• Title/Summary/Keyword: digital setup

Search Result 133, Processing Time 0.021 seconds

Consideration of root position in virtual tooth setup for extraction treatment: A comparative study of simulated and actual treatment results

  • Mirinae Park;Veerasathpurush Allareddy;Phimon Atsawasuwan;Min Kyeong Lee;Kyungmin Clara Lee
    • The korean journal of orthodontics
    • /
    • v.53 no.1
    • /
    • pp.26-34
    • /
    • 2023
  • Objective: The purpose of the present study was to compare the root positions in virtual tooth setups using only crowns in a simulated treatment with those achieved in the actual treatment. Methods: Pre- and post-treatment intraoral and corresponding cone beam computed tomography (CBCT) scans were obtained from 15 patients who underwent orthodontic treatment with premolar extraction. A conventional virtual tooth setup was used for the treatment simulation. Pre- and post-treatment three-dimensional digital tooth models were fabricated by integrating the patients' intraoral and CBCT scans. The simulated root positions in the virtual setup were obtained by merging the crown in the virtual setup and root in the pre-treatment tooth model. The root positions of the simulated and actual post-treatment tooth models were compared. Results: Differences in root positions between the simulated and actual models were > 1 mm in all teeth, and statistically significant differences were observed (p < 0.05), except for the maxillary lateral incisors. The differences in the inter-root angulation were > 1° in all teeth, and statistically significant differences were observed in the maxillary and mandibular canines. Conclusions: The virtual tooth setup using only crown data showed errors over the clinical limits. The clinical application of a virtual setup using crowns and roots is necessary for accurate and precise treatment simulation, particularly in extraction treatment.

2-step Quadrature Phase-shifting Digital Holographic Optical Encryption using Orthogonal Polarization and Error Analysis

  • Gil, Sang Keun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.354-364
    • /
    • 2012
  • In this paper, a new 2-step quadrature phase-shifting digital holographic optical encryption method using orthogonal polarization is proposed and tolerance errors for this method are analyzed. Unlike the conventional technique using a PZT mirror, the proposed optical setup comprises two input and output polarizers, and one ${\lambda}$/4-plate retarder. This method makes it easier to get a phase shift of ${\pi}$/2 without using a mechanically driven PZT device for phase-shifting and it simplifies the 2-step phase-shifting Mach-Zehnder interferometer setup for optical encryption. The decryption performance and tolerance error analysis for the proposed method are presented. Computer experiments show that the proposed method is an alternate candidate for 2-step quadrature phase-shifting digital holographic optical encryption applications.

Application of CAD-CAM technology to surgery-first orthognathic approach (디지털 기술을 이용한 선수술 악교정치료)

  • Kim, Yoon-Ji;Gil, Byung-Gyu;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.622-630
    • /
    • 2018
  • For successful surgery-first approach, accurate prediction of skeletal and dental changes following orthognathic surgery is essential. With recent development of digital technology using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, attempts to provide more predictable orthodontic/orthognathic treatment have been made through 3D virtual surgery and digital tooth setup. A clinical protocol for the surgery-first orthognathic approach using virtual surgery is proposed. A case of skeletal Class III patient with facial asymmetry treated by the surgery-first approach using digital setup and virtual surgery is presented. Advantages and limitations of applying CAD/CAM technology to orthognathic surgery are discussed.

  • PDF

Digital fabrication and application of clear aligner after alignment with NiTi archwires (NiTi 호선을 이용한 초기 배열 후 디지털 방식 투명교정장치의 적용)

  • Lim, Sung-Hoon
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.551-562
    • /
    • 2016
  • There are interferences between the teeth to be moved and the clear aligner made from setup. These interferences generate forces which move teeth to the desired position. However, these can cause incomplete tooth capture of clear aligner. When these interferences exceed the acceptable deformation of aligner, unwanted intrusion of teeth to be moved occurs. When correction of rotation or tipping of teeth is attempted, intrusion prevails before rotation or tipping. However, clear aligner can induce labiolingual tipping or intrusion easily. To achieve preliminary alignment including control of rotation and tipping, NiTi archwires with fixed appliance can be used first, and then clear aligner can be used for finishing in mild Class I maloccusion cases. For this purpose, clear aligner can be made using a digital setup and 3D printing. To move teeth using a clear aligner, tooth capture is critical. To improve tooth capture of clear aligners, slingshot or vertical elastics can be used. These were discussed with illustrations.

  • PDF

Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images (방사선치료 시 환자자세 검증을 위한 분석용 도구 개발)

  • Lee Suk;Seong Jinsil;Kwon Soo I1;Chu Sung Sil;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.100-106
    • /
    • 2003
  • Purpose : To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproduclbility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT). The utilization of this system is evaluated through phantom and patient case studies. Materials and methods : We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, porial and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT Images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. Results : The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT. The results show that the localization errors are 0.8$\pm$0.2 mm (AP) and 1.0$\pm$0.3 mm (Lateral) in the cases relating to the brain and 1.1$\pm$0.5 mm (AP) and 1.0$\pm$0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software Conclusions : A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproduclbility of the patients' setup in 3DCRT and IMRT. With adjustment of the completed GUI-based algorithm, and a good quality DRR image, our software may be used for clinical applications.

Secure Recovery Protocol of (1,3) Distributed Key Share with Trustless Setup for Asset Management in Blockchain (블록체인 기반 가상자산 관리를 위한 (1,3) 분산키의 비신뢰 기반 안전한 분산 복구 프로토콜)

  • Bae, Kyoungil;Park, Junhoo;Ryou, Jaecheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.5
    • /
    • pp.863-874
    • /
    • 2021
  • Distributed key generation (DKG) with trustless setup is a cryptographic protocol that distributes Shamir secret shares of a private key to participants while keeping the actual private key hidden to the participants. Also, by extending it to a threshold signature protocol, digital signatures can be generated without construction of private keys. This paper proposes a recovery protocol maintaining trustless setup assumptions, in particular to the useful (1,3) share structure. The proposed protocol meets same levels of security requirements with DKG in terms of correctness and secrecy. The protocol can also enable delegation and revocation of digital sign rights for blockchain-based asset management.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Digital Orthodontics using Customized Appliance System (개인 맞춤형 장치를 이용한 디지털 교정치료)

  • Kim, Yoon-Ji R.;Ha, Hye-Jung;Lee, Sung-Jong;Lee, Eon-Hwa;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.134-141
    • /
    • 2016
  • Use of ready-made orthodontic appliance can lead to inefficiencies in the final stages of the orthodontic treatment. Because patients' teeth have anatomic variations, brackets that have been designed to fit on average tooth surface may result in positional discrepancies when leveling and alignment is completed. As a result, additional steps such as rebonding, wire bending and use of auxiliaries may be needed. Even in patients who have normal tooth anatomy and proper tooth size relationships, precise bracket placement is crucial in order to efficiently control the tooth positions. Digital models can provide advantages in clinical orthodontics as virtual tooth setup could be performed, and clinicians can easily visualize the predicted final occlusion. Through this setup model, customized brackets with individualized prescription and archwires that optimally fit with the patients' dental arches can be produced using CAD/CAM technology. Also, the brackets can be accurately placed with an aid of 3D-printed jigs. The purpose of this article is to introduce the commonly used labial and lingual customized orthodontic appliance systems using digital technology.

  • PDF

Off-axis self-reference digital holography in the visible and far-infrared region

  • Bianco, Vittorio;Paturzo, Melania;Finizio, Andrea;Ferraro, Pietro
    • ETRI Journal
    • /
    • v.41 no.1
    • /
    • pp.84-92
    • /
    • 2019
  • Recent advances in digital holography in the far-infrared region of the spectrum have demonstrated the potential use of digital holography in homeland security as a tool to observe hostile environments in which smoke, flames, and dust impair vision. However, to make this application practical, it is necessary to simplify the optical setup. Here, we show an off-axis, self-reference scheme that spills the reference beam out from the object beam itself and avoids the need for a complex interferometric arrangement. We demonstrate that this scheme allows the reconstruction of high-quality holograms of objects captured under visible as well as far-infrared light exposure. This could pave the way to the industrialization of holographic systems to enable users to see through fire. Moreover, the quantitative nature of the holographic signal is preserved. Thus, the reported results demonstrate the possibility to use this setup for optical metrology.

GMPLS Technology for Next Generation Multimedia Internet Services (차세대 멀티미디어 인터넷 서비스를 위한 GMPLS기술)

  • Jang Hee-Seon;Shin Hyun-Cheul
    • Journal of Digital Contents Society
    • /
    • v.3 no.2
    • /
    • pp.143-152
    • /
    • 2002
  • In this paper, we present the general interface, label-switched path structure and link bundling in GMPLS to improve the scalability. The LMP protocol is also introduced to efficiently manage the internal link, and the signaling protocol, hierarchical path setup, hi-directional LSP setup and suggested label method are presented. Finally, the techniques of protection and restoration are presented. In specific, various applicable restoration techniques in GMPLS are discussed.

  • PDF