• Title/Summary/Keyword: digital reference

Search Result 1,291, Processing Time 0.023 seconds

Design of a step-up DC-DC Converter using a 0.18 um CMOS Process (0.18 um CMOS 공정을 이용한 승압형 DC-DC 컨버터 설계)

  • Lee, Ja-kyeong;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.715-720
    • /
    • 2016
  • This paper proposes a PWM (Pulse Width Modulation) voltage mode DC-DC step-up converter for portable devices. The converter, which is operated with a 1 MHz switching frequency, is capable of reducing the mounting area of passive devices, such as inductor and capacitor, and is suitable for compact mobile products. This step-up converter consists of a power stage and a control block. The circuit elements of the power stage are an inductor, output capacitor, MOS transistors Meanwhile, control block consist of OPAMP (operational amplifier), BGR (band gap reference), soft-start, hysteresis comparator, and non-overlap driver and some protection circuits (OVP, TSD, UVLO). The hysteresis comparator and non-overlapping drivers reduce the output ripple and the effects of noise to improve safety. The proposed step-up converter was designed and verified in Magnachip/Hynix 0.18um 1-poly, 6-metal CMOS process technology. The output voltage was 5 V with a 3.3 V input voltage, output current of 100 mA, output ripple less than 1% of the output voltage, and a switching frequency of 1 MHz. These designed DC-DC step-up converters could be applied to the Personal Digital Assistants(PDA), cellular Phones, Laptop Computer, etc.

Shallow-depth Tilt Monitoring for Engineering Application (공학적 활용을 위한 천부지반 틸트 모니터링)

  • 이상규
    • The Journal of Engineering Geology
    • /
    • v.3 no.3
    • /
    • pp.279-293
    • /
    • 1993
  • In recent yeaes, the collapses of man made structures have been encountered from time to time due to the deformation of the ground in korea. Furthermore, the possibilities of casasters from the ground deformation suCh as landslide and active fault are atrracting our attention to the deformation monitoring. In this study, two-coordinate tilt which was monitored during six months in order to develop tediniques for prevention of disasters from the ground deformation. The two-coordinate tilt which was detected by a tilt-sensor installed in shallow depth on the slope with the sensitivity of 0.0001 arc.sec in every 10 minutes was recorded continously to PC through the interface with 200-m line coonection. The observed digital tilt data. together with the relevant meteorological data were analyzed in reference to engineering application. During the whole observation period of six months, the net tilt is 10.06 arc.sec to the west and 73.88 arc.sec to the south. Consequently the ground has a tilt of 74.56 arc.sec to the direction of $S7.75^{\circ}W$ with average tilting of 0.02 arc.sec/hour. In spite of such fast and large tilting, it is interpreted in view of engineering aspects that the site is much safe from danger, since both East-West and North-South components of tilt converge as time goes by. Two categories of deformational events are recognized ; one is toward the direction of surface slope and the other is to the direction of increased pore pressure. Tiks are acenain to have a close relation with precipitation of rain. The daily variation of two-coordinate tilt is delayed 4.3 hours in average after the variation of atmospheric temperature. A certain correlation between atmospheric pressure and deformation might be revealed.

  • PDF

ANALYSIS ON THE PREDICTOR OF DISEASE PROGRESSION IN REFRACTORY PERIODONTITIS (난치성 치주염의 질환진행 예견 인자에 관한 분석)

  • Lee, Hae-Joon;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.109-126
    • /
    • 1993
  • Refractory periodontitis manifest progressive attachment loss in a rapid and unrelenting manner regardless of the type or frequency of therapy applied. The purpose of this study was ta evaluate the relation between the level of cytokines in GCF and periodontopathic microflora with disease activity of refractory periodontitis. Selection of patients with refractory periodontitis (7 males, 3 females) were made by long term clinical observation including conventional clinical history and parameters. Teeth that showed pocket depth greater than 6mm were selected as sample teeth. Subjects were examined at baseline and after 3 months. Prior to baseline test, individual acrylic stent was fabricated. Reference grooves were made on each sample tooth site. Pocket depth and attachment loss were measured by Florida Probe. Gingival index was measured at 4 sites each sample teeth. Disease activity was defined as attachment loss of ${\ge}$ 2.1mm, as determined by sequential probing and tolerance method. The pattern and amount of alveolar bone resorption was observed with quantitative digital subtraction image processing radiography. Morphological analysis of subgingival bacteria was taken by phase contrast microscopy. Predominant cultivable bacterial distribution and frequency were compared between disease-active and disease-inactive site using immunofluorescence microscopy and selective microbial culturing. Levels of $interleukin-l{\beta}$, 2, 4, 6 and $TNF-{\alpha}$ in GCF and blood serum sample were quantified by ELISA. In active sites, P. intermedia was significantly increased to compare with inactive site. $IL-1{\beta}$, IL-2, IL-6 and $TNF-{\alpha}$ in GCF were increased in active sites and IL-2 in serum was increased in active patients significantly. Alveolar bone loss in active site was correlated with $IL-1{\beta}$, IL-2 in GCF. And loss of attachment in active site was correlated with IL-2 in GCF. These results demonstrate that IL-2 in serum, $IL-1{\beta}$, IL-2, IL-6 and $TNF-{\alpha}$ in GCF, P, intermedia might be used as possible predictors of disease activity in refractory periodontitis before it is clinically expressed as attachment loss and quantitative alveolar bone change.

  • PDF

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.

Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation (치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구)

  • Park, Ju-Hee;Seol, Jeong-Hwan;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.104-115
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the image acquisition ability of intraoral scanners by analyzing the comprehensiveness of scanned images from standardized model, and to identify problems of the model. Materials and Methods: Cast models and 3D-printed models were prepared according to international standards set by ISO12836 and ANSI/ADA no. 132, which were then scanned by model scanner and two different intraoral scanners (TRIOS3 and CS3500). The image acquisition performance of the scanners was classified into three grades, and the study was repeated with varying surface conditions of the models. Results: Model scanner produced the most accurate images in all models. Meanwhile, CS3500 showed good image reproducibility for angled structures and TRIOS3 showed good image reproducibility for rounded structures. As for model ingredients, improved plaster model best reproduced scan images regardless of the type of scanner used. When limited to 3D-printed model, powdered surface condition resulted in higher image quality. Conclusion: When scanning structures beyond FOV (field of view) in standardized models (following ISO12836 and ANSI/ADA 132), lack of reference points to help distinguish different faces confuses the scanning and matching process, resulting in inaccurate display of images. These results imply the need to develop a new standard model not confined to simple pattern repetition and symmetric structure.

Evaluation of Mobile Device Based Indoor Navigation System by Using Ground Truth Information from Terrestrial LiDAR

  • Wang, Ying Hsuan;Lee, Ji Sang;Kim, Sang Kyun;Sohn, Hong-Gyoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.5
    • /
    • pp.395-401
    • /
    • 2018
  • Recently, most of mobile devices are equipped with GNSS (Global Navigation Satellite System). When the GNSS signal is available, it is easy to obtain position information. However, GNSS is not suitable solution for indoor localization, since the signals are normally not reachable inside buildings. A wide varieties of technology have been developed as a solution for indoor localization such as Wi-Fi, beacons, and inertial sensor. With the increased sensor combinations in mobile devices, mobile devices also became feasible to provide a solution, which based on PDR (Pedestrian Dead Reckoning) method. In this study, we utilized the combination of three sensors equipped in mobile devices including accelerometer, digital compass, and gyroscope and applied three representative PDR methods. The proposed methods are done in three stages; step detection, step length estimation, and heading determination and the final indoor localization result was evaluated with terrestrial LiDAR (Light Detection And Ranging) data obtained in the same test site. By using terrestrial LiDAR data as reference ground truth for PDR in two differently designed experiments, the inaccuracy of PDR methods that could not be found by existing evaluation method could be revealed. The firstexperiment included extreme direction change and combined with similar pace size. Second experiment included smooth direction change and irregular step length. In using existing evaluation method which only checks traveled distance, The results of two experiments showed the mean percentage error of traveled distance estimation resulted from three different algorithms ranging from 0.028 % to 2.825% in the first experiment and 0.035% to 2.282% in second experiment, which makes it to be seen accurately estimated. However, by using the evaluation method utilizing terrestrial LiDAR data, the performance of PDR methods emerged to be inaccurate. In the firstexperiment, the RMSEs (Root Mean Square Errors) of x direction and y direction were 0.48 m and 0.41 m with combination of the best available algorithm. However, the RMSEs of x direction and y direction were 1.29 m and 3.13 m in the second experiment. The new evaluation result reveals that the PDR methods were not effective enough to find out exact pedestrian position information opposed to the result from existing evaluation method.

Geocoding of the Free Stereo Mosaic Image Generated from Video Sequences (비디오 프레임 영상으로부터 제작된 자유 입체 모자이크 영상의 실좌표 등록)

  • Noh, Myoung-Jong;Cho, Woo-Sug;Park, Jun-Ku;Kim, Jung-Sub;Koh, Jin-Woo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.249-255
    • /
    • 2011
  • The free-stereo mosaics image without GPS/INS and ground control data can be generated by using relative orientation parameters on the 3D model coordinate system. Its origin is located in one reference frame image. A 3D coordinate calculated by conjugate points on the free-stereo mosaic images is represented on the 3D model coordinate system. For determining 3D coordinate on the 3D absolute coordinate system utilizing conjugate points on the free-stereo mosaic images, transformation methodology is required for transforming 3D model coordinate into 3D absolute coordinate. Generally, the 3D similarity transformation is used for transforming each other 3D coordinates. Error of 3D model coordinates used in the free-stereo mosaic images is non-linearly increased according to distance from 3D model coordinate and origin point. For this reason, 3D model coordinates used in the free-stereo mosaic images are difficult to transform into 3D absolute coordinates by using linear transformation. Therefore, methodology for transforming nonlinear 3D model coordinate into 3D absolute coordinate is needed. Also methodology for resampling the free-stereo mosaic image to the geo-stereo mosaic image is needed for overlapping digital map on absolute coordinate and stereo mosaic images. In this paper, we propose a 3D non-linear transformation for converting 3D model coordinate in the free-stereo mosaic image to 3D absolute coordinate, and a 2D non-linear transformation based on 3D non-linear transformation converting the free-stereo mosaic image to the geo-stereo mosaic image.

A Study on Relativity between Shi-Dong-Bing(是動病) and Five Su Points Related Symptoms of Liver Meridian of Foot Gworeum(足厥陰肝經) -Based on the Study of Zhen Jiu Jia Yi jing(鍼炎甲乙經)- (족궐음간경(足厥陰肝經) 오수혈 주치(主治)의 특성(特性)과 시동병(是動病)의 연관성(聯關性)에 관한 연구(硏究) -<침구갑을경(鍼灸甲乙經)>을 중심(中心)으로-)

  • Sung, Su-Min;Lee, Seong-Su;Oh, Se-Hyoung;Hwang, Min-Sub;Yoon, Jong-Hwa
    • Journal of Acupuncture Research
    • /
    • v.23 no.3
    • /
    • pp.57-65
    • /
    • 2006
  • Objectives : It is known that the five Su points are very useful clinically. The following study was undertaken in order to find out the general characteristic and the origin of the five Su points. Methods: We investigated the relation of symptoms that are treated by five Su points and Shi-Dong Suo-Sheng-Bing(是動 所生病). The main reference book was Zhen Jiu Jia Yi jing(鍼灸甲乙經) and the author took Liver Meridian of Foot Gworeum(足厥陰肝經) as an example. Results : 1. Five Su point of Liver Meridian of Foot Gworeum(足厥陰肝經) treats Shi-Dong-Bing(是動病) of Liver Meridian of Foot Gworeum. It is peculiarity of Five Su point of Liver Meridian of Foot Gworeum, differed from the others acupoints. Symptoms of Shi-Dang-Bing appears with the abnormal pulsation of Merdian Gi(脈氣), and the special feature of Shi-Dang-Bing is the symptoms are consisted of disorders of whole body, trobles of an internal organ, and psychosomatic disorders. 2. In , it is described the part of pulse feeling for Shi-Dong-Bing(是動病) of Liver Meridian of Foot Gworeum(足厥陰肝經) as ‘A region that is 2 Chon(寸) from the basic digital joint of the first toe’. This region is agree with the acupoint of Liver Meridian of Foot Gworeum in , . And Haeng-gan(行間) Tae-chung(太衝), members of five Su-points of Liver Meridian of Foot Gworeum is situated the same region. So we suppose that the part of pulse feeling for Shi-Dong-Bing of Liver Meridian of Foot Gworeum is transformed into Haeng-gan(行間) Tae-chung(太衝), among the five Su points.

  • PDF

An Optimum Scale for Topoclimatic Interpolation of Daily Minimum Temperature in Complex Terrain (일 최저기온 공간내삽을 위한 지형기후학적 최적 공간규모)

  • 정유란;서희철;윤진일;이광회
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.4
    • /
    • pp.261-265
    • /
    • 2003
  • Cold air accumulation plays a critical role in formulating daily minimum temperature in complex terrain on radiative cooling nights, and spatial interpolation can be improved by accommodating this important topoclimatic variable. Little is known about the spatial scale for computing cold air accumulation which influences daily minimum temperature. Air temperature was measured at 10-minute intervals during September 2002- February 2003 at eight locations within a 1 by 1 km hilly orchard area. Minimum temperature data for suspected radiative cooling nights were collected, and the deviations from reference observations at a near-by KMA automated weather station were calculated. A digital elevation model with a 10m cell size was used to calculate the cold air accumulation at 8 locations. Zonal averages of the cold air accumulation were computed for each location by increasing the cell radius from 1 to 10. Temperature deviations were regressed to a common logarithm of the smoothed averages of cold air accumulation to derive a linear relationship between the local temperature deviation and the site topography. The highest coefficient of determination ($r^2$ = 0.78) was found at a cell radius of 5, which corresponds to an approximately 1 ha boundary surrounding the point of interest.

Low Complexity Motion Estimation Based on Spatio - Temporal Correlations (시간적-공간적 상관성을 이용한 저 복잡도 움직임 추정)

  • Yoon Hyo-Sun;Kim Mi-Young;Lee Guee-Sang
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.9
    • /
    • pp.1142-1149
    • /
    • 2004
  • Motion Estimation(ME) has been developed to reduce temporal redundancy in digital video signals and increase data compression ratio. ME is an Important part of video encoding systems, since it can significantly affect the output quality of encoded sequences. However, ME requires high computational complexity, it is difficult to apply to real time video transmission. for this reason, motion estimation algorithms with low computational complexity are viable solutions. In this paper, we present an efficient method with low computational complexity based on spatial and temporal correlations of motion vectors. The proposed method uses temporally and spatially correlated motion information, the motion vector of the block with the same coordinate in the reference frame and the motion vectors of neighboring blocks around the current block in the current frame, to decide the search pattern and the location of search starting point adaptively. Experiments show that the image quality improvement of the proposed method over MVFAST (Motion Vector Field Adaptive Search Technique) and PMVFAST (Predictive Motion Vector Field Adaptive Search Technique) is 0.01~0.3(dB) better and the speedup improvement is about 1.12~l.33 times faster which resulted from lower computational complexity.