• Title/Summary/Keyword: digital relay

Search Result 272, Processing Time 0.035 seconds

A Busbar Current Differential Relay with a Compensating Algorithm (보상 알고리즘을 적용한 모선보호용 전류차동 계전기)

  • 강용철;윤재성
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.214-220
    • /
    • 2004
  • This paper describes a busbar current differential relay in conjunction with a current transformer(CT) compensating algorithm irrespective of the level of the remanent flux. The compensating algorithm detects the start of first saturation if the third-difference function of the current exceeds the threshold; it estimates the core flux at the first saturation start by inserting the negative value of the third-difference function of the current into the magnetization curve; thereafter, it calculates the core flux during the fault and compensates the distorted current using the magnetization curve. The algorithm estimates the correct secondary current irrespective of the level of the remanent flux and needs no saturation point of the magnetization curve. The proposed relay can improve not only security of the relay on an external fault with CT saturation but sensitivity of the relay on an internal fault; the relay can improve the operating speed on n internal fault with CT saturation. This paper concludes by implementing the relay into a digital signal processor based prototype relay.

A Busbar Current Differential Relay with a Compensating Algorithm (보상 알고리즘을 적용한 모선보호용 전류차동 계전기)

  • 강용철;윤재성
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.214-214
    • /
    • 2004
  • This paper describes a busbar current differential relay in conjunction with a current transformer(CT) compensating algorithm irrespective of the level of the remanent flux. The compensating algorithm detects the start of first saturation if the third-difference function of the current exceeds the threshold; it estimates the core flux at the first saturation start by inserting the negative value of the third-difference function of the current into the magnetization curve; thereafter, it calculates the core flux during the fault and compensates the distorted current using the magnetization curve. The algorithm estimates the correct secondary current irrespective of the level of the remanent flux and needs no saturation point of the magnetization curve. The proposed relay can improve not only security of the relay on an external fault with CT saturation but sensitivity of the relay on an internal fault; the relay can improve the operating speed on n internal fault with CT saturation. This paper concludes by implementing the relay into a digital signal processor based prototype relay.

A Study on The Development and Function Test of Digital Transformer Protection Relay Using The Induced Voltage (유기전압비를 이용한 디지털형 변압기 보호계전기 개발 및 성능시험에 관한 연구)

  • Jung, Sung-Kyo;Lee, Jae-Kyung;Kim, Han-Do;Choi, Dae-Gil;Kang, Yong-Chul;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.216-218
    • /
    • 2001
  • The transformer role is very important in power system operation and control; also its price is very expensive. Therefore many kinds of the efforts for transformer protection have been executed. So for as, current differential relay(87) has been mainly used for transformer protection. But current differential relaying method has several troubles as followings. Differential current can be occurred by transformers inrush current between winding1 and winding2 of transformer when transformer is initially energized. Also harmonic restrained element used in current differential relaying method is one of the causes of relays mal-operation because recently harmonics in power system gradually increase by power switching devices(SVC, FACTS, DSC, etc). Therefore many kinds of effort have been executed to solve the trouble of current differential relay and one of them is method using ratio of increment of flux linkages(RIFL) of the primary and secondary windings. This paper introduces a novel protective relay for power transformers using RIFL of the primary and secondary windings. Novel protective relay successfully discriminates between transformer internal faults and normal operation conditions including inrush and this paper includes real time test results using RTDS(Real Time Digital Simulator) for novel protective relay. A novel protective relay was designed using the TMS320C32 digital signal processor and consisted of DSP module. A/D converter module, DI/DO module, MMI interface module and LCD display module and developed by Xelpower co., Ltd.

  • PDF

Design of the Power System Frequency Measurement Module for the Relay using the Digital Phase Locked-Loop (디지털 위상 고정 루프를 이용한 계전기용 정밀 주파수 측정 장치)

  • 윤영석;최일흥;이상윤;황동환;이상정;박장수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.365-374
    • /
    • 2004
  • The relay measures the frequency of the power system in order to detect faults and separate them from the system. Many estimation algorithms for the relay have been proposed to accurately measure the frequency. This paper proposes a new frequency measurement method using the digital phase locked-loop(DPLL) for the relay of the power system. The proposed method is configured with a DPLL scheme and verified through computer simulations and experimental tests. In order to cope with noises in the power system, filters are included in the input signal processing part and the frequency comparator. MATLAB is used for computer simulations and an experimental setup with a CPU and an FPGA(Field Programmable Gate Array) is constructed. The loop filter of the DPLL is run in the CPU software In adjust parameters and others are in the FPGA. Experimental tests are performed lot a function generator and the power system. Results show that the proposed method is appropriate to the frequency measurement for the relay.

A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data (ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

Design and Fabrication of a Digital Protection Relay for Reverse-Open Phase (디지털 역결상 보호 계전기의 설계 및 제작)

  • Kim, Woo-Hyun;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.313-319
    • /
    • 2019
  • Induction motors connected with a three-phase AC system may malfunction due to reverse phase or open phase faults. Conventional overcurrent relays and overheating relays are used to prevent such accidents; however, their drawbacks include a low response speed and false operation. Therefore, in this study, a digital relay for the reverse-open phase was designed and fabricated. This relay can detect the reverse phase and open phase faults and send a trigger signal to the control circuit. The proposed relay was developed based on a microcontroller. The detection times of the reverse phase and open phase were verified as 320ms and 80ms, respectively. Compared with conventional relays that only protect the motor from one type of fault, the proposed relay can detect both, reverse phase and open phase faults. In addition, the fault detection, identification criterion, and trigger signal patterns can be modified by programming according to the requirements of users.

Uniform Sensor-node Request Scheme for the Recovery of Sensing Holes on IoT Network (IoT 네트워크의 센싱홀 복구를 위한 센서 이동 균등 요청 방법)

  • Kim, Moonseong;Park, Sooyeon;Lee, Woochan
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.4
    • /
    • pp.9-17
    • /
    • 2020
  • When IoT sensor nodes are deployed in areas where data collection is challenging, sensors must be relocated if sensing holes occur due to improper placement of sensors or energy depletion, and data collection is impossible. The sensing hole's cluster header transmits a request message for sensor relocation to an adjacent cluster header through a specific relay node. However, since a specific relay node is frequently used, a member sensor located in a specific cluster area adjacent to the sensing hole can continuously receive the movement message. In this paper, we propose a method that avoids the situation in which the sensing hole cluster header monopolizes a specific relay node and allows the cluster header to use multiple relay nodes fairly. Unlike the existing method in which the relay node immediately responds to the request of the header, the method proposed in this paper solves a ping-pong problem and a problem that the request message is concentrated on a specific relay node by applying a method of responding to the request of the header using a timer. OMNeT++ simulator was used to analyze the performance of the proposed method.

Protective Relay Modeling of Generator Using Real Time Digital Simulator (RTDS를 이용한 발전기 보호계전기 모델링)

  • Cho, Y.S.;Lee, W.H.;Shin, J.H.;Kim, T.K.;Jang, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.155-157
    • /
    • 2005
  • Digital relays have numerous advantages over traditional analog relays, such as the ability to accomplish what is difficult or impossible using analog relays. This paper presents the protective relay modeling of generator using Real Time Digital Simulator(RTDS). The developed model is applied to the test system and the simulation results are evident that they performs satisfactory.

  • PDF

Digital Adaptive Distance Relay for Transmission Line Protection (송전선로 보호용 디지털 지능형 거리계전기)

  • Jeong, Chang-Ho;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.411-416
    • /
    • 2001
  • Distance relay is the most widely used in transmission line protection because it is applicable not only as main protection but also as back-up protection. However, the protection range of the distance relay is always fixed in the unchangeable operating range while the power system varies, and therefore the distance relay is the device that is the highly influenced by the power system changes. In this regard, this paper describes an approach to minimize the mal-operation of the distance relay due to the power system changes through changing protection range of the distance relay into optimal condition in response to the load variation and power system condition. Also mal-function of the distance repay in case of high resistance ground faults could be minimized through modeling the protection range into quadratic function.

  • PDF

Analysis and Simulator Design of Portable Microwave Digital FPU Transmission System (M/W대역 디지털 방송중계용 FPU 무선전송 시스템 분석과 시뮬레이터 설계)

  • 강희조;조성언;최용석
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.658-666
    • /
    • 2003
  • In this paper, we analyzed standard and characteristic of portable microwave digital FPU(Field Pick Up) transmission system in AWGN channel environment as basis step of research about share way of M/W broadcasting relay frequency. And we analyzed system performance through simulator design. Domestic case, digitize progress about broadcasting relay is propeled. Therefore, we wish to utilize to basis data about interference evaluation and domestic broadcasting relay standardization for reassignment of M/W band broadcasting relay frequency.