• Title/Summary/Keyword: diopter curve

Search Result 4, Processing Time 0.018 seconds

The Comparative Analysis of Male and Female of Adult on the Base Crve, Power and Astigamtism of the Cornea (각막의 곡율반경, 굴절력, 난시에 대한 성인 남녀의 비교 분석)

  • Chio, Ho Seong;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.27-31
    • /
    • 2000
  • As the functional test of cornea. The clinical value of keratometric information was important for assessment the curvature of the cornea, the quality of the corneal surface, the stability of the corneal curvature, and the direction of the corneal astigmatism. This study was performed the comparative analysis of male and female of adult on the base curve, power and astigmatism of the Cornea. On the corneal base curve, the male right eye was 7.656 mm in vertical and 7.966 mm in horizontal. But, the male left cornea was 7.714 mm in vertical base curve and 8.026 mm in horizontal base curve. On the other hand, the female right eye cornea was 7.559 mm in vertical base curve and 7.695 mm in horizontal base curve. But, the female left eye cornea was 7.444 mm in vertical base curve and 7.742 mm in horizontal base curve. On the corneal diopter power, the male right eye was 44.063 diopter in vertical and 43.738 diopter in horizontal. But the male left eye was 44.046 diopter in vertical and 42.304 diopter in horizontal. On the other hand, the female right eye was 44.082 diopter in vertical and 43.77 diopter in horizontal. But, the female left eye was 44.347 diopter in vertical and 43.495 diopter in horizontal. According to the corneal astigmatism axis. The male right eye have 89.9% positive for with the - rule astigmatism, and 8.1 % positive for against - the - rule astigmatism. But, he male left eye have 91.89% positive for with - the - rule astigmatism, and 8.11 % positive for against - the - rule astigmatism. On the other hand, The female right eye have 76.92% positive for with - the - rule astigmatism, and 23.08 % positive for against - the - rule astigmatism. But, the female left have 80.76 % positive for with - the - rule astigmatism, and 17.31 % positive for against - the - rule as tigmatism. The diopter power of corneal astigmatism have 25.57% positive for behind 1 diopter, 44.89% positive for 1 diopter, 18.18% positive for 2 diopter, 5.11% positive for 3 diopter and 6.25% positive for over 4 diopter.

  • PDF

The Corneal Base Curve, Astigmatism, and Power of Women College Students (여대생들의 각막기본 곡률, 난시, 굴절력)

  • Kim, Douk-Hoon;Choi, Ho-Seong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.53-57
    • /
    • 2001
  • The corneal structure and function changes somewhat with aging. We were performed the analysis of women college students on the base curve, power, and astigmatism axis of the cornea by keratometer. All women subjects were between the ages of 19 and 20 years. On the corneal base curve. the right eye of the ages of 19 was 7.64 mm in vertical and 7.81 mm in horizontal. But, the left eye was 7.65 mm in vertical and 7.83 mm in horizontal on the other hand, the right and left eye of the ages of 20 was 7.72 mm in vertical and 7.75 mm in horizontal. On the corneal diopter power, the right eye of the ages of 19 was 44.21 diopter in vertical and 43.32 diopter in horizontal. But, the left eye was 44.23 diopter in vertical and 43.24 diopter in horizontal. On the other hand, the right eye of the ages of 20 was 43.67 diopter in vertical and 43.62 diopter in horizontal. But, the left eye was 43.73 diopter in vertical and 43.6 diopter in horizontal. According to the corneal astigmatism axis style, the right eye of the ages of 19 have 83% positive for with the rule astigmatism, and 16% positive for against the rule astigmatism. But, the left eye of the ages of 19 have 86% positive for with the rule astigmatism, and 12% positive for against the rule astigmatism. On the other hand, the right eye of the ages of 19 have 56% positive for with the rule astigmatism, and 44 % positive for against the rule astigmatism. But, the left eye of the ages of 20 have 56% positive for with the rule astigmatism, and 41% positive for against the rule astigmatism. According to the diopter power of corneal astigmatism. The right eye of the ages of 19 have 36% positive for behind 1 diopter and left eye have 31%. But, the right and left eye of the ages of 20 have 37.5%. The right and left eye of the ages of 19 have 42% positive for 1 diopter, and the right eye of the ages of 20 have 34.4% positive for 1 diopter and the left eye have 43.8%. The right eye of the ages of 19 have 12% positive for 2 diopter and left eye have 22%. But, the right eye of the ages of 20 have 15.6% positive for 2 diopter and the left eye have 12%. The right eye of the ages of 19 have 4% positive for 3 diopter and left eye have 3%. But, the left eye of the ages of 20 have 3% positive for 3 diopter and the left eye have 6%. On the other hand, the right eye of ages of 19 have 6% positive over 4 diopter, and the left eye have 2%. But, the right eye of ages of 20 have only 9% positive over 4 diopter.

  • PDF

A Study on Assessment of MTF Performance and Theoretical Analysis of Convex Trial Lenses (볼록 검안렌즈의 MTF 성능 분석 및 이론적 해석에 대한 연구)

  • Bang, Hyun Jin;Lee, Jong Ung;Son, Byung Ho;Ahn, Kyo Hoon;Choi, Eun Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.217-223
    • /
    • 2013
  • White light MTF(Modulation Transter Function)s of biconvex trial lenses from 10 to 20 diopter (D) were represented as a function of angular frequency and visual acuity, and then they were compared with AIM(Aerial Image Modulation) curves. All of the biconvex trial lenses evaluated in on-axis mode had MTF performance that could resolve Landolt's ring up to visual acuity 2.0. However, in a half field angle of five degrees, the trial lens of 10 diopters was able to resolve Landolt's ring up to visual acuity 0.9, and that of 20 diopter only up to visual acuity 0.8. This means that the trial lenses in the case of a half field angle of five degrees do not have sufficient resolution to measure visual acuity by 1.0.

A Study about How to Design the Rim of Spectacle Frame - Focused on the DESIGN Method of the Rim - (안경테의 프론트 설계 방법에 대한 연구 - 림(Rim) 설계 방법 중심으로 -)

  • Kang, Min-Soo;Kim, In-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.37-42
    • /
    • 2008
  • Purpose: The objective of the study: At present, the spectacles, with its use as a medical aids or a fashion trimming, are recognized as one of the living necessities which can't be separated from human body. One of the features of spectacles is that it must be worn on any part of human body. Such a feature has to be satisfied under the condition an user keeps feeling comfortable with the rim of spectacles worn. In order to ensure meeting this condition, a criterion has to be arranged for the design of the rim of spectacles. In order to manufacture a rim of spectacles which allows an user to secure a comfortable range of vision as well as enhancing the feeling when to be worn, a manufacturing standard has to be established based on optical science. No precise rim of spectacles could be made from the manufacturing method depending on the manufacturer's sensibility. When the rim of spectacles was manufactured according to the incorrect standards, it may cause an user such a fatal result as myopia, hyperopia or astigmatism. Methods: This study focuses on providing a detailed explanation about the design of rim, which is the most important element during designing a rim of spectacles, making use of the optical elements of spectacles, and helping the manufacturers and the people who work in the spectacles-related business understand and recognize what is correct and exact and then leading them to establish a standard in respect to the manufacture and selection of spectacles. Results, Conclusions: Considering the fact there happen many errors in relation with the names of rim stipulated in the provisions of International Standards Organization (ISO), due to wrong interpretation by some of the rim manufacturers, the right interpretation should be given about the bridge which is directly connected to rim, so that the rims of spectacles manufactured in Korea could keep a favorable position in competing with the foreign products of same kinds.

  • PDF