• Title/Summary/Keyword: digital elevation map

Search Result 309, Processing Time 0.028 seconds

Refinement of Low Resolution DEM Using Differential Interferometry

  • Kim Chang-Oh;Lee Dong-Cheon;Kim Jeong-Woo;Kim Sang-Wan;Won Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.522-525
    • /
    • 2004
  • Interferometry SAR (InSAR) is a technique to generate topographic map from complex data pairs observed by antennas at different locations. However, to obtain topographic information using InSAR is difficult task because it requires series of complicated process including phase unwrapping and precise recovery of the SAR geometry. Especially, accuracy of the DEM (Digital Elevation Model) produced by repeat pass single SAR pair could be influenced by atmospheric effect. Recently, a new InSAR technique to improve accuracy of DEM has been introduced that utilizes low resolution DEM with a number of SAR image pairs. The coarse DEM plays an important role in reducing phase unwrapping error caused by layover and satellite orbit error. In this study, we implemented DInSAR (Differential InSAR) method which combines low resolution DEMs and ERS tandem pair images. GTOPO30 DEM with 1km resolution, SRTM-3 DEM with 100m resolution, and DEM with 10m resolution derived from 1:25,000 digital vector map were used to investigate feasibility of DInSAR. The accuracy of the DEMs generated both by InSAR and DInSAR was evaluated.

  • PDF

Comparison of Topographical Parameter for DTED and Grid DEM from 1:50,000 Digital Map (DTED와 1:50,000 수치지형도에 의한 격자 DEM의 지형 매개변수 비교)

  • Kim, Yeon-Jun;Shin, Ke-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.5 no.3
    • /
    • pp.19-32
    • /
    • 2002
  • Topographic information is indispensable in the applications that require elevational data. These applications are exemplified by watershed partition, extraction of drainage networks, viewshed analysis, derivation of geomorphologic features, quantification of landslide-terrain, and identification of topographic settings susceptible to landsliding. Therefore, we study the accuracy of data on topographic parameters derived from digital elevation models(DEMs). This research wished to analyze the effect that data source and grid size get in topography parameter using gridded DEM. An analysis of topography parameter extract and compared drainage basin, watershed slope, stream network using DEM is constructed by digital map and DTED DEM. Especially, when extract stream network from gridded DEM, received much effects according to threshold value of flowaccumulation regardless of DEM grid size. Therefore, this study applied equal threshold value of flowaccumulation for two data sources, and compare and analyzed stream network.

  • PDF

Spatial Prediction of Soil Carbon Using Terrain Analysis in a Steep Mountainous Area and the Associated Uncertainties (지형분석을 이용한 산지토양 탄소의 분포 예측과 불확실성)

  • Jeong, Gwanyong
    • Journal of The Geomorphological Association of Korea
    • /
    • v.23 no.3
    • /
    • pp.67-78
    • /
    • 2016
  • Soil carbon(C) is an essential property for characterizing soil quality. Understanding spatial patterns of soil C is particularly limited for mountain areas. This study aims to predict the spatial pattern of soil C using terrain analysis in a steep mountainous area. Specifically, model performances and prediction uncertainties were investigated based on the number of resampling repetitions. Further, important predictors for soil C were also identified. Finally, the spatial distribution of uncertainty was analyzed. A total of 91 soil samples were collected via conditioned latin hypercube sampling and a digital soil C map was developed using support vector regression which is one of the powerful machine learning methods. Results showed that there were no distinct differences of model performances depending on the number of repetitions except for 10-fold cross validation. For soil C, elevation and surface curvature were selected as important predictors by recursive feature elimination. Soil C showed higher values in higher elevation and concave slopes. The spatial pattern of soil C might possibly reflect lateral movement of water and materials along the surface configuration of the study area. The higher values of uncertainty in higher elevation and concave slopes might be related to geomorphological characteristics of the research area and the sampling design. This study is believed to provide a better understanding of the relationship between geomorphology and soil C in the mountainous ecosystem.

A Study on Interpolation methods and size of grid to the various topographical characteristics for the construction of DEM(Digital Elevation Model) (수치표고모형(DEM) 구축을 위한 지형별 보간 방법 및 격자크기에 관한 연구)

  • Woo, Je-Yoon;Koo, Jee-Hee;Hong, Chang-Hee;Kim, Tae-Hoon
    • Journal of Korea Spatial Information System Society
    • /
    • v.3 no.2 s.6
    • /
    • pp.5-19
    • /
    • 2001
  • We are able to construct and utilize DEM(Digital Elevation Model) throughout the NGIS(National Geographic Information System) project. It is important that interpolation methods and appreciate size of grid for the construction of accurate DEM(Digital Elevation Model). There were several references related to the DEM(Digital Elevation Model) construction method, however they couldn't consider various topographical characteristics in the korea. In this study, we recommended that suitable interpolation method for each topographic element. After dividing Poonggi area into mountain, hill, urban, agricultural land, we constructed DEM(Digital Elevation Model) with various interpolation methods and grid size using 1:5,000 digital map. Then evaluated accuracy using elevation data which extracted from air-photo. The interpolation methods were analyzed and compared for various topographical conditions. As a result, Kriging method was superior to TIN method for all the topographical conditions. Another experiment was performed to examine optimal grid space for DEM with each topographical condition. 10m grid space was most suitable for mountain area and hilly districts, while 30m grid space was most suitable for urban area and farm land.

  • PDF

Extraction of Ground Control Point (GCP) from SAR Image

  • Hong, S.H.;Lee, S.K.;Won, J.S.;Jung, H.S.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1058-1060
    • /
    • 2003
  • A ground control point (GCP) is a point on the surface of Earth where image coord inates and map coordinates can be identified. The GCP is useful for the geometric correction of systematic and unsystematic errors usually contained in a remotely sensed data. Especially in case of synthetic aperture radar (SAR) data, it has serious geometric distortions caused by inherent side looking geometry. In addition, SAR images are usually severely corrupted by speckle noises so that it is difficult to identify ground control points. We developed a ground point extraction algorithm that has an improved capability. An application of radargrammetry to Daejon area in Korea was studied to acquire the geometric information. For the ground control point extraction algorithm, an ERS SAR data with precise Delft orbit information and rough digital elevation model (DEM) were used. We analyze the accuracy of the results from our algorithm by using digital map and GPS survey data.

  • PDF

A Feasibility Study for Mapping Using The KOMPSAT-2 Stereo Imagery (아리랑위성 2호 입체영상을 이용한 지도제작 가능성 연구)

  • Lee, Kwang-Jae;Kim, Youn-Soo;Seo, Hyun-Duck
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.1
    • /
    • pp.197-210
    • /
    • 2012
  • The KOrea Multi-Purpose SATellite(KOMPSAT)-2 has a capability to provide a cross-track stereo imagery using two different orbits for generating various spatial information. However, in order to fully realize the potential of the KOMPSAT-2 stereo imagery in terms of mapping, various tests are necessary. The purpose of this study is to evaluate the possibility of mapping using the KOMPSAT-2 stereo imagery. For this, digital plotting was conducted based on the stereoscopic images. Also the Digital Elevation Model(DEM) and an ortho-image were generated using digital plotting results. An accuracy of digital plotting, DEM, and ortho-image were evaluated by comparing with the existing data. Consequently, we found that horizontal and vertical error of the modeling results based on the Rational Polynomial Coefficient(RPC) was less than 1.5 meters compared with the Global Positioning System(GPS) survey results. The maximum difference of vertical direction between the plotted results in this study and the existing digital map on the scale of 1/5,000 was more than 5 meters according as the topographical characteristics. Although there were some irregular parallax on the images, we realized that it was possible to interpret and plot at least seventy percent of the layer which was required the digital map on the scale of 1/5,000. Also an accuracy of DEM, which was generated based on the digital plotting, was compared with the existing LiDAR DEM. We found that the ortho-images, which were generated using the extracted DEM in this study, sufficiently satisfied with the requirement of the geometric accuracy for an ortho-image map on the scale of 1/5,000.

A Method of Site Selection for the Artificial Recharge of Groundwater Using Geospatial Data (지형공간자료를 이용한 지하수 인공함양 적지 선정 방안)

  • Lee, Jae One;Seo, Minho;Han, Chan
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.5
    • /
    • pp.427-436
    • /
    • 2015
  • This study aims to select an optimal site for the development of small-scaled artificial ground water recharge system with the purpose of 50ton/day pumping in dry season. First of all, the topography shape satisfying the numerous factors of a hydraulic model experiment is defined and an appropriate pumping efficiency is calculated through the model experiment of injection and pumping scenario. In next step, GIS(Geographic Information System) database are constructed by processing several geospatial data to explore the optimal site. In detail, watershed images are generated from DEM(Digital Elevation Model) with 5m cell size, which is set for the minimum area of the optimal site selection. Slope maps are made from DEM to determine the optimal hydraulic gradient to procure the proper aquifer undercurrent period. Finally, the suitable site for artificial recharge system is selected using an integration of overall data, such as an alluvial map, DEM, orthoimages, slope map, and watershed images.

Mapping of Inundation Vulnerability Using Geomorphic Characteristics of Flood-damaged Farmlands - A Case Study of Jinju City - (침수피해 정보를 이용한 농경지의 지형학적 침수취약지도 작성 - 진주시를 사례로 -)

  • Kim, Soo-Jin;Suh, Kyo;Kim, Sang-Min;Lee, Kyung-Do;Jang, Min-Won
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.3
    • /
    • pp.51-59
    • /
    • 2013
  • The objective of this study was to make a map of farmland vulnerability to flood inundation based on morphologic characteristics from the flood-damaged areas. Vulnerability mapping based on the records of flood damages has been conducted in four successive steps; data preparation and preprocessing, identification of morphologic criteria, calculation of inundation vulnerability index using a fuzzy membership function, and evaluation of inundation vulnerability. At the first step, three primary digital data at 30-m resolution were produced as follows: digital elevation model, hill slopes map, and distance from water body map. Secondly zonal statistics were conducted from such three raster data to identify geomorphic features in common. Thirdly inundation vulnerability index was defined as the value of 0 to 1 by applying a fuzzy linear membership function to the accumulation of raster data reclassified as 1 for cells satisfying each geomorphic condition. Lastly inundation vulnerability was suggested to be divided into five stages by 0.25 interval i.e. extremely vulnerable, highly vulnerable, normally vulnerable, less vulnerable, and resilient. For a case study of the Jinju, farmlands of $138.6km^2$, about 18% of the whole area of Jinju, were classified as vulnerable to inundation, and about $6.6km^2$ of farmlands with elevation of below 19 m at sea water level, slope of below 3.5 degrees, and within 115 m distance from water body were exposed to extremely vulnerable to inundation. Comparatively Geumsan-myeon and Sabong-myeon were revealed as the most vulnerable to farmland inundation in the Jinju.

A Study on the Terrain Analysis using TIN & GRID-Based Digital Terrain Model (TIN과 GRID기반의 수치지형모델을 이용한 지형분석에 관한 연구)

  • 윤철규
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.67-74
    • /
    • 1998
  • This paper performed terrain analysis using DTM(digital terrain model) with TIN/ GRID structure on PC environment. Contour layer from 1:5,000 scale map was used to produce DTM. DTHs were produced with and without considering breakline for each data structure. Processing time, file size, mean elevation and standard variation were analyzed for each DTM. slope map, aspect map were analyzed for grid structure with consideration of TEX>$5\times{5m},\;l0\times{10m},\;15\times{15m},\;l0\times{30m},\;45\times{45m},\;60\times{60m}$ cell size respectively. The results suggest following; The incorporation of breakline does improve mapping accuracy for highly disturbed landscape, Mean elevation doesn't increase as the grid size increases, while processing time, storage room is significantly lessened. Thus, the optimal grid size must be determined in advance for efficient application. slope decreases, while aspect increases as grid size is increasing.

  • PDF

A Process of Optimization for the Best Orientation of Building Façades Based on the Genetic Algorithm by Utilizing Digital Topographic Map Data (수치지형도 데이터를 활용한 유전자 알고리즘 기반 건축외피의 최적향 산정 프로세스)

  • Choe, Seung-Ju;Han, Seung-Hoon
    • Land and Housing Review
    • /
    • v.13 no.1
    • /
    • pp.113-129
    • /
    • 2022
  • A building's eco-friendliness is directly related to various values including the life cycle cost of a building. However, the conventional architectural design method has a limitation in that it cannot create an optimized case according to the surrounding environmental conditions. Therefore, the purpose of this research is to present a design assistance tool that can review planning cases optimized for the environmental conditions of the building site in the planning stage of architectural production. To achieve the purpose of the study, an algorithm for realizing 3D modeling of the region and analysis of the solar environment was produced based on the site contours, building, and road information from the digital topographic map provided by the National Geographic Information Institute. To examine the validity of the developed algorithm, a comparative experiment was conducted targeting the elevation direction of the existing building. As a result, it was found that the optimal elevation direction selected by the algorithm can receive higher insolation compared to the front facade of the main building.