• Title/Summary/Keyword: digital nervous system

Search Result 41, Processing Time 0.027 seconds

Development of Healthcare Bathing System for Improving the Multisensory Functions (복합감각 기능증진 개념의 헬스케어 목욕시스템 개발)

  • Kim, Hyung-Ji;Yu, Mi;Jin, Hea-Ryen;Kwon, Tae-Kyu
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.309-316
    • /
    • 2010
  • This paper proposes healthcare bathing system for improving the multisensory function and not washing. We designed various types of bathtub for developing bathing system. This system consists of whirlpool bathtub for multisensory stimulation, a cover of bathtub with visual-auditory stimulation function, a small size PC for main control, touch panel, digital multimedia broadcasting (DMB), color-changeable LED mood lighting system for improving visual sensibility and speaker. We investigate the effects on autonomic nervous system during bathing with healthcare bathing system for improving the multisensory functions. To analysis physiological parameter, body temperature, blood pressure, intraocular pressure and heart rate variability (HRV) were measured before, during and after bath using healthcare bathing system. Experiments were performed on partial immersion bath and the water temperature was kept $39{\pm}0.5^{\circ}C$. The body temperature and the heart rate variability of the subject were measured every 5 minutes before, during, and after the bath. In analysis of HRV, the parasympathetic nerve increased from starting bath and decreased after 15 minutes. So the subjects felt comfortable at 15 minutes after starting bath. Blood pressure decreased to 16mmHg maximumly however pulse increased. Bath using healthcare bathing system for improving the multisensory functions affects positively the circulation of the blood. From this results, it leaves something to be desired in evaluation of serviceability and physiological analysis using the healthcare bathing system, however, we expect to analyze more clearly the relationship between the serviceability of product, physiological change and sensibility by various physiological parameters.

  • PDF

Analysis of DITI, HRV about the Effect of Far Infrared Radiation Applied to Whole Body('On-tong Therapy') (전신 원적외선 조사요법(온통요법(溫通療法))의 치료 효과에 대한 적외선 체열 분포와 심박변이도 검사 분석)

  • Kim, Min-Young;Ahn, Ji-Yoon;Choi, Seok-Young;Hwang, Deok-Sang;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Chang-Hoon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.94-106
    • /
    • 2013
  • Objectives: The purpose of this study is to find the effect of Far Infrared Radiation (FIR) about improvement of chief complaints and health state. Methods: For this study we evaluated thermographic images, heart rate variability (HRV), visual analogue scale (VAS) score of 34 patients with various diseases. Tests were done two times, before and after treatments and we compared the test results. We used the temperature difference between CV12 and CV4, both sides of PC8, LR3 for recognizing improvement of blood circulation. We analyzed the change of complexity, stability of autonomic nervous system (ANS) by HRV test. The patients were asked to fill out questionnaire about the severity of symptoms by VAS score. Analyses were undertaken using SPSS ver.12.0.1 and p-value of < 0.05 was considered significant. Results: Statistical analysis shows that Far Infrared Radiation (FIR) had significant efficiency in increasing surface temperature and reducing VAS pain scores. In heart rate variability (HRV) test, LF/HF ratio showed tends to improve. Conclusions: The application of an FIR to whole body appears to alleviate various complaints of patients.

A Method for Motion Artifact Compensation of PPG Signal (광혈류량 신호의 움직임 훼손 보상 기법)

  • Kim, Hansol;Lee, Eui Chul
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.543-549
    • /
    • 2013
  • Motion artifacts of central and autonomic nervous system signals degrades the performance of the bio-signal based human factor analysis. Firstly, we propose a defining method of motion artifact section by analyzing successive image frames. Motion artifact section is defined when the amount of motion is greater than the pre-defined threshold. In here, the amount of motion is estimated by first derivation of image frames at temporal domain. Secondly, we propose another defining method of motion artifact section through designing 2D Gaussian probability density function model by analyzing feature vectors of one cycle of signal such as length and amplitude. The defined motion artifact sections are interpolated on the basis of 1D Gaussian function. At result of applying the method into photoplethysmography signal, we confirmed that the calculated heartbeat rate from the restored photoplethysmography came up to the one from electrocardiography. Also, we found that the video based method generated relatively more false acceptance of motion artifact section and the probability density function based method generated relatively more false rejection of motion artifact section.

A Study on Evaluation of Human Arousal Level using PPG Analysis (PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구)

  • Kim, Chi-Jung;Whang, Min-Cheol;Kim, Jong-Hwa;Woo, Jin-Cheol;Kim, Yong-Woo;Kim, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

Videothoracoscopic Sympathectomy in Hyperhidrosis (다한증의 흉강경을 이용한 교감신경절 절제술)

  • 이재영;김명천;조규석
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.279-285
    • /
    • 1998
  • Exessive sweating of the palms and soles, is a psychologically and occupationally distressing and sometimes disabling condition. Hyperhidrosis is one of the common abnormalities in autonomic nervous system. There were no specific treatment on hyperhidrosis, so invasive thoracic sympathectomy via axillary thoracotomy or cervical approach had been used. Video-assisted thoracic surgery(VATS) is now mostly performed for treating of the palmar and axillary hyperhidrosis. From March 1996 to March 1997, 15 patients with bilateral palmar hyperhidrosis had been treated by the bilateral thoracic sympathectomy(T2, T3, T4) with thoracoscopic resection. The patient were evaluated preoperative and postoperative Digital Infrared Thermographic Imaging (DITI) at Kyung-Hee University Hospital. There were no case of the thoracotomy conversion. There were 3 complications ; pulmonary edema in 1 case, Horner's syndrome in 1 case, and gustatory hyperhidrosis in 1 case. More than half of the patients also had compensatory sweating in the lower abdomen, the buttocks, the back and the thighs. In conclusion, most of the patients were satisfied with the postoperative results of the thoracoscopic sympathectomy, including no more palmar and axillary sweating, less pain, better cosmetic appearances, decreased sweating of the face and soles. In addition, intraoperative temperature monitoring of the hands could estimate the successful thoracoscopic sympathectomy and the preoperative and postoperative Digital infrared thermographic imaging(DITI) could especially be the technique for the objective manifestation of the successful results of the thoracoscopic sympathectomy.

  • PDF

Development and Usability Test of the Prototype of the "Smart Stacking Cone" Based on Dual-task Using ICT (ICT를 이용한 이중과제 기반의 스마트 스태킹 콘의 시제품 개발 및 사용성 평가)

  • Lim, Seung-Ju;Won, Kyung-A;Kim, Dae-Gyeom;Kim, Young;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.95-108
    • /
    • 2021
  • Objective : This study aimed to develop prototypes of "smart stacking cones" by combining ICT to evaluate and train the upper extremity function and dual task performance in patients with central nervous system impairment, and to identify the complementary point to the completion of the device through a usability test. Methods : This prototype comprised of a hardware and software system that enabled the evaluation and training of patients and the management of data obtained from patients' performance. Specific measurement variables were established so that patient performance could be measured correctly. Based on the measurement variables, a the prototype included a 'single task evaluation modes', 'dual task evaluation mode', 'single task training mode', and 'dual task training modes'. Additionally, a usability test was conducted to assess clinical applicability and overall satisfaction for the prototype. Results : The results of the usability test were generally found to be appropriate. The 'content adequacy' in the usability test was the area with the highest level of adequacy and the lowest level of inadequacy. Additionally, overall 'satisfaction' in the usability test was the area with the highest appropriate and inappropriate levels. Hence, the overall satisfaction results were unstable. Conclusion : Future studies should be conducted to identify the clinical effectiveness of the device by applying an upgraded smart stacking cone to an actual patient group.

Comparison of Peripheral Blood Flow in Post-Stroke Hemiparetic Patients and Normal Person with Doppler Ultrasonography (도플러 초음파 기기를 이용한 편측 부전마비성 뇌졸중 환자와 정상인의 말초 혈류 비교 연구)

  • Han, Deok-Jin;Bang, Chang-Ho;Kim, Sergey;Bae, Young-Min;Shin, Sae-Ron;Yang, Chung-Yong;Lee, In
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1491-1496
    • /
    • 2009
  • Stroke is usually associated with the cerebral blood flow of the central nervous system. However, studies concerning the effects of neurologic sysmptoms induced from stroke on the peripheral blood flow has not taken place sufficiently. To ascertain the feasibility of a blood flow meter adopting to use doppler ultrasonogrphy, under the prospect that hemiparesis induced from stroke may have effect on the peripheral blood flow, the peripheral blood flow velocity was observed. The control group made up of healthy people without any factors capable of effecting the peripheral blood flow velocity, and patient group which consist of hemiparetic people induced from stroke, were recruited. Volumes of recruitment are 21 persons in the patient group, and 29 persons in the control group, but the final numbers of people are 17 and 21 respectively because of the inconsistancy in the method of the test. The non-invasive method of Doppler effect of Ultrasound was used to measure the blood flow velocity. The blood flow velocity in the peripheral part of left and right fourth fingers:dorsal branches of proper palmar digital artery to dorsum of distal phalanges, was measured in the control group and patient group through Doppler Ultrasound. In comparison of the control group and the patient group, the systolic blood flow velocity from the peripheral part of the upper extremity was lower in the patient group than that of the control group. According to such results, it is concluded that hemiparesis induces the reduction of the peripheral blood flow velocity in the systolic phase.

Risk Analysis of All Types of Cancer among Firefighters and Police Officers Using National Health Insurance Claim Data (건강보험 청구 자료를 이용한 소방 및 경찰공무원의 암 종별 위험도 분석)

  • Lee, Woo-Ri;Yun, Byungyoon;Yoo, Ki-Bong;Yoon, Jin-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.3
    • /
    • pp.242-252
    • /
    • 2022
  • Objectives: Firefighters and police officers are exposed to various occupational hazards. No studies in Korea have investigated the occurrence of cancer by type of cancer for the two occupations. This study aims to investigate the risk of occurrences associated with types of cancers in firefighters and police officers. Methods: Utilizing National Health Insurance(NHI) Claims data from 2006-2015, the study included 8,871,468 general workers, 25,001 firefighters, and 102,274 police officers. Using general workers as a control group, we calculated the standardized incidence ratios(SIR) by types of cancer for firefighters and police officers. After calculating the SIR for all subjects, the SIR was calculated by stratifying according to gender. Results: SIR of colon cancer 1.38(95% CI, 1.11-1.69), cancer of the liver and intrahepatic bile ducts 1.27(95% CI, 1.04-1.54), and 1.88(95% CI, 1.28-2.65) bladder cancer were higher firefighters than general workers. SIR of Lip, oral cavity, and pharynx 1.26(95% CI, 1.07-1.47), Stomach 1.14(95% CI, 1.06-1.23), colon 1.33(95% CI, 1.21-1.46), liver and intrahepatic bile ducts 1.21(95% CI, 1.10-1.32), pancreas 1.24(95% CI, 1.02-1.49), other skin 1.60(95% CI, 1.26-2.00), bladder 1.27(95% CI, 1.04-1.54), other urinary tract 1.46(95% CI, 1.27-1.68), other parts of central nervous system 1.68(95% CI, 1.10-2.46) were higher police officers than general workers. Conclusions: Both firefighters and police officers are exposed to various cancer occurrence risks, necessitating the development of occupational medical protection measures to reduce risk exposure factors.

A research on EEG coherence variation by relaxation (이완에 따른 EEG 코히런스 변화에 대한 연구)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Woo, Jin-Cheol;Kim, Chi-Joong;Kim, Young-Woo;Kim, Ji-Hye;Kim, Dong-Keun
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.121-128
    • /
    • 2010
  • This study is to analyze change of connectivity between brain positions caused by relaxation through EEG coherence. EEG spectrum analysis method has been used to analyze brain activity when relaxation was experienced. However, the spectrum analysis method has a limit that could not observe interactive reaction between brain-functional positions. Therefore, coherence between positions was analyzed to observe connectivity between the measurement positions in this study. Through the method, the reaction of the central nervous system caused by the emotion change was observed. Twenty-four undergraduates of both genders(12 males and 12 females) were asked to close their eyes and listen to the sound. During experiment, EEG was measured at eight positions. The eight positions were F3, F4, T3, T4, P3, P4, O1, and O2 in accordance with International 10-20 system. The sounds with white noise and without were used for relaxation experience. Subjective emotion was measured to verify whether or not they felt relaxation. Subjective emotion of participants were analyzed by ANOVA method(Analysis of Variance). In the result, it was proved that relaxation was subjectively evoked when participants heard sound. Accordingly, it was proved that relaxation could be enhanced by the mixed white noise. EEG coherence between the measurement positions was analyzed. T-test was performed to find its significant difference between relaxation and not-relaxation. In the results of EEG coherence, connectivity with occipital lobes has been increased with relaxation, and connectivity with parietal lobes has been increased with non-relaxed state. Therefore, brain connectivity has shown different pattern between relaxed emotion and non-relaxed emotion.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF