• Title/Summary/Keyword: digital stimulation

Search Result 108, Processing Time 0.026 seconds

Stimulus Artifact Suppression Using the Stimulation Synchronous Adaptive Impulse Correlated Filter for Surface EMG Application

  • Yeom, Ho-Jun;Park, Ho-Dong;Chang, Young-Hui;Park, Young-Chol;Lee, Kyoung-Joung
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.451-458
    • /
    • 2012
  • The voluntary EMG (vEMG) signal from electrically stimulated muscle is very useful for feedback control in functional electrical stimulation. However, the recorded EMG signal from surface electrodes has unwanted stimulation artifact and M-wave as well as vEMG. Here, we propose an event-synchronous adaptive digital filter for the suppression of stimulation artifact and M-wave in this application. The proposed method requires a simple experimental setup that does not require extra hardware connections to obtain the reference signals of adaptive digital filter. For evaluating the efficiency of this proposed method, the filter was tested and compared with a least square (LS) algorithm using previously measured data. We conclude that the cancellation of both primary and residual stimulation artifacts is enhanced with an event-synchronous adaptive digital filter and shows promise for clinical application to rehabilitate paretic limbs. Moreover because this algorithm is far simpler than the LS algorithm, it is portable and ready for real-time application.

The simulator loop probe style magnetic stimulation design for a nervous system treatment (신경계 치료를 위한 루프 프로브형 자기자극기의 시뮬레이터)

  • Kim, Whi Young
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.3
    • /
    • pp.29-37
    • /
    • 2009
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Simulator and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of loop object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment digital forming etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Neuralgia, muscular disease and Altzheimer, with stroke etc. is becoming the matter of concern and interest which disease of adult etc. it is same is important. And the melancholia in compliance with the modern direction of a ceremony which is complicated and garrulous, trillion it will cry and symptoms, it is a tendency where the emotional obstacle etc. nervous psychiatric disorder patient is increasing at class speed. But currently the applicator it will be able to treat like this disease almost it is a condition which is wholly lacking. Consequently like this disease it used magnetic stimulation and it diagnosed and the equipment it will be able to treat plan and it embodied.

The effects on the thermal changes of an acupuncture point area with the Young-Su-Bo-Sa(迎隨補瀉)-Acupuncture stimulation (영수보사(迎隨補瀉) 침자극(鍼刺戟)이 경혈영역(經穴領域)의 온도변화(溫度變化)에 미치는 영향(影響))

  • Lee, Seung-woo;Lee, Jeoung-hoon;Song, Beom-Yong;Yook, Tae-han
    • Journal of Acupuncture Research
    • /
    • v.18 no.2
    • /
    • pp.161-174
    • /
    • 2001
  • Purpose : This study is to see the existence of the meridian and the meridian point through their response to the Young-Su-Bo-Sa. Objective and Methods : For this purpose, with acupuncture stimulation with Young-Su-Bo-Sa on the Hapkok of left hand and an the non-meridian point, and using the Digital infrared thermal image(D.I.T.I), We observed and analyzed the thermal changes of Hapkok, Samgan, non-meridian point(NA), Yonghyang, Soryo, Chonchu, Shingwol. Results and Conclusions : To sum up, We could understand Young-Su-Bo-Sa stimulation through the study findings that the acupuncture stimulation on the meridian point caused significant thermal changes of the associated meridian and meridian point, and Young-Su-Bo stimulation given in the direction of the meridian passage caused increases in the thermal changes of the associated meridian point, while Young-Su-Sa stimulation caused decreases in the thermal changes of the associated meridian point.

  • PDF

The Effects of Presented Media Types on Spatial Cognition Task Performance in Preschool Children

  • Kim, Bokyung;Pack, Yun Hyun;Yi, Soon Hyung
    • Child Studies in Asia-Pacific Contexts
    • /
    • v.7 no.1
    • /
    • pp.27-38
    • /
    • 2017
  • As the use of digital media is becoming more universal and is being used in early-childhood education, understanding the effects of digital media on development is required. The purpose of this study was to examine whether child performance on a spatial cognition task depends on the type of media used to present the task and if the effect of media type is different depending on child's age and sex. To do this, a spatial cognition task set (consisting of direction, rotation, symmetry, conjugation, and part/whole tasks) was prepared, and these tasks were presented to 60 3-, 4-, and 5-year-old children using paper- and tablet-based measures. Our results showed that the correct answer rate of task performance differed significantly when completing the task on a tablet than when completing the task on paper. Generally, response times when completing the tasks on a tablet was significantly shorter than when completing the tasks on paper. Although there was no interaction between the type of media and age, and partial interaction was found between the type of media and sex. This result implies an influence of digital stimulation on child performance on the spatial cognitive task. This study provides a basic understanding for follow-up studies to examine the consequences of exposure to digital stimulation.

The Effects of Functional Electrical Stimulation on Abdominal Obesity Improvement of Adult Women by EMG, Ultrasound and DITI (근전도, 초음파와 DITI를 이용한 전기자극의 성인여성 복부비만 개선 효과 관찰)

  • Lee, Hyun-Ju;Tae, Ki-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.1051-1058
    • /
    • 2014
  • In this study, we investigated the improvement effect of obesity by treatment with a developed low frequency electrical stimulation system. Thirty female in their 20's as an experiment subjects divided 3 groups(control, commercialized device, developed device) were treated with electrical stimulation on abdomen for 4 weeks. The body weight, body mass index(BMI), waist-hip ratio(WHR), muscle strength, muscle(transverse abdominis(TrA), internal obliquus abdominis(IO), external obliquus abdominis(EO)), fat thickness and abdominal surface temperature were measured by electromyogram(EMG), ultrasound and digital infrared thermal image(DITI). In the result, the body weight and BMI were decreased. Subcutaneous abdominal fat were significantly reduced after 4 weeks. The muscle strength and TrA muscle thickness was increased 13.2%(p<0.05), and 35.5%, respectively. The fat thickness showed decrease in abdomen (p<0.05). Infrared measurement on abdominal surface temperature as a parameter of improvement in blood circulation was significantly increased(p<0.05). Therefore, the low frequency stimulation showed positive effects on parameters of the obesity improvement.

A Study on the Change in Inflammatory Activity of Macrophages and T Cells Using Pulsed Magnetic Field (펄스자기장(PMF)을 이용한 대식세포와 T 세포의 염증활성도 변화추이에 대한 연구)

  • Sojin Kim ;Hyunsook Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.324-328
    • /
    • 2023
  • Excessive inflammation in the body causes immune cells to release cytokines that damage normal tissues and cells, leading to rheumatoid arthritis and sepsis. Pulsed magnetic field(PMF) stimulation has many applications in the treatment of neurological, muscular disorders and pain. Therefore, in this study, we aim to investigate the effect of PMF stimulation on the regulation of excessive inflammation in the overall immune system. Macrophages, a primary immune cell, and T cells, a secondary immune cell, were co-cultured in the insert wells under the same conditions, and then inflammation was artificially induced. The changes in inflammatory activity following PMF stimulation were measured by pH and IL-6 concentration. After inflammation induction, both cells became more acidic and increased IL-6 expression, but after PMF stimulation, we observed improved acidification of macrophages and T cells and decreased IL-6 expression. Our results showed that infected macrophages activated T cells and that the recovery of excessive inflammatory response regulation after PMF stimulation proceeded more rapidly in macrophages. Therefore, this study suggests that PMF has a positive anti-inflammatory effect on the overall immune system and thus has the potential to be used as a non-invasive therapy for the treatment of chronic inflammatory diseases.

Design and Evaluation of Pulsed Electromagnetic Field Stimulation Parameter Variable System for Cell and Animal Models (세포 및 동물모델용 펄스형 전자기장 자극 파라미터 가변장치 설계 및 평가)

  • Lee, Jawoo;Park, Changsoon;Kim, Junyoung;Lee, Yongheum
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • An electromagnetic generator with variable stimulation parameters is required to conduct basic research on magnetic flux density and frequency for pulsed electromagnetic fields (PEMFs). In this study, we design an electromagnetic generator that can conduct basic research by providing parameters optimized for cell and animal experimental conditions through adjustable stimulation parameters. The magnetic core was selected as a solenoid capable of uniform and stable electromagnetic stimulation. The solenoid was designed in consideration of the experimental mouse and cell culture dish insertion. A voltage and current adjustable power supply for variable magnetic flux density was designed. The system was designed to be adjustable in frequency and pulse width and to enable 3-channel output. The reliability of the system and solenoid was evaluated through magnetic flux density, frequency, and pulse width measurements. The measured magnetic flux density was expressed as an image and qualitatively observed. Based on the acquired image, the stimulation area according to the magnetic flux density decrease rate was extracted. The PEMF frequency and pulse width error rates were presented as mean ± SD, and were confirmed to be 0.0928 ± 0.0934% and 0.529 ± 0.527%, respectively. The magnetic flux density decreased as the distance from the center of the solenoid increased, and decreased sharply from 60 mm or more. The length of the magnetic stimulation area according to the degree of magnetic flux density decrease was obtained through the magnetic flux density image. A PEMF generator and stimulation parameter control system suitable for cell and animal models were designed, and system reliability was evaluated.

A Study of new Algorithm for Measuring Myo-silent period (근휴지기 측정을 위한 새로운 문턱치 결정 알고리즘에 관한 연구)

  • Kim, Duck-Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1005-1006
    • /
    • 2008
  • A mechanical or electrical stimulation to the muscle always produces special phenomena, as silent period. Generally, a mechanical stimulation is followed by a single silent period, and an electrical stimulation is followed by multiple silent periods. In this paper, we propose a new algorithm for determining the duration of the silent period.

  • PDF

The Effects of Neck Extensor Vibration Stimulation on Neglect and Balance of Stroke Patients (목 폄근 진동 자극이 뇌졸중 환자의 편측무시와 균형에 미치는 효과)

  • Kim, Ji-Hoon
    • Journal of Digital Convergence
    • /
    • v.18 no.11
    • /
    • pp.303-309
    • /
    • 2020
  • This study was aimed to investigate the effects of neck extensor vibration stimulation on neglect and balance of stroke patients. Patients diagnosed with stroke were selected according to select the study target, 10 patients with experimental group with traditional occupational therapy and neck extensor vibration, and 10 patients with control group with traditional occupational therapy and neglect therapy for 30 minutes per each session 5 times a week for total 8 weeks. As a result of the study, comparison of two groups after the intervention showed that the experimental group had a more significant on the neglect and balance than the control group(p<.05). These result demonstrate that neck extensor vibration stimulation for the effective of neglect and balance in stroke patients, therefore is expected to be useful in rehabilitative therapy.

The Effects of Interferential Current Stimulation on Peripheral Blood Flow (간섭파 자극후의 말초혈류량 변화)

  • Ko, Kyung-Hyun;Kim, Ju-Cheol;Yi, Chung-Hwi
    • Journal of Korean Physical Therapy Science
    • /
    • v.1 no.1
    • /
    • pp.121-127
    • /
    • 1994
  • The purpose of this study was to determine whether vasodilation occurs when interferential current is applied to the cervical sympathetic chain and peripheral sympathetic nerves. A digital thermometer was used to record skin temperature change. The protocols used for interferential stimulation were 90-100 Hz, applied for 20 minutes via two pairs of electrodes 1) to the throat and 2) to the forearm. Forty subjects were stimulated at each of the two sites. There was no significant correlation between inital skin temperature, sex or age and temperature change. Even though there was a statistically significant temperature increase with cervical sympathetic chain stimulation, this had no clinical vasodilatory effect. More research on interferential current stimulation is needed so that the potential benefits to normal subjects and patients is better understood.

  • PDF