• Title/Summary/Keyword: dilution method

Search Result 812, Processing Time 0.028 seconds

Methods for Coating the Killed Whole Cell Antigens of Salmonella typhi in Enzyme-linked Immunosorbent Assay (효소면역측정법을 위한 장티푸스 균체항원의 부착방법)

  • Kim, Youn-Won;Hwang, Eung-Soo;Kook, Yoon-Hoh;Choi, Kang-Won;Kim, Ik-Sang;Cha, Chang-Yong;Lee, Seung-Hoon
    • The Journal of the Korean Society for Microbiology
    • /
    • v.20 no.1
    • /
    • pp.91-102
    • /
    • 1985
  • The advantages of enzyme-linked immunosorbent assay(ELISA) are its senstivity and simplicity in detecting IgG, IgM and IgA antibody. To apply ELISA to diagnosis of typhoid fever, antigen such as lipopolysaccharide of Salmonella typhi or killed whole cell must be coated on solid phase. It is easy to coat lipopolysaccharide on ELISA plate but troublesome to purify it. As it is easy to obtain the killed whole cells, the development of the appropriate method by which those antigens of S. typhi are optimally coated on solid phase is needed. To establish the appropriate method, carbonate buffer, methanol or poly-L-lysine was applied as binding substance on polystyrene or polyvinylchloride plate as solid phase when the killed whole cell antigens of S. typhi varided as follows: $10^6$, $10^7$, $10^8$ and $10^9\;cell/ml$. The criteria of the optimal method were determined as follows: 1. The optical density of positive sera is above 1.0(0.6 in IgM) at 1:10 serum dilution and is 0.3(0.2 in IgM) higher than that of negative sera: 2. The O.D. of sera is flat or lowering according to serum dilution: 3. It must be that the O.D. of negative sera is lower than 0.2 at the point of serum dilution where the O.D. of positive sera is higher than 1.0(0.5 in IgM). The results obtained were summarized as follows: 1. The methods which fitted the above criteria were to use poly-L-lysine as binding substance, polyvinylchloride plate as solid phase and $10^7\;cell/ml$ as antigen concentration of S. typhi(poly-L-lysine/polyvinylchloride/$10^7$) and poly-L-lysine/polyvinylchloride/$10^8$ in detecting IgG antibody, methanol/polystyrene/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgM and carbonate buffer/polystyrene/$10^8$, carbonate buffer/polystyrene/$10^9$, methanol/polystyrene/$10^8$, methanol/polyvinylchloride/$10^8$, methanol/polyvinylchloride/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgA. 2. The coaling method using poly-L-lysine, polyvinylchloride plate and $10^8\;cell/ml$ was best to assay IgG, IgM and IgA antibody all in one. By this method, to assay the each immunoglobulin calss with an appropriate fixed serum dilution, 1:320 dilution was best.

  • PDF

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

Review on innovative small refrigeration methods for sub-Kelvin cooling

  • Dohoon, Kwon;Junhyuk, Bae;Sangkwon, Jeong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.71-77
    • /
    • 2022
  • Sub-Kelvin cooling has been generally demanded for the fields of low temperature physics, such as physical property measurements, astronomical detection, and quantum computing. The refrigeration system with a small size can be appropriately introduced when the measurement system does not require a high cooling capacity at sub-Kelvin temperature. The dilution refrigerator which is a common method to reach sub-Kelvin, however, must possess a large 3He circulation equipment at room temperature. As alternatives, a sorption refrigerator and a magnetic refrigerator can be adopted for sub-Kelvin cooling. This paper describes those coolers which have been developed by various research groups. Furthermore, a cold-cycle dilution refrigerator of which the size of the 3He circulation system is minimized, is also introduced. Subsequently, a new concept of dilution refrigerator is proposed by our group. The suggested cooler can achieve sub-Kelvin temperature with a small size since it does not require any recuperator and turbo-molecular vacuum pump. Its architecture allows the compact configuration to reach sub-Kelvin temperature by integrating the sorption pump and the magnetic refrigerators. Therefore, it may be suitably utilized in the low temperature experiments requiring low cooling capacity.

A Study for Antimicrobial Susceptibility of Wetlands to Eliminate Toilet Bacteria

  • LEE, Woo-Sik;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.3
    • /
    • pp.1-5
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate whether wetland has antimicrobial activity on pathogenic bacteria in the toilet bowl. Research design, data and methodology: Air-dried mud obtained from "Jilmoe Bog" wetland was packed and dissolved in the autoclaved saline. Antimicrobial susceptibility was assessed against three Gram-negative bacteria using disk diffusion method and broth dilution method. Identification of specific bacterium presented in wetland supernatant was performed using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Results: Incubation of three Gram-negative bacteria with wetland supernatant inhibited bacterial growth of the bacteria, otherwise increased prevalence of specific bacterium. It was confirmed that Pseudomonas putida was presented in wetland supernatant. Conclusions: The results presented in this study might provide the possibility to utilize wetland supernatant as a bioremediation of toilet bowl bacteria.

Effect of argon dilution on diamond nucleation with bias enhancement (바이어스 부가에 따른 다이아몬드 핵생성에서 아르곤 혼합의 효과)

  • 서형기;안사리S.G.;트란란안;신형식
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2002.05a
    • /
    • pp.132-132
    • /
    • 2002
  • Diamond is well known as the hardest material in nature. It also has other unique bulk physical and mechanical properties, such as very high thermal conductivity and broad optical transparency, which enable a number of new applications now that large areas of diamond can be fabricated by the new diamond plasma chemical vapor deposition (CVD) technologies. A study on the effects of growth kinetics and properties of diamond films obtained by addition of argon (~7 vol. %) into the methane/hydrogen mixture is carried out using HFCVD system. A negative bias was used as a nucleation enhancement method in addition to the argon dilution. The scanning electron microscopy (SEM) image of surface morphology shows well faceted crystallites with a predominance of angular shapes corresponding to <100> and <110> crystalline surfaces. The nucleation density and growth rate with argon dilution is two orders of magnitude higher than without argon deposition. The Raman spectra show a good quality film whereas XPS spectra show existence of only diamond phase.

  • PDF

Characteristics of NOx Emission with Flue Gas Dilution in Air and Fuel Sides

  • Cho, Eun-Seong;Chung, Suk Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2303-2309
    • /
    • 2004
  • Flue gas recirculation (FGR) is a method widely adopted to control NOx in combustion system. The recirculated flue gas decreases flame temperature and reaction rate, resulting in the decrease in thermal NO production. Recently, it has been demonstrated that the recirculated flue gas in fuel stream, that is, the fuel induced recirculation (FIR), could enhance a much improved reduction in NOx per unit mass of recirculated gas, as compared to the conventional FGR in air. In the present study, the effect of FGR/FIR methods on NOx reduction in turbulent swirl flames by using N$_2$ and CO$_2$ as diluent gases to simulate flue gases. Results show that CO$_2$ dilution is more effective in NO reduction because of large temperature drop due to the larger specific heat of CO$_2$ compared to N$_2$ and FIR is more effective to reduce NO emission than FGR when the same recirculation ratio of dilution gas is used.

Comparison of Powder Feeding and Wire Feeding in Laser Cladding (분말송급 및 와이어송급을 이용한 레이저 클래딩 특성)

  • Ahn, Young-Nam;Kim, Cheolhee
    • Journal of Welding and Joining
    • /
    • v.31 no.4
    • /
    • pp.13-16
    • /
    • 2013
  • In this research, laser cladding characteristics were investigated for various filler metal feeding methods such as powder, cold wire, and hot wire feeding. Appropriate parameter window, deposition rate, material efficiency and dilution for each filler feeding method were evaluated with same laser power and cladding speed range. Laser powder cladding has wider process parameter window but higher material efficiency and lower dilution were achieved by laser wire cladding. Among these feeding methods, laser hot-wire cladding showed best efficiency in material usage and deposition rate.

A Comparative Experiment on the Methods for Antibiotic Sensitivity Test In Vitro (항생제에 대한 세균학적 감수성시험방법에 관한 비교실험(Tetracycline, Neomycin 및 Colistin))

  • Pak, P.W.;Kim, Y.J.
    • The Journal of the Korean Society for Microbiology
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 1974
  • A comparative study was performed with 176 cultures of Salmonella organisms on tetracyline, neomycin and colistin in order to find out the relationship between the results obtained from the Ericsson's single disk method and the tube dilution method of antibiotic sensitivity tests which may be carried out in many hospital laboratories. With tetracycline, thirty-three out of 163 cultures of Salmonella typhi were found to be either sensitive or moderate sensitive by means of the disk method and thirty one(ca 94%) out of the thirty three cultures showed less than 1.0 ${\mu}g$ of the Minimal Inhibitory Concentretions(MIC) in the tube-dilution tests, which mean that there were a quite good agreement between the two methods. With neomycin, a hundred and five out of 163 S.typhi were appeared to be either sensitive or moderate sensitive by means of Ericsson's single disk method, among which 103 cultures showed less than 10.0 ${\mu}g$ MIC in the tubedilution method. And also there was a quite correlative pat. terns observed in the result of testing with 13 salmonella cultures other than S. typhi. With colistin, it was hard to observe any particular tendency in the distribution of plotting for 148 cultures showing less the 18 mm in the inhibiting zone diameters between MIC and disk sensitivity patterns except the fifteen, cultures out of 176 salmonella, which appeared to be sensitive in the single disk method and showed less than 1.0 ${\mu}g$ MIC in the tube dilution method.

  • PDF