• 제목/요약/키워드: digital intraoral scanner

검색결과 98건 처리시간 0.019초

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례 (Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique)

  • 홍용신;박은진;김선종;김명래;허성주;박지만
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.67-73
    • /
    • 2012
  • 최근 디지털 인상채득 시스템이 개발되면서 이를 기존의 CAD/CAM 시스템과 접목한 인레이, 온레이, 크라운이나 간단한 계속가공의치 등의 고정성 보철물의 제작이 활발히 소개되고 있다. 그러나 임플란트 보철에서는 주로 기존의 아날로그식 인상채득 후 이를 스캔하여 제작하는 방법이 사용되어 왔으나, 구강 내 디지털 스캔한 데이터를 이용하여 나사형 보철물을 제작하는 술식은 아직 활발히 이루어지지 않았다. 이에 본 증례보고에서는 6명의 환자를 대상으로 구강 내 스캐너인 iTero를 사용하여 디지털 스캔을시행한후그중다섯명은맞춤형지대주와 시멘트 합착 후 나사형 임플란트 보철물(screw-retained implant prosthesis after cementation, or SCRP)을 제작하였고, 임상적으로 기능과 심미적인 측면으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

구강스캐너를 이용하여 제작된 CT 가이드 임플란트 수술용 형판의 무치악 거리에 따른 정확도 분석 (Accuracy of the CT guided implant template by using an intraoral scanner according to the edentulous distance)

  • 강병길;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 목적: 이 연구의 목적은 구강스캐너를 이용하여 제작된 임플란트 수술용 형판의 무치악 거리에 따른 정확성을 비교하는 것이다. 재료 및 방법: 방사선불투과성 아크릴 레진을 이용하여 상악 좌우 제2소구치, 제1대구치, 제2대구치 부위를 치아상실 상태로 5개의 상악 모형을 제작하고 각각의 모형을 구강스캐너를 이용하여 가상 모형을 획득하였다. 모형의 술전 CT DICOM file과 가상의 모형을 중첩 후 치아 상실 부위에 임플란트 식립을 계획하였고 제작된 수술용 형판을 이용하여 임플란트 식립 후 술후 CT 촬영을 시행하였다. 술전 CT와 술후 CT를 software상에서 중첩 후 X, Y, Z축을 이용하여 임플란트의 platform과 apex 부위에서, 계획된 임플란트와 실제 식립된 임플란트의 거리 및 각 오차를 측정하고 Kruskall-Wallis test와 Mann-Whitney test를 사용하여 통계분석을 시행하였다. 결과: 임플란트 식립 각도 오차는 제2소구치에서 제2대구치로 갈수록 커졌으나 통계적 차이를 보이지 않았고 platform 부위와 apex부위에서의 식립 거리 오차 또한 제2소구치에서 제2대구치로 갈수록 커지나 제2대구치에서는 통계적으로 유의성 있는 큰 오차를 보였다. 결론: 임플란트 식립 각도에서는 계획된 임플란트와 식립된 임플란트간 통계적 차이는 없었으나 platform과 apex 부위에서의 식립 거리는 제2대구치 부위의 임플란트에서 더 큰 오차를 보였으며 통계적으로 유의할 만한 차이를 보였다.

비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고 (A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report)

  • 박재훈;김지현;서재민;이정진;박연희
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.344-355
    • /
    • 2023
  • 총의치 제작 과정 중 정확한 최종인상을 얻기 위해서는 정확한 예비인상 채득이 선행되어야 한다. 본 증례에서는 비정형적인 악궁 형태를 가진 환자에서 기성 트레이 및 구강 스캐너로 채득하여 제작한 예비모형과 개인트레이를 비교하였다. 58세 남자 환자로 상, 하악 총의치 제작을 위해 본원 구강악안면외과에서 의뢰되었다. 상하악궁 모두 좁고 긴 형태로 비정형적인 형태를 보였다. 기성 트레이를 이용하여 채득한 예비모형은 구강 스캐너를 이용한 예비 모형에 비해 상악의 경우, 협측의 변연이 과연장되었고, 후방 구개 폐쇄 부위에서는 압박되어 있었다. 또한 하악에서도 과연장되었으나, 상악에 비하여 그 양이 많지 않았다. 그리고 구강 스캐너에 의해 채득된 예비모형은 기성 트레이로 채득된 예비 모형에 비해 저연장되었으나, 해부학적 지표는 충분히 인기되었다. 기성 트레이에 의해 제작된 개인 트레이는 IOS에 의해 제작된 개인 트레이에 비하여 구강 내 시적 시, 개인 트레이의 조정량이 많았고 진료 시간이 증가하였다. 본 증례를 통해 비정형적인 악궁을 가진 환자에게 3D 구강 스캐너로 인상을 채득하는 것이 대안이 될 수 있음을 보고하는 바이다.

구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구 (Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height)

  • 정병준;이영후;홍성진;백장현;노관태;배아란;김형섭;권긍록
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.27-35
    • /
    • 2021
  • 목적: 현재 임상에서 스캔바디를 이용한 임플란트의 디지털 인상이 활용되고 있으나 스캔바디의 형태에 따른 스캔의 정확도에 대한 연구는 부족한 실정이다. 본 연구의 목적은 구내 스캔바디의 형태에 따른 스캔의 정확도를 비교하고, 구강 내 노출 높이에 따른 라이브러리 중첩 정확도를 비교하기 위함이다. 재료 및 방법: 덴티폼 상에서 36번 치아를 삭제 후 모델 스캐너로 스캔하여 3D 프린터로 주모형을 출력하였다. 첫 번째 실험으로 세 종류(A, B, C)의 구내 스캔바디를 준비하여 각 그룹마다 다음과 같은 실험을 하였다: 36번 부위에 임플란트를 이상적인 위치로 식립 후 스캔바디를 15 N으로 체결하였다. 스캔바디가 체결된 주모형을 모델 스캐너로 스캔하여 master reference file (대조군)을 STL (Standard Tessellation Language) file로 생성하였다. 이후 구강 스캐너로 10회의 연속적인 스캔을 시행하여 10개의 STL file (실험군)을 생성하였다. 3D 측정 소프트웨어를 이용하여 대조군과 실험군들의 STL file들을 중첩한 후 좌표계 상에서 다음과 같은 값들을 도출하였다: 1) 스캔바디 상 특정 point의 거리 편차 2) 스캔바디 장축의 각도 편차. 두 번째 실험으로는 스캔바디의 구강내 노출 높이에 따른 라이브러리 중첩 정확도를 비교하기 위해 스캔바디 스캔 데이터를 7, 4.5, 2.5, 1.5, 1.0, 0.5 mm 총 6 가지 높이로 준비하여 라이브러리 파일과 중첩하였다. 전체가 노출된 7 mm 데이터를 대조군으로 하여 거리 편차와 각도 편차를 계산하였다. 결과: 첫번째 실험에서 A, B 스캔바디 간(P = .278), B, C 스캔바디 간(P = .568), C, A 스캔바디 간(P = .711) 스캔 파일의 거리 편차 모두 유의한 차이가 나타나지 않았다. A, B 스캔바디 간(P= .568), B, C 스캔바디 간(P = .546), C, A 스캔바디 간(P = .112) 스캔 파일의 각도 편차 또한 모두 유의한 차이가 나타나지 않았다. 또한 스캔바디는 구강 내 노출 높이가 높은 실험군(GH, Gingival Height = 4.5)의 라이브러리 중첩 정확도가 높이가 낮은 실험군(GH = 0.5)보다 통계적으로 유의하게 높았다 (P < .05). 결론: 스캔바디의 각기 다른 형태에 따른 스캔 정확도는 유의한 차이가 없었으며, 스캔바디의 구강 내 노출 높이에 따라 라이브러리 중첩의 정확도는 증가한다. 추후 in vivo 환경에서 더 다양한 형태의 스캔바디를 이용한 후속연구가 필요할 것이다.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

하악골 골염도의 정량적 평가에 관한 비교연구 (A Comparative Study of Quantitative Assessment of Bone Mineral Density of the Mandible)

  • 박원길;최의환;김재덕
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.161-173
    • /
    • 1999
  • This study was performed to compare the bone mineral densities measured at mandibular premolar area by copper-equivalent image and hydroxyapatite phantom with those measured at radius by dual energy absorptiometry and to evaluate the clinical usefulness of Digital system with slide scanner, copper-equivalent image, and hydroxyapatite phantom. For experiment. intraoral radiograms of 15 normal subjects ranged from 20 years old to 67 old were taken with copper-step wedge at mandibular premolar area and bone mineral densities calculated by conversion equation to bone mineral density of hydroxyapatite were compared with those measured at radius distal 1/3 area by Hologic QDR-1000. Obtained results as follows: 1) The conversion equation was Y=5.97X-0.25 and its determination coefficient was 0.9967. The coefficient of variation in the measurement of copper-equivalent value ranged from 4% to 8% and showed high reproducibility. 2) The coefficient of variation in the measurement of bone mineral density by the equation ranged from 7% to 8% and showed high reproducibility. 3) The bone mineral densities ranged from 0.35 to 0.79g/cm2 at mandibular premolararea. 4) The correlation coefficient between bone mineral densities at mandibular premolar area and those at radius distal 1/3 area was 0.8965. As summary, digital image analyzing system using copper-equivalent image and hydroxyapatite phantom appeared to be clinically useful to measure the bone mineral density at dental area.

  • PDF

전자 서베잉을 이용한 서베이드 금관과 국소의치 프레임워크 디자인 (Surveyed restoration and RPD framework design utilizing electronic surveying)

  • 홍용신;박은진;김성균;곽재영;허성주;박지만
    • 대한치과보철학회지
    • /
    • 제49권4호
    • /
    • pp.354-361
    • /
    • 2011
  • 구강 스캐너와 CAD/CAM 기술로 인해 컴퓨터로 제작하는 방식이 활발히 보급된 고정식 보철 증례와는 달리, 의치를 디지털 방식으로 제작하는 데에는 아직 한계가 많다. 촉각을 느낄 수 있는 입력 장비와 전자 서베잉의 개념, 그리고 쾌속 조형법의 적용으로 인해 국소의치를 디지털로 제작할 수 있는 솔루션이 최근 소개되고 있다. 본 증례보고에서는 이러한 국소의치의 디지털 솔루션을 이용하여 총 다섯 명의 환자에서 서베이드 금관 및 국소의치를 제작하였다. 인상 과정상의 문제로 모형과 실제 치아 사이의 형태적 차이가 있었던 경우를 제외하고는 국소의치의 적합도는 우수했으며, 장착 후 안정성과 착탈 시의 유지력 또한 임상에서 적용하는 데에 문제가 없었다.

Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based

  • Graf, Tobias;Guth, Jan-Frederik;Diegritz, Christian;Liebermann, Anja;Schweiger, Josef;Schubert, Oliver
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.351-360
    • /
    • 2021
  • PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 ㎛ in group CF and 34 ± 6 ㎛ in group PC. RMSE of total adjustments was 61 ± 11 ㎛ in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.

Computer-aided design (CAD) 및 쾌속조형술을 이용한 가철성 국소의치 수복 증례 (RPD framework fabrication using computer-aided design (CAD) and rapid prototyping)

  • 박선아;곽재영;허성주;김성균;박지만
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.94-99
    • /
    • 2017
  • CAD/CAM (computer-aided design/computer-aided manufacturing) 기술을 이용한 인레이 및 여러 고정성 보철물의 제작이 보편화되고 구강내 스캐너가 널리 보급되면서 디지털 치의학의 개념이 치과 보철학 분야 전반에 적용되고 있다. 그러나 가철성 보철 부분에서는 디지털 개념의 적용이 쉽지 않으며 기존의 주조 방식에 많이 의존하고 있다. 따라서 가철성 보철물의 제작 과정에 이런 개념을 적용해보려는 시도는 중요한 의미가 있다. 본 증례에서는 하악 Kennedy class III 무치악 환자에서 보철적, 심미적 요구에 의한 교합고경의 증가와 함께 CAD 및 쾌속조형술(RP, rapid prototyping)을 이용한 가철성 국소의치를 제작하였다. CAD를 이용하여 서베잉 및 국소의치 금속 구조물을 설계하였으며, 쾌속조형술은 금속 구조물을 주조하기 위한 레진 패턴 제작에 이용하였다. 9개월 간의 임상적 관찰 기간 동안 만족스러운 심미적, 기능적 결과를 얻어 이를 보고하고자 한다.