• 제목/요약/키워드: diode laser

검색결과 1,017건 처리시간 0.028초

Growth and characterization of molecular beam epitaxy grown GaN thin films using single source precursor with ammonia

  • Chandrasekar, P.V.;Lim, Hyun-Chul;Chang, Dong-Mi;Ahn, Se-Yong;Kim, Chang-Gyoun;Kim, Do-Jin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.174-174
    • /
    • 2010
  • Gallium Nitride(GaN) attracts great attention due to their wide band gap energy (3.4eV), high thermal stability to the solid state lighting devices like LED, Laser diode, UV photo detector, spintronic devices, solar cells, sensors etc. Recently, researchers are interested in synthesis of polycrystalline and amorphous GaN which has also attracted towards optoelectronic device applications significantly. One of the alternatives to deposit GaN at low temperature is to use Single Source Molecular Percursor (SSP) which provides preformed Ga-N bonding. Moreover, our group succeeds in hybridization of SSP synthesized GaN with Single wall carbon nanotube which could be applicable in field emitting devices, hybrid LEDs and sensors. In this work, the GaN thin films were deposited on c-axis oriented sapphire substrate by MBE (Molecular Beam Epitaxy) using novel single source precursor of dimethyl gallium azido-tert-butylamine($Me_2Ga(N_3)NH_2C(CH_3)_3$) with additional source of ammonia. The surface morphology, structural and optical properties of GaN thin films were analyzed for the deposition in the temperature range of $600^{\circ}C$ to $750^{\circ}C$. Electrical properties of deposited thin films were carried out by four point probe technique and home made Hall effect measurement. The effect of ammonia on the crystallinity, microstructure and optical properties of as-deposited thin films are discussed briefly. The crystalline quality of GaN thin film was improved with substrate temperature as indicated by XRD rocking curve measurement. Photoluminescence measurement shows broad emission around 350nm-650nm which could be related to impurities or defects.

  • PDF

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Application of 630-nm and 850-nm Light-emitting Diodes and Microcurrent to Accelerate Collagen and Elastin Deposition in Porcine Skin

  • Kwon, Tae-Rin;Moon, Dong Wook;Kim, Jungwook;Kim, Hyoung Jun;Lee, Seong Jae;Han, Yunhee;Dan, Hee Won;Chi, Sang Hoon;Seong, Hwan Mo;Kim, Hee Jung;Lim, Guei-Sam;Lee, Jungkwan
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.96-105
    • /
    • 2021
  • Background and Objectives Skin aging is reportedly associated with regulation in collagen and elastin synthesis. This study investigated the potential of combining light-emitting diode (LED) treatments using a 630-nm and 850-nm LED with simultaneous microcurrent application. Materials and Methods The dorsal skin of female pigs was treated with a home-use device. We examined the treatment effects using photography, thermocamera, microscopic pathology, and histological examination to determine the mechanism of action, efficacy, and safety of the procedure. A histological observation was performed using hematoxylin and eosin, Masson's trichrome, Victoria blue, and immunohistochemical staining. We also used the Sircol soluble collagen and elastin assay kit to measure the amounts of collagen and elastin in the porcine back skin tissue after 2 and 6 weeks. Results Evaluation by visual inspection and devices showed no skin damage or heat-induced injury at the treatment site. Histological staining revealed that accurate treatment of the targeted dermis layer effectively enhanced collagen and elastin deposition. Collagen type I, a protein defined by immunohistochemical staining, was overexpressed in the early stages of weeks 2 and 6. Combined therapy findings showed the superior capability of the 630-nm and 850-nm LED procedures to induce collagen; in contrast, elastin induction was more pronounced after microcurrent treatments. Conclusion The home-use LED device, comprising a combination of 630-nm and 850-nm LEDs and microcurrent, is safe and can be used as an adjunctive treatment for self-administered facial rejuvenation.

접촉식 다이오드레이저조사가 구강연조직에 미치는 조직학적 영향 (Histologic Effects of a Contact Diode Laser on Intraoral Soft Tissue)

  • ;신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제23권2호
    • /
    • pp.101-108
    • /
    • 1998
  • 본 연구는 두 가지 관점, 즉 다이오드레이저를 구강연조직에 접촉식으로 조사하여 조직을 절제할 경우 첫째 심부조직에서의 온도 상승 정도에 대한 분석 평가, 둘째 절제에 따른 조직의 열적 응고에 대한 조직학적 분석 평가를 위해 시도되었다. 연구를 위해 도축된 소의 혀 배면으로부터 5.0mm깊이에 T형 열전대(type T thermocouple)를 설치하고 조사조건에 따른 레이저절제 도주의 온도변화를 측정하고, 또한 해당조사부위의 조직을 대상으로 통법에 의한 H-E염색 후 조직학적 측면에서 열적 응고상을 검색하여 Nd:YAG레이저의 경우에서와 비교하였다. 즉 파장815nm의 다이오드레이저를 0-10W의 출력, 50Hz와 연속파의 주파수조건에서 접촉식으로 조사하였으며, 또한 파장1064nm의 Nd:YAG레이저를 0-10W의 출력, 50Hz와 100Hz의 주파수 조건에서 접촉식으로 조사하였다. 레이저의 접촉조사시 레이저광섬유 첨단부에서 10(10gm의 일정한 압력과 25mm/sec의 이동속도로 조직을 절제하였다. 레이저가 접촉조사된 조직부위를 통법에 의해 조직학적으로 H-E염색을 시행하였으며, 계측현미경을 이용하여 10배율 아래에서 조직절제의 폭과 깊이, 측방 및 하방 쪽으로 열적 응고의 폭을 계측하였다. 계측치에 대한 통계학적 처리결과 조직절제의 폭과 측방쪽으로 열적응고의 폭은 다이오드레이저에와 Nd:YAG레이저에서 같은 정도를 나타냈다. 조직절제의 깊이는 Nd:YAG레이저에서에 비해 다이오드레이저에서 더 깊었다. 하방쪽으로의 열적응고의 폭은 Nd:YAG레이저를 10Hz의 조건에서 조사한 경우에서 가장 넓었으며, 다이오드레이저를 50Hz와 연속파의 조건에서 조사한 경우에서 가장 좁았다. 레이저절제 도중 심부조직에서의 온도변화는 다이오드 레이저에서와 Nd:YAG레이저에서 모두 출력이 증가함에 따라 상승되었으며, 다이오드레이저에서 보다 Nd:YAG레이저에서 더 높이 상승되었다. 결론적으로 본 연구에서 시도된 조사조건 범위 이내에서는 구강연조직 절제시 다이오드레이저가 펄스형 광섬유 전달식 Nd:YAG레이저 보다 심부조직에서의 낮은 온도상승과 하방쪽으로의 좁은 열적 응고의 폭을 보이면서 우수한 조직절제효과를 나타냈다.

  • PDF

회절 광학 소자 기반 적응형 전조등 시스템 연구 (A Study on Adaptive Front-Lighting System based on Diffractive Optical Element)

  • 신성욱;박승호;유경선;노명재
    • 산업과 과학
    • /
    • 제2권4호
    • /
    • pp.28-35
    • /
    • 2023
  • 본 논문에서는 적응형 전조등 시스템 규정 중 일반도로 모드, 고속도로 모드, 젖은도로 모드를 만족하는 배광의 형성을 위한 회절 광학 소자를 설계하였으며, 이를 GDSII 스트림 형식의 파일로 도출하였다. 회절 광학 요소를 통해 형성된 배광의 유효성 및 백색광 구현 여부 확인을 위하여 각각 Field Tracing, Ray Tracing 기반의 시뮬레이션을 진행하여 변환빔 측정점에 대한 위치 요구사항 및 광도 요구사항의 만족을 확인하였다. 본 연구를 기반으로 적응형 전조등을 구현하는 경우, 광도의 대비 재현 및 단순한 구조의 적응형 전조등 시스템 구현이 가능할 것으로 예상된다.

Microtube Light-Emitting Diode Arrays with Metal Cores

  • Tchoe, Youngbin;Lee, Chul-Ho;Park, Junbeom;Baek, Hyeonjun;Chung, Kunook;Jo, Janghyun;Kim, Miyoung;Yi, Gyu-Chul
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.287.1-287.1
    • /
    • 2016
  • Three-dimensional (3-D) semiconductor nanoarchitectures, including nano- and micro- rods, pyramids, and disks, are emerging as one of the most promising elements for future optoelectronic devices. Since these 3-D semiconductor nanoarchitectures have many interesting unconventional properties, including the use of large light-emitting surface area and semipolar/nonpolar nano- or micro-facets, numerous studies reported on novel device applications of these 3-D nanoarchitectures. In particular, 3-D nanoarchitecture devices can have noticeably different current spreading characteristics compared with conventional thin film devices, due to their elaborate 3-D geometry. Utilizing this feature in a highly controlled manner, color-tunable light-emitting diodes (LEDs) were demonstrated by controlling the spatial distribution of current density over the multifaceted GaN LEDs. Meanwhile, for the fabrication of high brightness, single color emitting LEDs or laser diodes, uniform and high density of electrical current must be injected into the entire active layers of the nanoarchitecture devices. Here, we report on a new device structure to inject uniform and high density of electrical current through the 3-D semiconductor nanoarchitecture LEDs using metal core inside microtube LEDs. In this work, we report the fabrications and characteristics of metal-cored coaxial $GaN/In_xGa_{1-x}N$ microtube LEDs. For the fabrication of metal-cored microtube LEDs, $GaN/In_xGa_{1-x}N/ZnO$ coaxial microtube LED arrays grown on an n-GaN/c-Al2O3 substrate were lifted-off from the substrate by wet chemical etching of sacrificial ZnO microtubes and $SiO_2$ layer. The chemically lifted-off layer of LEDs were then stamped upside down on another supporting substrates. Subsequently, Ti/Au and indium tin oxide were deposited on the inner shells of microtubes, forming n-type electrodes of the metal-cored LEDs. The device characteristics were investigated measuring electroluminescence and current-voltage characteristic curves and analyzed by computational modeling of current spreading characteristics.

  • PDF

광섬유 산란형 센서를 이용한 사회기반시설물의 보안에 관한 연구 (A Study on the Security of Infrastructure using fiber Optic Scattering Sensors)

  • 권일범;윤동진;이승석
    • 비파괴검사학회지
    • /
    • 제24권5호
    • /
    • pp.499-507
    • /
    • 2004
  • 광섬유 ROTDR (Rayleigh optical time domain reflectometry) 센서와 보디 긴 광섬유를 감지광섬유로 사용할 수 있는 광섬유 BOTDA (Brillouin optical time domain analysis) 센서를 구성하고, 이들 각각을 이용하여 중요보안 대상체인 사회기반시설물에 침투하는 침입자를 탐지할 수 있는 기포 연구를 수행하였다 ROTDR 센서의 감지부로는 넓은 면적을 감지할 수 있는 매설형 광섬유 센서 탐지판을 제작하고, 인가된 침입물체의 위치와 무게에 따른 신호특성을 고찰하였다. ROTDR 센서는 펄스 폭이 30ns이고, 광섬유의 길이는 10km 이상이다. 위치탐지오차는 약 2m 이내였으며, 무게에 따른 탐지능력은 20kgf, 40kgf, 60kgf, 80 kgf의 네 단계를 구분할 수 있음을 알 수 있었다. 넓은 지역에 걸친 침입자의 침투를 감시하기 위하며 수십 km의 광섬유 길이 전제를 감지부로 사용할 수 있는 광섬유 BOTDA 센서를 개발하였다. BOTDA 센서는 한 개의 레이저 다이오드와 두 개의 광전 변조기(electro-optic modulator)를 사용하여 간단하게 구성하였다. 침입자에 의한 광섬유의 변형률 벽화를 탐지하는 실험을 수행하기 위하여 광학테이블 위에 광섬유에 변형률을 인가하기 위한 실험 장치를 설치하여 실험을 수행하였다. 이 실험으로부터 시간간격 1.5 초동안 광섬유 약 4.81km의 길이를 거리분해능 3m로 침입자를 탐지할 수 있음을 확인하였다.

다중 사용자 환경에서의 광 CDMA 시스템 성능 분석 (Performance Analysis of an Optical CDMA System for multi-user Environment)

  • 전상영;김영일;이주희
    • 한국통신학회논문지
    • /
    • 제24권6B호
    • /
    • pp.1134-1141
    • /
    • 1999
  • 본 논문에서는 광 코드분할 다중접속(optical code division multiple access)시스템을 구현하고 그 구현된 시스템의 성능을 분석한다. 구현된 OCDMA 시스템에서 송신단은 레이저 다이오드를 이용하여 데이터를 광 펄스로 변환하며, 4단의 지연단으로 구성한 인코더를 이용하여 펄스 열로 확산한다. 수신단에서는 인코더의 지연선 구조와 동일한 구조의 디코더에서 펄스를 지연시킨 후 결합하여 수신된 신호를 복원한다. 성능분석에 있어서는, 먼저 단일 사용자 및 다중 사용자 환경 하에서 광 CDMA 신호의 auto-correlation과 cross-correlation을 분석하고, 실험을 통해 시뮬레이션 결과를 검증하였다. 또한 광섬유 지연선의 단 수 및 코드 길이 등 시스템의 성능에 영향을 미치는 파라메타를 컴퓨터 시뮬레이션을 통해 분석하였다. 실험 결과는 인코더와 디코더의 지연선 구조가 동일한 경우 펄스 열의 중앙에서 피크값의 펄스가 발생하는 auto-correlation 특성에 의해 데이터를 복원할 수 있었고, 지연선 구조가 동일하지 않은 경우 cross-correlation 특성에 의해 데이터를 복원할 수 없었다. 성능 분석 결과는 코드 길이가 감소하거나, 지연단위의 단 수를 증 $]$쳔갭\ulcorner비트 에러 확률이 감소하지만 요구되는 레이저 광원의 펄스폭이 점차로 감소하므로 시스템 구현이 어렵게 된다. 이러한 실험 및 분석 결과를 이용하면 CDMA 기술을 광 통신 네트워크로 적용할 수 있다.

  • PDF

치아우식 예방을 위한 치아미백기의 활용 : 광역동 치료로서의 접근 (Application of Teeth Whitening LED for Prevention of Dental Caries : Antimicrobial Photodynamic Therapy Approach)

  • 박초아;박호원;이주현;서현우;이시영
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.70-77
    • /
    • 2020
  • 이 연구의 목적은 악궁 전반적으로 조사가 가능한 미백 LED를 이용하여 우식원성 Streptococcus mutans에 대한 광역동 치료의 효과를 알아보기 위한 in vitro 연구이다. S. mutans를 각각 두가지 다른 단계의 상태로 배양하였다. Planktonic 상태와 Hydroxyapatite disk와 CDC biofilm reactor를 5일간 사용하여 동적인 바이오필름 상태를 형성하였다. 20 μM 로 희석한 erythrosine을 5분간 전처리한후 가정용 미백기와 진료실 미백기를 사용하여 각 15분씩 광조사를 시행하였다. 실험 종료 후 각 실험군의 Colony Forming Unit를 측정하였으며 공초점 레이저 현미경를 이용하여 각 조건에 따른 광역동 치료 효과를 비교하였다. 실험 결과 S. mutans에 대한 aPDT효과는 control군과 비교시에 각각 플랑크토닉상태와 동적인 바이오필름 상태에서 모두 통계적으로 유의한 광역동 치료 효과가 나타났다(각각 p = 0.001, p = 0.002). 하지만 동적인 바이오필름 상태에서는 플랑크토닉 상태보다 광역동치료에 내성을 지녀 항미생물 효과가 떨어지는 양상이 관찰되었다. 진료실용 미백 LED와 가정용 미백LED는 유사한 항미생물 효과를 나타냈다. 구강악궁 전반적 조사가 가능한 미백용 LED는 우식의 원인이 되는 S. mutans 바이오필름에 유의한 광역동 치료의 효과를 나타냈으며, 이러한 결과는 치아 우식 예방으로의 광역동 치료의 임상적 적용 가능성을 제시한다.