• Title/Summary/Keyword: digital reference

Search Result 1,291, Processing Time 0.033 seconds

A Simplified Synchronous Reference Frame for Indirect Current Controlled Three-level Inverter-based Shunt Active Power Filters

  • Hoon, Yap;Radzi, Mohd Amran Mohd;Hassan, Mohd Khair;Mailah, Nashiren Farzilah;Wahab, Noor Izzri Abdul
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1964-1980
    • /
    • 2016
  • This paper presents a new simplified harmonics extraction algorithm based on the synchronous reference frame (SRF) for an indirect current controlled (ICC) three-level neutral point diode clamped (NPC) inverter-based shunt active power filter (SAPF). The shunt APF is widely accepted as one of the most effective current harmonics mitigation tools due to its superior adaptability in dynamic state conditions. In its controller, the SRF algorithm which is derived based on the direct-quadrature (DQ) theory has played a significant role as a harmonics extraction algorithm due to its simple implementation features. However, it suffers from significant delays due to its dependency on a numerical filter and unnecessary computation workloads. Moreover, the algorithm is mostly implemented for the direct current controlled (DCC) based SAPF which operates based on a non-sinusoidal reference current. This degrades the mitigation performances since the DCC based operation does not possess exact information on the actual source current which suffers from switching ripples problems. Therefore, three major improvements are introduced which include the development of a mathematical based fundamental component identifier to replace the numerical filter, the removal of redundant features, and the generation of a sinusoidal reference current. The proposed algorithm is developed and evaluated in MATLAB / Simulink. A laboratory prototype utilizing a TMS320F28335 digital signal processor (DSP) is also implemented to validate effectiveness of the proposed algorithm. Both simulation and experimental results are presented. They show significant improvements in terms of total harmonic distortion (THD) and dynamic response when compared to a conventional SRF algorithm.

Product-Sharing and Outcome Generation: New Contributions of Libraries to Research, Learning and Professional Development in Japanese Context

  • Oda, Mitsuhiro
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.45 no.2
    • /
    • pp.61-74
    • /
    • 2011
  • The author analyses the challenging activities of Japanese libraries in this decade by launching two keywords; "product-sharing" and "outcome generation." "Product-sharing" means that libraries share knowledge, skills, and records which are produced as the result of the services or in the process of activities. And "outcome generation" means that libraries generate any efficiency or effectiveness through their services to users. Using these concepts, reported are the current situation and aspects of Japanese libraries which try to make various contributions to the society; research and learning of the people, and education and training for professional librarians, and so on. In the analysis, the author shows some examples of "product-sharing" at first, including the records of reference transaction and the multi-functioned online public access catalogue. Especially, focused is on the various possibility and adoptability of the Collaborative Reference Database System of the National Diet Library of Japan. This system is one of digital reference service in Japan, and the database of reference transaction records is expected to be useful for research and academic studyies as knowledge-base of professional librarians. And the system is also expected to be a platform for LIS education and professional development in the e-learning environment. Secondly, as the examples of "outcome generation", explained are the problem-solving-type activities, and provision of the collection about books on struggling against disease and illness. A few examples of outcome in the problem-solving-type activities are these; increase of sales in the services for shop managers, business persons, and entrepreneurs, contribution to affluent daily life by providing the local information services to residents and neighbourhoods, and etc. And for both the patients with serious cases and their family or those who nurse them, books about other persons' notes or memorandum are the greatest support, and sometime healing. The author discuss the 'raison d'etre' of these activities focusing on public libraries in Japan.

Side Information Transmission using Reference Symbol in PTS Scheme (PTS 방식에서 기준 심볼을 이용한 부가정보 전송)

  • 유흥균;박종현;박진수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.4
    • /
    • pp.414-420
    • /
    • 2004
  • Partial transmit sequence(PTS) scheme has been widely studied to reduce the peak-to-average power ratio(PAPR) of Orthogonal frequency-division multiplexing(OFDM) signal since it is flexible ad any spectral regrowth is not made. A necessity of the PTS scheme is to transmit the side information about the phase rotation factors for correct OFDM symbol recovery. In this paper, a new side information embedded PTS scheme using the reference symbols is proposed fur the PAPR reduction and the BER(bit error rate) performance is analyzed when the erroneous side information is received. In this proposed method, the information about the rotation factors is expressed by the phase of reference symbols. The proposed method maintains the same PAPR reduction performance as the conventional PTS scheme and OFDM symbols are correctly recovered by the side information to meet the required BER level, which is verified via the computer simulation. Also, it is shown that the proposed method can be easily realized and can be used for all kinds of digital modulation formats in the OFDM communication system.

Design of Ubiquitous Reference Point for Location Service (위치정보 제공 서비스를 위한 유비쿼터스 기준점 설계 연구)

  • Park, Jae-Min;Oh, Yoon-Seuk;Kang, Jin-A;Kim, Byung-Guk
    • Spatial Information Research
    • /
    • v.15 no.3
    • /
    • pp.301-310
    • /
    • 2007
  • There are 21,000 National Surveying Control Points (NSCP) made of stone for precise surveying nationwide. NSCPs that provide location information are usually buried at the top of a mountain for view points that cannot be used by the public. Recently, according to the growing ubiquitous computing generation, location-based information has become very important and a service that can be easily accessed by the public is needed. In this research, a new type of reference point for a location information service is proposed. It is an Intelligent Reference Point (IRP) equipped with RFID tags and a two-dimensional bar-code system. The IRP system is composed of an electronic tag component, a tag identification component, and an IRP service component. We designed the IRP receiver identifying RFID tag and two-dimensional barcode was designed using a PDA, digital camera, and an RFID receiver. Also designed was IRP input data and input information. Furthermore, the operation software was developed in a PDA for identifying IRP and using IRP the service, and the IRP positioning method was developed using a GIS spatial analysis.

  • PDF

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

Design and Implementation of Library Chatbot for Non-face-to-face Reference Services (비대면 참고정보서비스를 위한 도서관 챗봇 설계 및 구현 연구)

  • Yoo, Jiyoon
    • Journal of the Korean Society for information Management
    • /
    • v.37 no.4
    • /
    • pp.151-179
    • /
    • 2020
  • This study explores the potential of using a library chatbot to improve the non-face-to-face digital reference services for academic library users by designing and implementing a library chatbot. Through data analysis, user needs and library services were analyzed, and a scenario was designed by selecting an appropriate development method. For user-friendly interaction, the personality of the chatbot and user interface was designed to evaluate its usability. In addition, the accuracy was verified through the response accuracy evaluation and performance evaluation of the chatbot, and the effectiveness of the chatbot was evaluated through a user satisfaction survey. In order to manage the operation and maintain service quality, the chatbot is improved by monitoring user-chatbot conversations and reflecting user feedback. Based on these findings, recommendations for designing and implementing a library chatbot were made to help improve library reference services.

Color assessment of resin composite by using cellphone images compared with a spectrophotometer

  • Rafaella Mariana Fontes de Braganca;Rafael Ratto Moraes ;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.23.1-23.11
    • /
    • 2021
  • Objectives: This study assessed the reliability of digital color measurements using images of resin composite specimens captured with a cellphone. Materials and Methods: The reference color of cylindrical specimens built-up with the use of resin composite (shades A1, A2, A3, and A4) was measured with a portable spectrophotometer (CIELab). Images of the specimens were obtained individually or pairwise (compared shades in the same photograph) under standardized parameters. The color of the specimens was measured in the images using RGB system and converted to CIELab system using image processing software. Whiteness index (WID) and color differences (ΔE00) were calculated for each color measurement method. For the cellphone, the ΔE00 was calculated between the pairs of shades in separate images and in the same image. Data were analyzed using 2-way repeated-measures analysis of variance (α = 0.05). Linear regression models were used to predict the reference ΔE00 values of those calculated using color measured in the images. Results: Images captured with the cellphone resulted in different WID values from the spectrophotometer only for shades A3 and A4. No difference to the reference ΔE00 was observed when individual images were used. In general, a similar ranking of ΔE00 among resin composite shades was observed for all methods. Stronger correlation coefficients with the reference ΔE00 were observed using individual than pairwise images. Conclusions: This study showed that the use of cellphone images to measure the color difference seems to be a feasible alternative providing outcomes similar to those obtained with the spectrophotometer.

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

Refractive media flatness measurement by phase shifting digital holography (위상천이 디지털 홀로그래피를 이용한 평판의 표면 평면도 측정)

  • Jeon, Sung-Bin;Kim, Do-Hyung;Cho, Jang-Hyun;Park, No-Cheol;Yang, Hyun-Seok;Park, Kyoung-Su;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.2
    • /
    • pp.44-49
    • /
    • 2012
  • We measured the surface flatness of both sides for refractive media using the transmitted digital holography method. To enhance the accuracy of the result, phase-shifting system was used. With two different phase modulation of reference beam, the phase profile of object can be easily obtained. Thus, we proposed the surface measurement method which can measure large area fast, compared with conventional methods. To guarantee the reliability of obtained result, we compared with Zygo measurement system. With the proposed method, the surface flatness of $3.45{\mu}m$ resolution could be obtained.

Assessment of Cancellous Bone of Mandible by Multifunctional Panoramic X-Ray Machine (다기능 파노라마 방사선촬영장치를 이용한 하악해면골질의 평가)

  • Ko Jae-Kyung;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2000
  • Purpose : To evaluate the bone densities measured on copper-equivalent image of cross sectional view of mandibular edentulous premolar area obtained by multifuctional panoramic x-ray machine, PM 2002 CC with transversal slicing system. Materials and Methods: Panoramic cross sectional views with 8 mm focal layer of aluminum step and blocks, of hydroxyapatite (RA) step, 6 HA blocks and copper step wedge having 0.03 mm thickness of each step, and of 3 bone blocks cutted by 8 mm thickness mesiodistally and a dry mandible with copper step wedge were taken by using transversal slicing system in PM 2002 Cc. All reference-equivalent images were made and analyzed by NIH image program. Results: The average copper-equivalent value of cancellous bone of bone blocks on the panoramic cross sectional view was 0.026 ± 0.020 mm Cu. The calculated average bone density was 0.38g/cm². There was no significant difference (P>0.1) between the bone densities on intraoral digital view and on the panoramic digital cross sectional view. Conclusion: The copper-equivalent image of panoramic digital cross sectional view obtained by PM 2002 CC with very thin copper step wedge was supposed to be useful to measure the bone density of cancellous bone of mandible at the premolar edentulous area.

  • PDF