• Title/Summary/Keyword: digital relay

Search Result 272, Processing Time 0.033 seconds

Construction of Intelligent Substation for 154kV Class (154kV급 인텔리전트 변전소 구축)

  • Chung, Y.H.;Yang, D.I.;Kim, J.B.;Choi, I.H.;Kim, J.H.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.129-130
    • /
    • 2005
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(DCP) replaces local panel which is drived by mechanical operation. For monitoring rendition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

Intelligent Substation Construction of 154kV Class (154kV 인텔리전트 변전소 구축)

  • Kim J B.;Chung Y. H.;Song W. P.;Choi I. H.;Kim J. H.;Lee D. I.;Koh H. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.524-526
    • /
    • 2004
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(UP) replaces local panel which is drived by mechanical operation. For monitoring condition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

The Development of Electronic Transformer for 245kV GIS (245kV GIS용 전자식변성기 개발)

  • Kim, Young-Min;Kim, Min-Soo;Kim, Jung-Bae;Lee, Hahk-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.373-374
    • /
    • 2008
  • 지금까지 변전소나 발전소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital 화가 진전되어져 있다. 또한, Digital Network로 총합한 Intelligent 변전소가 시범적으로 구축되어짐에 따라 Digital Network에 대응한 초고압용 신형 CT, VD가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 기존의 CT.PT의 단점을 보완할 수 있는 245kV GIS용 로고스키코일형 CT와 Capacitive Voltage Divider를 개발 중에 있으며, 센서 자체의 특성시험에서 IEC 60044-7, 8 1Class 기준을 만족하는 특성을 얻을 수 있었다. 이러한 신형 CT.VD의 적용으로 종래의 CT.PT가 차지하는 공간이 필요 없게 되어 컴팩트한 GIS의 구조가 가능하게 될 것이다.

  • PDF

The Development of Electronic Transformer(CT/PT) for Intelligent GIS Based on IEC 60044 (IEC 60044 기반 Intelligent GIS용 전자식 변성기 개발)

  • Kim, M.S.;Jung, J.R.;Kim, J.B.;Song, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2262-2264
    • /
    • 2005
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어지고 있으며, Digital Network에 대응한 변성기 관련규격인 IEC 60044가 근래 제정되어짐에 따라 이에 적합한 전자식 변성기가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 IEC 60044를 기반으로 한 전자식변성기 Layout을 구성하였으며, CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.661-662
    • /
    • 2007
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this paper, we mention the synopsis and report the progress state of project.

  • PDF

Digital Voice Ground Wave Range Analysis of HF Radios that Applied MELPe CODEC Using GRWAVE Program (MELPe 코덱이 적용된 HF 무전기의 GRWAVE 분석 툴을 이용한 디지털 음성 지상파 통달거리 분석)

  • Heo, Jin;Lee, Sangjin;Lee, Kangchun;Seo, Sungwon;Kim, Jungsup;Han, Sungwoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.431-440
    • /
    • 2017
  • HF communications are used as a last means of long distance communications without any relay node in NLOS (Non Line-Of-Sight) environment. Conventional analog voice communication in the HF band is vulnerable to security as well as severe background noise. To overcome these shortcoming, digital voice was introduced into HF radios in the early 1980s. In this paper, we analyze avaliable digital voice communication ground wave range of HF radios that applied MELPe CODEC and MIL-STD-188-110B physical layer standard using GRWAVE program. And we evaluate usefulness of digital voice communication in HF band.

A Study on the Intelligent High Voltage Switchboard for Custormer (고압 수용가용 배전반의 intelligent화 연구)

  • Byun, Young-Bok;Joe, Ki-Youn;Koo, Heun-Hoi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.444-446
    • /
    • 1994
  • This paper describes the design of a digital multifunction controller for the intelligent high voltage customer switchboard and proposes a relaying algorithm for high impedance faults using back-propagation neural network. The hardware design uses the three microprocessors and global memory architecture to achive real time operation and control 4 feeders. The controller uses a 64-point radix-4 DIF FFT algorithm to measure the harmonic and relay parameters. Synthesized fault current waveforms are used to train and test the back - propagation network.

  • PDF

UPnP Protocol Extension for Contents Sharing among Digital Home Networks (디지털 홈 네트워크 간 콘텐츠 공유를 위한 UPnP 확장 기법)

  • 이현룡;김종원
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10c
    • /
    • pp.151-153
    • /
    • 2004
  • 홈 네트워크의 보급과 P2P 기반의 커뮤니티가 활성화되는 추세로 미루어 볼 때 가까운 장래에 사용자들은 홈 네트워크에 기반한 커뮤니티를 형성하길 원할 것으로 예측되며, 이를 지원하기 위해 표준에 근간한 접근 방법이 제시되어야 한다. 따라서 본 논문에서는 홈 네트워킹을 위한 대표적인 프로토콜인 UPRP 에 기반하여 홈 네트워크간의 콘텐츠 공유를 지원하는 방안을 모색한다. UPnP포럼에서 정의하는 표준 기능에 UPnP프로토콜의 특성을 이용한 RelayModule을 구현하고 추가함으로 UPnP에 기반한 홈 네트워크 사이의 연결을 지원하고 더 나아가 디지털 콘텐츠 공유를 지원한다.

  • PDF

An optimal operation algorithm for implementation of digital protection relay (디지털 보호계전기 구현을 위한 최적 연산 알고리즘)

  • Kim, D.H.;Seo, J.W.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.259-261
    • /
    • 2003
  • 오늘날 상용화되어 있는 디지털 주파수 계전기는 교차된 시스템 전압의 양단이 0 으로 되는 동안의 시간을 측정하여 주파수를 얻는다. 이러한 계전기의 동작은 왜곡된 고조파와 노이즈로 인하여 주파수 측정을 잘못하는데 이로 인해 zoro crossing이 변하거나 증가된 zero crossing이 생성된다. 최근 몇몇의 디지털 주파수 계전기 알고리즘이 제안되었다. 본 논문에서도 역시 보다 정확하면서 고속데이터 처리가 가능하도록 보호 계전기 연산에 사용되는 알고리즘을 최적화하고자 한다.

  • PDF

Development of fault wave analysis program for digital protection relay (디지털 보호계전기 사고파형 분석 프로그램 개발)

  • Park, Chang-Sun;Kim, Hyun-Sung;Cho, Pil-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.513-514
    • /
    • 2007
  • 최근 들어, 디지털 보호 계전기의 계측 및 계전 기능 외에 운용 프로그램 및 사고파형 분석 기능 또한 중요시 하고 있는 실정이다. 이를 위해 저장된 사고파형을 분석하기 위한 프로그램 개발이 요구되어 지고 있으며 본 논문에서는 다양한 기능을 가지는 사고파형 분석 프로그램을 소개한다.

  • PDF