• Title/Summary/Keyword: diode laser

Search Result 1,017, Processing Time 0.025 seconds

Analysis of Level Characteristics of 630nm Light Emitting Diode Module (630nm Light Emitting Diode 모듈의 레벨 특성 평가)

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil;Kim, Seong-Hwan;Song, Chang-Hun;Kim, Young-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.347-348
    • /
    • 2006
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. The equipment have been manufactured by using the High Bright Light Emitting Diode and TLC5941 integrated circuit. As a result, 630nm Light Emitting Diode Module was made for the optimization of irradiation condition. And we confirmed the current change according to increase of the level of Light Emitting Diode Module.

  • PDF

Diode laser surgery in the treatment of oral proliferative verrucous leukoplakia associated with HPV-16 infection

  • Bombeccari, Gian Paolo;Garagiola, Umberto;Candotto, Valentina;Pallotti, Francesco;Carinci, Francesco;Gianni, Aldo Bruno;Spadari, Francesco
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.16.1-16.5
    • /
    • 2018
  • Background: Proliferative verrucous leukoplakia (PVL) is an oral potentially malignant disorder, characterized by multifocal expression, progressive clinical evolution, and a high rate of malignant transformation. Evidence-based information regarding optimal PVL management is lacking, due to the paucity of data. The present report describes a case of PVL associated with HPV-16 infection and epithelial dysplasia treated by diode laser surgery, and the outcome of disease clinical remission over a 2-year follow-up period. Case report: A 61-year-old Caucasian male with oral verrucous hyperkeratosis presented for diagnosis. The lesions were localized on the maxillary gingiva and palatal alveolar ridge. Multiple biopsy specimens have been taken by mapping the keratotic lesion area. Microscopic examination was compatible with a diagnosis of PVL with focal mild dysplasia, localized in the right maxillary gingiva. Polymerase chain reaction (PCR) was done for human papillomavirus (HPV) detection which revealed presence of HPV DNA, and the genotype revealed HPV 16 in the sample. The PVL in the right gingival area was treated on an outpatient basis by excision with a diode laser. This approach resulted in good clinical response and decreased morbidity over a 2-year follow-up period. Conclusions: This case illustrates the benefit of a conservative approach by diode laser treatment than wide surgical excision for management of the PVL lesions associated with mild dysplasia and HPV-16 infection.

Three-dimensional micro photomachining of polymer using DPSSL (Diode Pumped Solid State Laser) with 355 nm wavelength (355nm 파장의 DPSSL을 이용한 폴리머의 3차원 미세 형상 광가공기술)

  • 장원석;신보성;김재구;황경현
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.312-320
    • /
    • 2003
  • The basic mechanistic aspects of the interaction and practical considerations related to polymer ablation were briefly reviewed. Photochemical and photothermal effects, which highly depend on laser wavelength have close correlation with each other. In this study, multi-scanning laser ablation processing of polymer with a DPSS (Diode Pumped Solid State) 3rd harmonic Nd:YVO$_4$ laser (355 nm) was developed to fabricate a three-dimensional micro shape. Polymer fabrication using DPSSL has some advantages compared with the conventional polymer ablation process using KrF and ArF laser with 248 nm and 193 nm wavelength. These advantages include pumping efficiency and low maintenance cost. And this method also makes it possible to fabricate 2D patterns or 3D shapes rapidly and cheaply because CAD/CAM software and precision stages are used without complex projection mask techniques. Photomachinability of polymer is highly influenced by laser wavelength and by the polymer's own chemical structure. So the optical characteristics of polymers for a 355 nm laser source is investigated experimentally and theoretically. The photophysical and photochemical parameters such as laser fluence, focusing position, and ambient gas were considered to reduce the plume effect which re-deposits debris on the surface of substrate. These phenomena affect the surface roughness and even induce delamination around the ablation site. Thus, the process parameters were tuned to optimize for gaining precision surface shape and quality. This maskless direct photomachining technology using DPSSL could be expected to manufacture tile prototype of micro devices and molds for the laser-LIGA process.

Review on Laser or LED Therapy for the Photobiomodulation of Diseases of the Cerebral Nervous System (뇌신경질환에 사용된 레이저 및 광선치료에 대한 임상 연구 고찰)

  • Lee, Kyung-Goo;Shin, Jong-Hun;Lee, Kyung-Jin;Sun, Seung-Ho;Han, Chang-Ho;Jang, In-Soo
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.546-555
    • /
    • 2014
  • Objectives: Recently, many studies have reported beneficial effects from the application of laser and light-emitting diode (LED) therapy for cerebral nervous disease. Transcranial laser therapy and LED therapy may be an effective method to treat diseases of the cerebral nervous system. This study aims to discuss the possibility of laser and LED therapy for cerebral nervous disease by reviewing literature about its effectiveness. Methods: We searched papers using PubMed, Science Direct, CINAHL, KTKP, Oasis and NDSL, using the keywords "Laser therapy, low-level", "Transcranial laser", "Transcranial light emitting diode" and "stroke", "traumatic brain injury", "dementia", "anxiety", "cognitive", "emotional effects", "psychiatric disorder", "multiple sclerosis", "Parkinson's disease". The search range included randomized controlled trials (RCTs) and clinical case series. Reviews and animal experiments were not included. Studies not matched with inclusion criteria were excluded. Results: A total 1,119 studies were found. 1,100 were excluded from scanning titles and abstracts and finally 9 articles were selected. Among the 9 articles, 5 were RCTs, one was a controlled study, and the other 3 were case reports. They reported that transcranial laser therapy and LED treatment had beneficial effects from photobiomodulation to the cerebral nervous system. Clinical evaluation factors showed favorable trends. Conclusions: Transcranial laser therapy and LED therapy seem to be effective to the cerebral nervous system and they may be a favorable choice for cerebral nervous disease.

Development of Laser Power Meter Calibration System with 12-diode Laser Sources (12개 다이오드 레이저를 활용하는 레이저 복사출력계 교정시스템 개발)

  • Kanghee Lee;Jae-Keun Yoo;In-Ho Bae;Seongchong Park;Dong-Hoon Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.2
    • /
    • pp.61-70
    • /
    • 2024
  • We demonstrate a laser power meter calibration system based on 12-diode laser sources coupled to single-mode fibres in a wavelength range from 400 to 1,600 nm. In our system, three laser power controllers ensure that the output power uncertainty of all laser sources is less than 0.1% (k=2). In addition, all laser beams are adjusted to have similar beam sizes of approximately 2 mm (1/e2-width) at the measurement position to minimise unmeasured laser power on a detector. As a reference detector, we use an integrating sphere combined with silicon and indium gallium arsenide photodiodes to minimise the non-uniformity and non-linearity of responsivity. The minimum uncertainty of the calibration system is estimated to be 1.1% (k=2) for most laser wavelengths.

1km Optical fiber transmission and free space characteristics of the PQR laser (PQR 레이저의 1km 광섬유 전송 및 자유공간 특성)

  • 김무성;곽규섭;김준연;김무진;권오대
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.322-325
    • /
    • 1999
  • We report fiber guiding experiments on the Photonic Quantum Ring(PQR) laser diode. In the 1km transmission measurements, we find that the PQR performs much better than the VCSEL. This suggests that the PQR laser is very promising candidate for LAN-range optical data communications. On the other hand, we have also fabricated 8$\times$8 PQR laser arrays and measured spatial decays for free space properties without using any guiding optics, which showed about 1m distance of spectral angle sensing.

  • PDF

Estimation of $CO_2$ Laser Weld Bead by Using Multiple Regression (다중회귀분석을 이용한 $CO_2$레이저 용접 비드 예측)

  • 박현성;이세헌;엄기원
    • Journal of Welding and Joining
    • /
    • v.17 no.3
    • /
    • pp.26-35
    • /
    • 1999
  • On the laser weld production line, a slight alteration of the welding condition changes the bead size and the strength of the weldment. The measurement system is produced by using three photo-diodes for detection of the plasma and spatter signal in $CO_2$ laser welding. The relationship between the sensor signals of plasma or spatter and the bead shape, and the mechanism of the plasma and spatter were analyzed for the bead size estimation. The penetration depth and the bead width were estimated using the multiple regression analysis.

  • PDF

A Study on Hardening Characteristics of High Carbon Steel by using High Power Diode Laser (고출력 다이오드 레이저를 이용한 고탄소강의 경화특성에 관한 연구)

  • Hwang, Hyun-Tae;Kim, Jong-Do;So, Sang-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.600-607
    • /
    • 2011
  • Recently, high carbon steel has become essential not only for shipbuilding parts, but also mass production. Its surface has been treated by carburizing, nitriding and induction hardening, but these existing treatments cause considerable deformation and increase the expense of postprocessing after treatment; furthermore, these treatments cannot be easily applied to parts that requiring the hardening of only a certain section. This is because the treatment cannot heat the material homogeneously, nor can it heat all of it. Laser surface treatment was developed to overcome these disadvantages, and when the laser beam is irradiated on the surface and laser speed is appropriate, the laser focal position is rapidly heated and the thermal energy of surface penetrates the material after irradiation, finally imbuing it with a new mechanical characteristic by the process of self-quenching. This research estimates the material characteristic after efficient and functional surface treatment using HPDL, which is more efficient than the existing CW Nd:YAG laser heat source. To estimate, microstructural changes and hardness characteristics of two parts (the surface treatment part, and parental material) are observed with the change of laser beam speed and surface temperature.

Endovenous 980-nm Diode Laser Treatment of Incompetent Great Saphenous Vein (정맥 내 980-nm 다이오드 레이저를 이용한 대복재정맥 역류의 치료)

  • Kim, Kun-Il;Jo, Tae-Jun;Lee, Jae-Woong;Hong, Ki-Woo;Lee, Won-Yong
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.97-102
    • /
    • 2007
  • Background: Endovenous laser treatment has recently been introduced as a less invasive technique, with many good results reported, A 980-nm diode laser was used on the great saphenous vein (GSV) occlusions in patients with varicose veins, due to GSV reflux, and the therapeutic effects analyzed. Material and Method: Between September 2003 and February 2006, 238 patients (332 cases) with GSV reflux underwent endovenous laser treatment with a 980-nm diode laser. Operative procedures were simultaneous endovenous laser treatment and ambulatory phlebectomy. The preoperative clinical findings, postoperative complications and postoperative duplex US follow up results at 1 and 3 months were reviewed. Result: Postoperative complications were ecchymosis in almost cases, paresthesia 68 cases (20.5%) and skin burn in 3 cases (0.9%). Follow up duplex US revealed 26 and 10 cases at 1 and 3 months of GSV reflux or partial recanalization, with therapeutic success rates of 91.3 and 87.9%, respectively. Conclusion: The treatment of GSV occlusion with an endovenous laser is less invasive than traditional GSV stripping, but relatively high recanalization was experienced, possibly due to inadequate laser power, laser fiber pullback speed or an extremely dilated GSV. However, continuous attempts will be required to reduce the recanalization after the procedure, with accurate follow up using duplex US.