Urgent Intracranial Carotid Artery Decompression after Penetrating Head Injury

  • Kim, Seong Joon;Park, Ik Seong
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.180-182
    • /
    • 2013
  • We describe a case of intracranial carotid artery occlusion due to penetrating craniofacial injury by high velocity foreign body that was relieved by decompressive surgery. A 46-year-old man presented with a penetrating wound to his face. A piece of an electric angular grinder disc became lodged in the anterior skull base. Computed tomography revealed that the disc had penetrated the unilateral paraclinoid and suprasellar areas without flow of the intracranial carotid artery on the lesion side. The cavernous sinus was also compromised. Removal of the anterior clinoid process reopened the carotid blood flow, and the injection of glue into the cavernous sinus restored complete hemostasis during extraction of the fragment from the face. Digital subtraction angiography revealed complete recanalization of the carotid artery without any evidence of dissection. Accurate diagnosis regarding the extent of the compromised structures and urgent decompressive surgery with adequate hemostasis minimized the severity of penetrating damage in our patient.

Giant Atherosclerotic Aneurysm of Common Femoral Artery (총대퇴동맥의 동맥경화성 거대 동맥류 -1례 보고-)

  • 장인석;김성호
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1157-1159
    • /
    • 1996
  • Atherosclerotic giant aneurysm of the common femoral artery is rare. Because the patients who lose timing of the operation face amputation or death, the surgical treatment must be performed at the proper time. A 72-old man was admitted to the hospital because of a 20-days history of pulsatile growing mass on his left groin. After the diagnosis of giant aneurysm of the common femoral artery by computerized tomography and digital subtraction angiography, an emergent operation was performed. Both deep and superficial femoral arteries were successfully reconstructed with Gore-tex grafts after aneurysmectomy. The pathology of the aneurysm was proved to be atherosclerosis.

  • PDF

A Case of Intraosseous Dural Arteriovenous Fistulas Involving Diploic Vein Treated with Transarterial Onyx Embolization

  • Shim, Jae-Hyun;Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Ra-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.260-263
    • /
    • 2011
  • Intracranial dural arteriovenous fistulas (DAVFs) are abnormal arteriovenous connections that lie within the dura. Intraosseous DAVFs involving diploic venous system are extremely rare. A 46-year-old woman presented with headache and right pulsatile tinnitus for three weeks. The tinnitus started after yelling. Digital subtraction angiography revealed DAVF within the basal portion of right parietal bone along the middle meningeal artery (MMA) groove. The fistula was fed by frontal branch of right MMA and drained into right transverse sigmoid sinus junction through dilated middle meningeal vein. The intraosseous DAVF involving diploic vein was successfully obliterated with Onyx embolization via transarterial route.

삼차원 조영증강 자기공명혈관조영술을 이용한 내경동맥 협착에 대한 평가: 디지털감산혈관조영술과의 비교

  • 한동복;최충곤;박지강;이정현;이호규
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.139-139
    • /
    • 2001
  • 목적: 경동맥 분지부에서 내경동맥 협착에 대한 평가에 있어서 삼차원 조영증강 자기공명혈관조영술의 정확도를 알아보고자 하였다. 대상 및 방법: 삼차원 조영증강 자기공명혈관조영술(3D Contrast-enhanced MRA)과 디지털감산혈관 조영술(Digital Subtraction Angiography, DSA)을 모두 시행한 35명의 환자, 68예의 내경동맥을 분석하였다. 내경동맥 협착의 측정은 North American Symptomatic Carotid Endarterectom Trial (NASCET) 기준을 이용하였다. 두 가지 검사에서 협착 정도를 경도(mild:0-29%), 중등도(moderate:30-69%), 심한 협착(severe:70-99%), 완전 폐색(occlusion:100%)등 네 그룹으로 나누었다. 두 명의 관찰자(A,B)가 DSA에서 측정한 협착 정도를 기준으로 3D Contrast-enhanced MRA에서 측정한 협착 정도를 비교하여 두 검사 방법간에 판정 일치율과 차이점을 분석하였다.

  • PDF

Endovascular Treatment Using Graft-Stent for Pseudoaneurysm of the Cavernous Internal Carotid Artery

  • Ko, Jun-Kyeung;Lee, Tae-Hong;Lee, Jae-Il;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.48-50
    • /
    • 2011
  • A 57-year-old man presented with a 2-day history of left oculomotor palsy. Digital subtraction angiography revealed a pseudoaneurysm of the left cavernous internal carotid artery (ICA) measuring $37{\times}32mm$. The pseudoaneurysm was treated with a balloon expandable graft-stent to occlude the aneurysmal neck and preserve the parent artery. A post-procedure angiogram confirmed normal patency of the ICA and complete sealing of the aneurysmal neck with no opacification of the sac. After the procedure, the oculomotor palsy improved gradually, and had completely resolved 3 months after the procedure. A graft-stent can be an effective treatment for a pseudoaneurysm of the cavernous ICA with preservation of the parent artery.

Supraceliac Aorta Bypass Surgery For Juxtarenal Aortic Occlussive Disease -2 Cases - (신장근접 대동맥 폐색증의 상복강대동맥 우회술)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.105-111
    • /
    • 1992
  • Total atherosclerotic obstruction of the juxtarenal abdominal aorta is a relatively rarely encountered form of atherosclerotic vascsular disease, accounting for less than 5% of all arterial obstrutive disease. We have encountered two patients with such lesions, both of whom were admitted for intermittent claudication of the lower extremities and symptoms of vascular ischemia. Digital subtraction angiography[DSA] was performed on both patients, the results of which revealed total obstruction of the aorta just inferior to the renal arteries without involving the latter. Operative technique involved the use of the sup-raceliac aorta as the site of proximal anastomosis of aortofemoral bypass followed by a fem-orofemoral bypass graft with Smm sized Woven Dacron[Vascutek] through a subcutaneous tunnel within the retroperitoneal space. Both patients experienced restoration of blood flow distal to the obstruction postoperatively without any complications, and OPD follow-up one month postoperatively and postoperative DSA showed evidence of continued graft patency with persistent symptomatic improvement.

  • PDF

Spontaneous Intracranial Vertebral Artery Dissection in a 2-Year-Old Child Diagnosed with High-Resolution MRI: a Case Report

  • Heo, Subin;Han, Miran;Kim, Sung Hwan;Choi, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.259-263
    • /
    • 2019
  • Although many imaging modalities can play some roles in the diagnosis of vertebral artery dissection (VAD), digital subtraction angiography (DSA) remains the gold standard method, with the highest detection rate and ability to assist in planning for endovascular treatment. However, this tool is often avoided in children because its invasive nature and it exposes them to radiation. High resolution magnetic resonance imaging (HR-MRI) have been suggested to be a reliable and non-invasive alternative, but it has never been discussed in children in whom vertebral artery dissection is a rare condition. In this report, we evaluate a case of a 2-year-old child who initially presented with cerebellar symptoms, and was early diagnosed with vertebral artery dissection using HR- MRI and was successfully treated.

Improvement of Angiogram Quality Using by High Pass Filter (고역통과필터를 이용한 혈관조영상의 화질 개선)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.301-307
    • /
    • 2014
  • In this study, an image acquired by the DSA(Digital Subtraction Angiography) system that is configured to configure the algorithm for high pass filtering algorithm experiments to improve the quality of angiography methods proposed. high pass filter is a high-frequency components pass through the filter, blocking low-frequency components. Part of the boundary line and contour of the organ corresponds to the high-frequency component is a high-frequency component of a medical image. Therefore, the high pass filter is also used for detection of the boundary line, but is also used for the high frequency enhancement. It was able to be analyzed by the proposed algorithm, to improve the quality of the angiography. Found out that the expression of the target site stand out clearly. The quality of the DSA system proposed in the wrong diagnosis software can be used to reduce, it is possible to develop and will further improve the accuracy of the treatment.

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF

The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA (4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성)

  • Bae, Sung-Jin;Lim, Cheong-Hwan;Park, Byung-Rae;Shin, Woon-Jae;Kim, Jung-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.215-221
    • /
    • 2010
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.