• Title/Summary/Keyword: digital reference

Search Result 1,283, Processing Time 0.03 seconds

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

An Hybrid Approach to Improve the Standard Classification System in the Domains of Economics, Humanities, and Social Science (하이브리드 방식에 의한 경제.인문.사회 분야 표준분류체계 개선에 관한 연구)

  • Chung, Eun-Kyung;Park, Ji-Yeon
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.20 no.3
    • /
    • pp.129-147
    • /
    • 2009
  • The ultimate goal of classification systems is to provide tools for information management and services through collocation of information objects in similar topics. The National Research Council for Economics, Humanities, and Social Sciences(NRCS) aims to organize the research products from 23 research institutes. To manage and organize the research products effectively, the standard classification system has been developed in conjunction of users' survey and the Business Reference Model(BRM). Although the standard classification system consists of users' perspectives and the aspects of organizational functions, there are limits to apply the system into classification practices. In this study, the proposed hybrid approach is to combine a clustering approach with 1,884 keywords from the titles of research products between 2007 and 2008. The clustering approach is performed in a heuristic way according to the KDC due to the lack of digital full texts of research products. The results of this study proposed a revised standard classification system for NRCS with 16 headings and 90 sub-headings. The revised standard classification system will play an important role in managing research products effectively.

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

  • Dae-Sung Kim;So-Hyung Park;Jong-Ju Ahn;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.271-280
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS. Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS. Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION. In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.

Diagnosis of Unruptured Intracranial Aneurysms Using Proton-Density Magnetic Resonance Angiography: A Comparison With High-Resolution Time-of-Flight Magnetic Resonance Angiography

  • Pae Sun Suh;Seung Chai Jung;Hye Hyeon Moon;Yun Hwa Roh;Yunsun Song;Minjae Kim;Jungbok Lee;Keum Mi Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.575-588
    • /
    • 2024
  • Objective: Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to high-resolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. Materials and Methods: In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3, respectively. A neurointerventionist established the gold standard with digital subtraction angiography. We compared the performance of HR-MRA, PD-MRA (0.253-mm3 voxel), and PD-MRA (0.23-mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. Results: The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253-mm3 voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%-91.0% versus 66.7%-70.5%; specificity from 93.7%-96.8% versus 58.7%-68.3%; and accuracy from 90.8%-92.9% versus 63.8%-69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253-mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23-mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253-mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820-0.938) than in HR-MRA (0.447-0.510). Conclusion: PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

Factors Affecting the Intention to Adopt Self-Determination Rights of Personal Medical Information (개인의료정보 자기결정권 행사 의도에 영향을 미치는 요인)

  • Yunmo Koo;Sungwoo Hong;Beomsoo Kim
    • Information Systems Review
    • /
    • v.20 no.1
    • /
    • pp.159-177
    • /
    • 2018
  • With an extensive proliferation of information and communication technology, the volume and amount of digital information collected and utilized on the Internet have been increasing rapidly. Also on the rapid rise are side effects such as unintended breach of accumulated personal information and consequent invasion of personal privacy. Informational self-determination is rarely practiced, despite various states' legal efforts to redress data subjects' damage. Personal health information, in particular, is a subcategory of personal information where informational self-determination is hardly practiced enough. The observation is contrasted with the socio-economic inconvenience that may follow due to its sensitive nature containing individuals' physical and health conditions. This research, therefore, reviews factors of self-determination on personal health information while referring to the protection motivation theory (PMT), the long-time framework to understand personal information protection. Empirical analysis of 200 data surveyed reveals threat-appraisal (perceived vulnerability and perceived severity of threats) and coping-appraisal (perceived response effectiveness), in addition to individual levels of concern regarding provided personal health information, influence self-determination to protect personal health information. The research proposes theoretical findings and practical suggestions along with reference for future research topics.

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

A Destructive Method in the Connection of the Algorithm and Design in the Digital media - Centered on the Rapid Prototyping Systems of Product Design - (디지털미디어 환경(環境)에서 디자인 특성(特性)에 관한 연구(硏究) - 실내제품(室內製品) 디자인을 중심으로 -)

  • Kim Seok-Hwa
    • Journal of Science of Art and Design
    • /
    • v.5
    • /
    • pp.87-129
    • /
    • 2003
  • The purpose of this thesis is to propose a new concept of design of the 21st century, on the basis of the study on the general signification of the structures and the signs of industrial product design, by examining the difference between modern and post-modern design, which is expected to lead the users to different design practice and interpretation of it. The starting point of this study is the different styles and patterns of 'Gestalt' in the post-modern design of the late 20th century from modern design - the factor of determination in industrial product design. That is to say, unlike functional and rational styles of modern product design, the late 20th century is based upon the pluralism characterized by complexity, synthetic and decorativeness. So far, most of the previous studies on design seem to have excluded visual aspects and usability, focused only on effective communication of design phenomena. These partial studies on design, blinded by phenomenal aspects, have resulted in failure to discover a principle of fundamental system. However, design varies according to the times; and the transformation of design is reflected in Design Pragnanz to constitute a new text of design. Therefore, it can be argued that Design Pragnanz serves as an essential factor under influence of the significance of text. In this thesis, therefore, I delve into analysis of the 20th century product design, in the light of Gestalt theory and Design Pragnanz, which have been functioning as the principle of the past design. For this study, I attempted to discover the fundamental elements in modern and post-modern designs, and to examine the formal structure of product design, the users' aesthetic preference and its semantics, from the integrative viewpoint. Also, with reference to history and theory of design my emphasis is more on fundamental visual phenomena than on structural analysis or process of visualization in product design, in order to examine the formal properties of modern and post-modern designs. Firstly, In Chapter 1, 'Issues and Background of the Study', I investigated the Gestalt theory and Design Pragnanz, on the premise of formal distinction between modern and post-modern designs. These theories are founded upon the discussion on visual perception of Gestalt in Germany in 1910's, in pursuit of the principle of perception centered around visual perception of human beings. In Chapter 2, I dealt with functionalism of modern design, as an advance preparation for the further study on the product design of the late 20th century. First of all, in Chapter 2-1, I examined the tendency of modern design focused on functionalism, which can be exemplified by the famous statement 'Form follows function'. Excluding all unessential elements in design - for example, decoration, this tendency has attained the position of the international style based on the spirit of Bauhause - universality and regularity - in search of geometric order, standardization and rationalization. In Chapter 2-2, I investigated the anthropological viewpoint that modern design started representing culture in a symbolic way including overall aspects of the society - politics, economics and ethics, and its criticism on functionalist design that aesthetic value is missing in exchange of excessive simplicity in style. Moreover, I examined the pluralist phenomena in post-modern design such as kitsch, eclecticism, reactionism, hi-tech and digital design, breaking away from functionalist purism of modern design. In Chapter 3, I analyzed Gestalt Pragnanz in design in a practical way, against the background of design trends. To begin with, I selected mass product design among those for the 20th century products as a target of analysis, highlighting representative styles in each category of the products. For this analysis, I adopted the theory of J. M Lehnhardt, who gradated in percentage the aesthetic and semantic levels of Pragnantz in design expression, and that of J. K. Grutter, who expressed it in a formula of M = O : C. I also employed eight units of dichotomies, according to the G. D. Birkhoff's aesthetic criteria, for the purpose of scientific classification of the degree of order and complexity in design; and I analyzed phenomenal aspects of design form represented in each unit. For Chapter 4, I executed a questionnaire about semiological phenomena of Design Pragnanz with 28 units of antonymous adjectives, based upon the research in the previous chapter. Then, I analyzed the process of signification of Design Pragnanz, founded on this research. Furthermore, the interpretation of the analysis served as an explanation to preference, through systematic analysis of Gestalt and Design Pragnanz in product design of the late 20th century. In Chapter 5, I determined the position of Design Pragnanz by integrating the analyses of Gestalt and Pragnanz in modern and post-modern designs In this process, 1 revealed the difference of each Design Pragnanz in formal respect, in order to suggest a vision of the future as a result, which will provide systemic and structural stimulation to current design.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

EVALUATION OF RADIOPACITY AND DISCRIMINABILITY OF VARIOUS FIBER REINFORCED COMPOSITE POSTS (수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도 평가)

  • Lee, Eun-Hye;Choi, Hang-Moon;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.188-197
    • /
    • 2010
  • The purpose of this study was to compare radiopacity and radiographic discriminability of various FRC-Posts. Six FRC-Posts were investigated ; 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein), 2) Snowlight (Carbotech, Lewis center, OH, USA), 3) Dentin Post (Komet Brasseler, Lamgo, Germany), 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA), 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA), 6) Luxapost (DMG, Hamburg, Germany) The radiographs of each post with a reference 1 mm / 2 mm aluminum step-wedge was taken using digital sensor. The optical density were calculated by gray value of $10{\times}10$ pixel and compared in mm Al equivalent at five points. Six maxillary incisors of similar radiopacity were used. Radiographs of posts in Mx. incisors of lingual side of dry mandible were taken. We showed radiographs and asked the questionnaire to 3 radiologists, 3 endodontists, 3 general practitioners. The questionnaire was comprised of choices of the highest, lowest radiopaque individual post and the choices of best discriminable post at apical, coronal area. The following results were obtained. 1. Each post system showed various radiopacity. 2. There was change of discriminability between each post and simulated specimens regardless of examiner. Although each post showed various radiopacity, the difference of radiopacity did not affect on discriminability.

A Study on the Performance Verification Method of Small-Sized LTE-Maritime Transceiver (소형 초고속해상무선통신망 송수신기 성능 검증 방안에 관한 연구)

  • Seok Woo;Bu-young Kim;Woo-Seong Shim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.902-909
    • /
    • 2023
  • This study evaluated the performance test of a small-sized LTE-Maritime(LTE-M) transceiver that was developed and promoted to expand the use of intelligent maritime traf ic information services led by the Ministry of Oceans and Fisheries with the aim of supporting the prevention of maritime accidents. Accoriding to statistics, approximately 30% of all marine accidents in Korean water occur with ships weighing less than 3 tons. Therefore, the blind spots of maritime safety must be supplemented through the development of small-sized transceivers. The small transceiver may be used in fishing boats that are active near coastal waters and in water leisure equipment near the coastline. Therefore, verifying whether sufficient performance and stable communication quality are provided is necessary, considering the environment of their real usage. In this study, we reviewed the communication quality goals of the LTE-M network and the performance requirements of small-sized transceivers suggested by the Ministry of Oceans and Fisheries, and proposed a test plan to appropriately evaluate the performance of small-sized transceivers. The validity of the proposed test method was verified for six real-sea areas with a high frequency of marine accidents. Consequently, the downlink and uplink transmission speeds of the small-sized LTE-M transceiver showed performances of 9 Mbps or more and 3 Mbps or more, respectively. In addition, using the coverage analysis system, coverage of more than 95% and 100% were confirmed in the intensive management zone (0-30 km) and interesting zone (30-50 km), respectively. The performance evaluation method and test results proposed in this paper are expected to be used as reference materials for verifying the performance of transceivers, contributing to the spread of government-promoted e-navigation services and small-sized transceivers.