• 제목/요약/키워드: digital intraoral scanner

검색결과 95건 처리시간 0.027초

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례 (Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report)

  • 임현정;김명주;권호범;임영준
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.299-306
    • /
    • 2017
  • 본 증례는 완전한 디지털 workflow로 단일 치아 임플란트 지지형 보철물을 즉시 부하하여 수복한 증례이다. 하악 제1대 구치 상실로 내원한 환자로, 구강 스캐너로 구내 디지털 인상채득 후, CT데이터와 디지털 스캔 데이터를 통해 제작한 수술용 가이드를 이용하여 임플란트를 식립하였다. 술 후 1주일 후, 맞춤형 지대주와 임시치아를 체결하여 즉시부하 하였다. 술 후 8주 후 지대주 레벨에서 구강스캐너를 이용하여 디지털 인상채득 후, 술 후 3개월에 지르코니아 최종 보철물을 장착하였다. 본 증례는 환자의 만족도 및 정확성 면에서 만족할 만한 결과를 나타내었으며, 완전한 디지털 과정을 통한 수복 결과 정확성, 심미성, 기능성 면에서 만족할 만한 결과를 나타내었기에 보고하는 바이다.

디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner)

  • 이종원;박지만
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.210-217
    • /
    • 2016
  • 목적: 본 연구의 목적은 실제 환자에서 디지털 구강스캐너로 모형 없이 제작한 보철물의 변연 및 내면 적합도를 평가하는 것이다. 대상 및 방법: 전향적 임상시험으로 시행한 본 예비 연구는 총 11개의 수복물을 대상으로 하였다. 구강스캐너(TRIOS, 3shape, Copenhagen, Denmark)로 디지털 구강인상을 채득한 후, 캐드 디자인 및 밀링 가공 과정을 통해 전부지르코니아 수복물을 제작하였다. 완성된 지르코니아관을 환자 구강 내에 시적하였고, 레플리카 술식으로 보철물-지대치 복제물을 얻었다. 이를 근원심, 협설 방향으로 잘라 변연오차, 변연간극과 축벽부, 선각부, 교합면부의 내면간극을 측정하였다. 통계처리는 Kruskal-Wallis 검정과 Mann-Whitney U 검정을 이용하여 통계적 유의성을 분석하였다(${\alpha}=.05$). 결과: 복제물을 통한 적합도 분석 결과, 근원심, 협설 절편 사이에는 통계적으로 유의한 차이가 없었다(P>.05). 변연간극에 불일치가 있었으며, 변연 오차가 변연간극 보다 컸다(P<.01). 결론: 본 연구의 한계 내에서, 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 적합도는 임상적으로 허용할만한 결과를 보였다. 그러나 지르코니아관의 변연부위가 과풍융되는 경향이 있었으므로 주의 깊은 임상 적용 및 추적 연구가 요구된다.

Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies

  • Louis Hardan;Rim Bourgi;Monika Lukomska-Szymanska;Juan Carlos Hernandez-Cabanillas;Juan Eliezer Zamarripa-Calderon;Gilbert Jorquera;Sinan Ghishan;Carlos Enrique Cuevas-Suarez
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.315-332
    • /
    • 2023
  • PURPOSE. This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS. This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS. The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION. The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.

전신성 피부경화증 환자에서의 3차원 구강스캐너를 이용한 가철성 국소의치 제작 증례 (Fabrication of removable partial denture on scleroderma patient using 3-dimensional intraoral scanner)

  • 김웅규;한중석;윤형인;여인성
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.116-125
    • /
    • 2021
  • 디지털 치의학에서의 주요한 발전 중 하나인 3차원 구강스캐너는 최근 고정성 보철물에 널리 사용되고 있으며 가철성 보철물에서도 사용이 증가하고 있다. 전신성 피부경화증에 의한 안면부 연조직의 경화는 개구량 제한을 일으켜 치아상실을 야기하며 기존의 통상적인 보철 치료를 어렵게 한다. 본 증례에서는 디지털 치의학의 발전을 통한 3차원 구강스캐너를 이용하여 개구량 제한과 그에 따른 소구증을 가진 전신성 피부경화증 환자에서 3차원 구강구조를 광학인상 채득하고, 이를 바탕으로 3D 프린터를 이용한 임시의치 제작을 통해 3차원 구강스캐너를 통한 가철성 보철물 제작의 가능성을 확인하였다. 이후 최종 지대치 정리 후 최종 광학인상 채득하여 국소의치 금속구조물을 제작하였다. 금속구조물의 적합도는 임상적으로 만족스러웠으며 이후 최종 국소의치 제작, 장착하여 상실부위에 대한 수복을 진행, 임상적으로 만족스러운 결과를 얻을 수 있었다.

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans

  • Kontis, Panagiotis;Guth, Jan-Frederik;Schubert, Oliver;Keul, Christine
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.316-326
    • /
    • 2021
  • PURPOSE. Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS. A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS. Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION. Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.

Accuracy of Bite Registration Using Intraoral Scanner Based on Data Trimming Strategy for Fremitus Teeth

  • Jeong, Yuwon;Shim, June-Sung;Kim, Jee-Hwan;Kim, Jong-Eun;Lee, Hyeonjong
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.61-67
    • /
    • 2022
  • Purpose: This study aimed to evaluate the accuracy of bite registration using intraoral scanner based on data trimming strategy for fremitus teeth. Materials and Methods: A reference model was designed by Medit Model Builder software (MEDIT Corp., Seoul). Tooth number 24 and 25 were separated as dies and tooth number 26 was prepared for full-coverage crown. Those were printed using a 3D printer (NextDent 5100). The scanning procedure was performed by a single trained operator with one intraoral scanner (i700; MEDIT Corp.). The scanning groups were divided as follows: group 1 (G1), no fremitus; group 2 (G2), 0.5 mm buccal fremitus in the maxillary left first and second premolar; and group 3 (G3), 1.5 mm buccal fremitus in the maxillary left first and second premolar. Each group was scanned 10 times and were analyzed using the reference model data. Surface-based occlusal clearance was analyzed at the prepared tooth to evaluate accuracy. Result: Mean values of control group (G1) were 1.587±0.021 mm. G2 showed similar values to those from the control group (1.580±0.024 mm before trimming strategy and 1.588±0.052 mm after trimming strategy). G3 showed significantly greater values (1.627±0.025 mm before trimming strategy and 1.590±0.024 mm after trimming strategy) and the differences were found between trimming strategy (P=0.004). Conclusion: Bite trimming strategy for fremitus teeth is a reliable technique to reduce inaccuracies caused by the mobility at maximum intercuspation.

디지털 치열 모형에서 악궁 관계 지표 측정의 타당성 (Validity of Arch Relationship Measurements in Digital Dental Models)

  • 류지인;양병은;이혜림
    • 대한소아치과학회지
    • /
    • 제49권1호
    • /
    • pp.14-24
    • /
    • 2022
  • 이 연구의 목적은 디지털 치열 모형에서 치아 폭경, 볼튼 비율, 수평 피개, 수직 피개를 포함한 교정적 측정의 타당성을 확인하는 것이다. 만 12 - 18세의 환자를 대상으로 세가지 형태의 치열 모형을 획득하였다. 기존의 석고 모형을 형성하였고, DOF freedom HD 모형 스캐너를 통해 디지털 모형으로 변환하였다. 그리고 CS3600 구강 스캐너로 디지털 모형을 형성하였다. 각 모형에서 측정 시행 후, 급내 상관 계수를 통해 계측의 신뢰성과 재현성을 확인하였으며, 대응 표본 t 검정을 사용하여 타당성을 평가하였다. 결과적으로 모든 군에서 급내 상관계수는 0.750을 초과하여 연구자 내 신뢰성과 연구자 간 재현성이 있음을 확인하였다. 모형 스캔한 군은 전체 및 전치 볼튼 비율, 수평 및 수직 피개에서 타당성을 보였다. 구강 스캔한 군은 전치 볼튼 비율, 수평 피개에서 타당성을 보였다. 구강 스캔한 디지털 모형을 이용한 계측은 인상 채득에 어려움이 있는 소아 청소년에게 고려할 수 있는 대안이다. 하지만 임상에서 이를 교정적 분석에 이용할 경우 오차를 고려한 적용이 필요하다.

가상 골격-치열 하이브리드 이미지 생성을 위한 구강 스캐너의 활용 (Intraoral Scan for Virtual Skull-Dentition Hybrid Images of Young Patients)

  • 이주희;양병은;이혜림
    • 대한소아치과학회지
    • /
    • 제49권1호
    • /
    • pp.57-64
    • /
    • 2022
  • 콘빔 전산화 단층촬영(CBCT)은 치열을 왜곡시켜 추가 치열 이미지가 필요하다. 치열 이미지로 주로 사용되는 석고 모형을 대신해 구강 스캐너로 CBCT의 치열 이미지를 보완할 때의 임상적 활용 가능성을 평가하였다. 만 12 - 18세의 20명에게 상악에 대한 석고 모형, 구강 스캔 이미지, CBCT이미지를 획득하였다. 비교를 위해 두 종류의 구강 스캐너를 이용하였는데, 그 중 하나의 구강 스캐너로는 전악을 3분할하여 각각을 스캔한 후 이들을 병합해 전악 이미지를 획득하는 방법을 추가로 시행하였다. 구강 스캐너를 이용해 얻은 가상 골격-치열 하이브리드 이미지를 석고 모형을 통해 얻은 이미지와 중첩하여 각 기준점에서의 좌표 값의 차이와 거리를 측정하였다. 결과적으로 구강 스캐너로 분할하여 스캔하는 방법을 시행했을 때 평균 거리 2 ㎛를 보여 가장 적게 나타났다. 구강 스캐너를 적절히 이용하면 가상 골격-치열 하이브리드 이미지를 위한 치열 이미지로 훌륭히 활용될 수 있을 것이다.

A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction

  • Anh, Ji-won;Park, Ji-Man;Chun, Youn-Sic;Kim, Miae;Kim, Minji
    • 대한치과교정학회지
    • /
    • 제46권1호
    • /
    • pp.3-12
    • /
    • 2016
  • Objective: The purpose of this study was to compare the precision of three-dimensional (3D) images acquired using iTero$^{(R)}$(Align Technology Inc., San Jose, CA, USA) and Trios$^{(R)}$(3Shape Dental Systems, Copenhagen, Denmark) digital intraoral scanners, and to evaluate the effects of the severity of tooth irregularities and scanning sequence on precision. Methods: Dental arch models were fabricated with differing degrees of tooth irregularity and divided into 2 groups based on scanning sequence. To assess their precision, images were superimposed and an optimized superimposition algorithm was employed to measure any 3D deviation. The t-test, paired t-test, and one-way ANOVA were performed (p < 0.05) for statistical analysis. Results: The iTero$^{(R)}$ and Trios$^{(R)}$ systems showed no statistically significant difference in precision among models with differing degrees of tooth irregularity. However, there were statistically significant differences in the precision of the 2 scanners when the starting points of scanning were different. The iTero$^{(R)}$ scanner (mean deviation, $29.84{\pm}12.08{\mu}m$) proved to be less precise than the Trios$^{(R)}$ scanner ($22.17{\pm}4.47{\mu}m$). Conclusions: The precision of 3D images differed according to the degree of tooth irregularity, scanning sequence, and scanner type. However, from a clinical standpoint, both scanners were highly accurate regardless of the degree of tooth irregularity.