear Direct Spectrum Method Improving Application and Reliability of Existing Approximate Nonlinear Methods)

  • 김재웅;강병두;전대한
    • 한국지진공학회논문집
    • /
    • 제10권4호
    • /
    • pp.55-66
    • /
    • 2006
  • 본 연구에서는 강성골격곡선으로부터 산정한 구조물의 초기 탄성진동주기 $T_1$와 응답스트럼으로부터 산정한 비선형 유사가속도 $A_{1y}/g$ 및 연성비 ${\mu}$를 사용하여, 반복적인 계산과정 없이 복합구조물의 내진성능을 평가하는 비선형직접스펙트럼법(NDSM)을 고려한다. 다양한 지진과 복합구조물에 대한 NDSM의 신뢰성과 실용성을 비선형시각이력해석(NRHA) 결과와 비교 검토하였다. 본 연구의 결론은 다음과 같다. (1) NDSM은 강성골격곡선으로부터 기본진동주기와 비선형 항복강도를 구하면, 비선형 응답스펙트럼으로부터 직접적으로 구조물의 비선형 최대응답을 산정할 수 있는 실용적인 방법으로 사료된다. (2) NDSM의 응답을 정산해와 비교한 결과, 대부분의 모델이 단순평균의 관점에서 전체 해석모델 중 3/4이 약 20% 이하의 오차를 나타내었고, 일반적으로 비선형시각이력해석의 응답보다 크게 산정되는 것으로 나타났다.

750kW Gearless PM 동기발전기 로터프레임 경량화 (Structural optimization for rotor frame of 750kW gearless type PMSG)

  • 홍혁수;박진일;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.286-289
    • /
    • 2008
  • Mass of generator is one of the most important characteristic value especially direct drive type wind turbine. This paper introduce how to decease mass of generator rotor frame without declining generator performance. To obtain optimal design of rotor frame, sensitivity analysis using Taguchi method and RSM(response surface method) are have been performed.

  • PDF

Analysis of a Building Structure with Added Viscoelastic Dampers

  • Lee, Dong-Guen;Hong, Sung-Il;Kim, Jin-Koo
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.27-35
    • /
    • 1998
  • Steel structures with added viscoelastic dampers are analysed to investigat their behavior under earthquake excitation. The direct integration method, which produces exact solution for the non-proportional or non-classical damping system, is used throughout the analysis. The results from modal strain energy method are also provided for comparison. Then a new analytical a, pp.oach, based on the rigid floor diaphragm assumption and matrix condensation technique, is introduced, and the results are compared with those obtained from direct integration method and modal strain energy method. The well known phenomenon, that the effectiveness of the viscoelastic dampers depends greatly on the location of the dampers, is once again confirmed in the analysis. It is also found that the modal strain energy method generaly underestimates the responses obtained from the direct integration method, especially when the dampers are placed in only a part of the building. The proposed method turns out to be very efficient with considerable saving in computation this and reasonably accurate considering the reduced degrees of freedom.

  • PDF

개선된 콤포넌트 모드법을 이용한 거대구조물의 동적해석 (Dynamic analysis for complex structures using the improved component mode method)

  • 심재수;박명균
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.37-44
    • /
    • 1993
  • There are a lot of linear dynamic analysis methods for complex structures. Each method has advantages and shortcomings. Method of dynamic analysis for complex structure is selected considering characteristics of dynamic loading, computer facility available number of degree of freedem and accuracy of results. It is a main point of view to get economical results rather then accurate ones for analysis of general complex structures, Mode superposition method and direct integration method are generally used. However, the characteristics of load is not considered in mode superpositon method, the personal computer cannot be used in direct integration methods. To over-come these shortcomings, the component mode method incorporating Ritz algorithm updated is proposed to solve economically dynamic behavior of the structures. The purpose of study is a formulation of algorithm, and computer programing suitable for dynamic analysis of the complex structure in personal computer environment.

  • PDF

직접필터법을 이용한 석영 분석시 고령석의 영향 및 보정방법 평가 (The evaluation of correction methods and effect of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method)

  • 피영규
    • 한국산업보건학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2009
  • To establish the Fourier-Transform Infra-Red spectrophotometry(FTIR) Direct-On-Filter(DOF) technique as a useful analytical method for quartz in respirable dust samples, an influence of the kaolinite should be corrected. Respirable dust, created in a dust chamber containing the standard material of quartz and kaolinite were collected using a cyclone equipped with a 25 mm, $0.8\;{\mu}m$ pore size DM filter as a collection medium. This study was designed to compare three methods of correction for kaolinite when quantifying the content of quartz, including the least square, the optimum choice and the spectral subtraction methods. The content of quartz in the respirable dust samples was overestimated by 6.2% when mixed with kaolinite(35.5% by weight). The content of quartz containing kaolinite(72.8% by weight) were overestimated by 32%. The spectral subtraction method underestimated the quartz content by 1.5%, while the other two correction methods, the optimum choice and the least square method, overestimated the quartz content by 1.9% to 6.4% and 0.04 to 1.1%, respectively. The results of this study are suggested that, when correcting for effects of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method, the least square method produce the most unbiased results be compared with those of other correction methods.

2010 미국프로골프협회 자료를 활용한 경로분석을 통한 경기력의 평균타수에 미치는 영향력 비교 (The study for effectiveness of golf skills to adjust average score using path analysis in 2010 PGA)

  • 민대기
    • Journal of the Korean Data and Information Science Society
    • /
    • 제22권1호
    • /
    • pp.65-71
    • /
    • 2011
  • 경로분석은 변수 사이의 관계를 규명하는 방법으로 회귀분석에서 파악하기 어려운 직접효과와 간접효과, 의사효과를 파악할 수 있는 장점이 있다. 본 연구에서는 골프경기에서 가장 중요한 경기력 요소를 이용하여 평균타수에 어떻게 직접, 간접적으로 영향을 미치는가를 경로분석을 통하여 연구하였으며 자료는 2010년 남자프로골프선수 상위권 186명을 이용하였다.

보 변환 기법을 이용한 3차원 부유체의 응답해석 (Response Analysis of 3-dimensional Floating Structure Using Beam Transformation)

  • 김병완;홍사영;경조현;조석규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.809-814
    • /
    • 2006
  • In this paper, the modified direct method employing beam transformation technique is proposed in order to efficiently calculate hydroelastic responses of floating structure. Since the proposed method expresses the displacements of three-dimensional structure with those of transformed beam which leads to small number of equations of motion, the method is numerically efficient compared to the conventional direct method. To verify the efficiency of the proposed method a 500 m-long floating structure under wave loads is considered in numerical example. Displacements, bending moments, torsion moments and shear forces are calculated and computing tine is examined. The results are also compared with those of the conventional direct method.

  • PDF

보 변환 기법을 이용한 3차원 부유체의 응답해석 (Response Analysis of 3-dimensional Floating Structure Using Beam Transformation)

  • 홍사영;경조현;조석규;김병완
    • 한국소음진동공학회논문집
    • /
    • 제17권1호
    • /
    • pp.17-23
    • /
    • 2007
  • In this paper, the modified direct method employing beam transformation technique is proposed in order to efficiently calculate hydroelastic responses of floating structure. Since the proposed method expresses the displacements of three-dimensional structure with those of transformed beam which leads to small number of equations of motion, the method is numerically efficient compared to the conventional direct method. To verify the efficiency of the proposed method, a 500 m-long floating structure under wave loads is considered in numerical example. Displacements, bending moments, torsion moments and shear forces are calculated and computing time is examined. The results are also compared with those of the conventional direct method.

엔진 흡배기 소음원 특성의 특정법에 대한 수치적 연구 (Numerical Investigations of the Experimental Techniques for Measuring the Acoustical Source Parameters of a Simplified Exhaust System)

  • 이정권;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.866-870
    • /
    • 2001
  • Measurement techniques for in-duct acoustic source parameters can be classified into the direct method and the load method, according to whether it utilizes an extra external source or not. It is reported that the load methods yield the negative source resistance and the purpose of this paper is to clarify that the time-varying nature of the source is the main cause of this physically implausible result. For this purpose, the direct and load methods for measuring the source characteristics of a simplified fluid machine are simulated using the time domain numerical analysis. In the numerical simulations, the method of characteristics is employed and the source characteristics are calculated from the resultant data. It is shown that the load method results in negative source resistance for some frequencies, whereas the direct method yields positive values for all frequencies considered. It is found that the result of load method is quite sensitive to the change of cylinder pressure or valve profile in contrast to the direct method.

  • PDF