Automatic Anatomically Adaptive Image Enhancement in Digital Chest Radiography

  • Kim, Sung-Hyun;Lee, Hyoung-Koo;Ho, Dong-Su;Kim, Do-Il;Choe, Bo-Young;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.442-445
    • /
    • 2002
  • We present an algorithm for automatic anatomically adaptive image enhancement of digital chest radiographs. Chest images were exposed using digital radiography system with a 0.143 mm pixel pitch, l4-bit gray levels, and 3121 ${\times}$ 3121 matrix size. A chest radiograph was automatically divided into two classes (lung field and mediastinum) by using a maximum likelihood method. Each pixel in an image was processed using fuzzy domain transformation and enhancement of both the dynamic range and local gray level variations. The lung fields were enhanced appropriately to visualize effectively vascular tissue, the bronchus, and lung tissue, etc as well as pneumothorax and other lung diseases at the same time with the desired mediastinum enhancement. A prototype implementation of the algorithm is undergoing trials in the clinical routine of radiology department of major Korean hospital.

  • PDF

비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징 (Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 정회원;김정민;정만희;임은경
    • 대한디지털의료영상학회논문지
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택 (The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 김정민;임은경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.273-277
    • /
    • 2005
  • 디지털 의료 영상의 빠른 발전은 새로운 기술-비정질 평판형 측정기-에 대한 최적의 기술이 동행되지 못했다. 이번 실험으로 비정질 평판형 측정기를 사용한 흉부 방사선 영상의 대한 환자선량과 영상의 화질에 대하여 비교하였다. 모든 실험은 비정질 평판형 측정기를 사용하였다. 흉부 팬텀을 사용한 흉부 방사선영상은 관전압 $60{\sim}150\;kVp$에서 획득하였다. 이번 실험을 통하여 획득된 비정질 평판형 측정기를 사용한 X-선 에너지에 대한 영상의 질과 환자선량에 관련된 정보들을 보고한다. 이 정보는 비정질 평판형 측정기를 사용한 시스템에서 최적의 관전압의 선정에 효과적인 정보를 제공하며, 특히 일반적인 흉부 검사에 적용될 수 있을 것이다.

  • PDF

메디안 필터를 이용한 영상의 경계 검출 (Edge Detetetion of the Image using Median Filter)

  • 이상훈;김승환;김경식;강준길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1409-1412
    • /
    • 1987
  • Median filter techniques were applied to the chest radiographs for the digital image processing. Histogram distributions were transformed to convert the gray level for detections of the small gray deviations of the image boundaries.

  • PDF

Automatic detection of the lung orientation in digital PA chest radiographs

  • Nahm, Kie-B.
    • Journal of the Optical Society of Korea
    • /
    • 제1권1호
    • /
    • pp.60-64
    • /
    • 1997
  • An image processing algorithm is presented that can identify the orientation as well as the left/right side (parity) of the digitized radiographs. The orientation was found by computing the mean square deviation between the sampled gray values along the center and their best-fit linear regression relations. The parity was determined by comparing the area difference between two thresholded images of the left and the right side around the heart, which is assumed to be around the center of the image. This method was tested with 86 images with their orientations intentionally rotated. The rotation was limited to multiples of 90 degrees, as this was the way the rotation is most likely to happen in the clinical environment. We obtained positive responses for 85 out of 86 images subject to the screening.

시각특성을 고려한 디지털 흉부 X-선 영상의 적응적 향상기법 (Adaptive image enhancement technique considering visual perception property in digital chest radiography)

  • 김종효;이충웅;민병구;한만청
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.160-171
    • /
    • 1994
  • The wide dynamic range and severely attenuated contrast in mediastinal area appearing in typical chest radiographs have often caused difficulties in effective visualization and diagnosis of lung diseases. This paper proposes a new adaptive image enhancement technique which potentially solves this problem and there by improves observer performance through image processing. In the proposed method image processing is applied to the chest radiograph with different processing parameters for the lung field and mediastinum adaptively since there are much differences in anatomical and imaging properties between these two regions. To achieve this the chest radiograph is divided into the lung and mediastinum by gray level thresholding using the cumulative histogram and the dynamic range compression and local contrast enhancement are carried out selectively in the mediastinal region. Thereafter a gray scale transformation is performed considering the JND(just noticeable difference) characteristic for effective image displa. The processed images showed apparenty improved contrast in mediastinum and maintained moderate brightness in the lung field. No artifact could be observed. In the visibility evaluation experiment with 5 radiologists the processed images with better visibility was observed for the 5 important anatomical structures in the thorax.

  • PDF

The reduction methods of operator's radiation dose for portable dental X-ray machines

  • Cho, Jeong-Yeon;Han, Won-Jeong
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.160-164
    • /
    • 2012
  • Objectives: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. Conclusions: When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교 (Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices)

  • 김상지;용환석;강은영;양제파;김정윤;윤영훈
    • 대한영상의학회지
    • /
    • 제85권1호
    • /
    • pp.138-146
    • /
    • 2024
  • 목적 카메라형 휴대형 X선 장치를 이용하여 촬영한 흉부 X선 사진의 영상품질을 기존 이동형 디지털 X선 장치로 촬영한 영상과 비교하여 임상에서 사용 가능한지 평가하고자 하였다. 대상과 방법 2020년 9월부터 2021년 5월까지 응급실에 내원한 환자 중 기관내 삽관, 중심정맥관, 비위관 등을 삽입한 86명의 환자를 대상으로 하였다. 환자들은 기구 삽입 전 기존 이동형 디지털 X선 장치, 기구 삽입 후 카메라형 휴대형 X선 장치를 이용하여 각각 흉부 영상을 촬영하였다. 두 명의 영상의학과 의사가 얻어진 두 영상을 삽입기구의 식별에 대하여 5점 척도, 전반적인 영상 품질에 대하여 20점 만점으로 평가하였다. 결과 카메라형 휴대형 X선 장치로 삽입한 기구의 식별에 대한 평가는 4.67 ± 0.71점이었다. 전반적인 영상품질에 대한 평가는 기존 이동형 디지털 X선 장치와 카메라형 휴대형 X선 장치가 각각 19.70 ± 0.72점과 15.02 ± 3.31점(p < 0.001)이었고, 호흡 및 움직임 관련 인공물, 기관 및 기관지, 폐혈관, 심장 뒤 혈관, 흉추 추간판 공간, 횡격막 하 혈관, 횡격막 관찰의 세부항목에서 카메라형 X선 장치의 점수가 통계적으로 유의하게 점수가 낮았다(횡격막 관찰 세부항목 p = 0.013, 그 외 세부항목 p < 0.001). 결론 카메라형 휴대형 X선 장치는 흉부X선 사진에서 삽입 기구의 평가를 목적으로 사용하는 것은 가능하나 영상의 품질 저하가 있으므로 일반적인 진단 목적의 사용에는 주의를 요한다.

디지털 방사선 흉부영상의 영상개선과 임상평가 (Image Enhancement and Clinical Evaluation in Digital Chest Radiography)

  • 김성현;서태석;최보영;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제19권3호
    • /
    • pp.143-149
    • /
    • 2008
  • 본 연구의 목적은 디지털 방사선 흉부영상의 개선을 위한 영상처리방법을 제안하고 임상적 유용성을 평가하는 것이다. 흉부영상의 edge를 보존하면서 산란성 노이즈 제거를 위한 비선형의 반복 필터가 고안되었다. 영상의 다이나믹 레인지 (dynamic_range)의 조절이 이루어 졌으며, 해부학적 영역과 주변픽셀과의 호환성을 바탕으로 적응적 영상증강이 이루어졌다. 종격동 영역에서의 영상증강과 더불어, 폐 영역에서의 혈관조직, 기관지, 폐 조직 등이 적절하게 증강되었다. 3명의 판독의에 의한 임상평가가 이루어 졌으며, PA 영상에서는 11개, 그리고 Lateral 영상에서는 9개의 해부학적 영역이 면밀하게 관찰되었다. 각각 100장의 영상들이 ITU (International Telecommunication Union) recommendation 500에 따라 평가되어졌으며, 그 결과는 good과 adequate중간인 3.4의 평균치를 보였다. 이는 제안한 영상처리의 임상적 유용성이 최소한 양호함 이상의 가치가 있음을 의미한다. 유용한 해부학적 정보의 손실을 방지하기 위해, 영상표시장치와 인간의 인지계를 고려하면서 영상개선이 이루어졌다. 디지털 방사선기기의 등장으로 진단의 정확성을 향상시키기 위한 지속적인 영상 개선연구가 필요하다.

  • PDF

디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로 (Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation)

  • 진성진;임인철;조지환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.1-6
    • /
    • 2017
  • 흉부방사선 영상의 평가는 시각에 의한 사진평가가 가장 실용적이고 효과적인 방법으로 알려져 있다. 미국 방사선 안전국 규정 평가표(Bureau of Radiological Health, BRH)는 흉부방사선 영상의 해부학적 평가와 물리적 평가를 합하여 평가하는 효율적인 영상 평가방법이다. 본 연구는 여성 351명의 흉부방사선 영상을 체질량지수(Body Mass Index, BMI)와 허리둘레, 관전류량(mAs)과의 관계를 비교하고, 미국 방사선 안전국 규정 평가표를 사용하여 흉부 방사선 영상품질평가를 시행하였다. 대상자의 평균 연령은 $30.17{\pm}4.73$세이고, 허리둘레는 평균 $66.91{\pm}4.67cm$이었다. 체질량지수 값의 평균은 $20.21{\pm}2.23$으로 나타났으며, 전체 대상자의 관전류량 평균값은 $3.04{\pm}0.78$이고, 미국 방사선 안전국 규정 평균값은 $79.83{\pm}8.45$이었다. 허리둘레가 커질수록 관전류량 값이 증가함으로 나타났으며, 체질량지수가 커질수록 mAs값도 증가하였다. 연구대상자의 허리둘레, 관전류량, 미국 방사선 안전국 규정 값은 체질량지수 값이 커지면 허리둘레와 관전류량 평균값이 증가하였고, 미국 방사선 안전국 규정 값은 체질량지수가 높은 그룹이 낮은 그룹에 비하여 상대적으로 낮게 나타났으며, 통계적으로 유의하였다. 흉부검사 시 피검자의 신체두께나 체질량지수에 따라 자동노출제어 장치의 노출제어가 적절히 잘 이루어진 것으로 생각되며, 체질량지수가 증가할수록 신체두께가 커지고 또한 여성의 유방 두께도 증가하여 자동노출제어 장치에 의한 노출량이 변화되어 영상품질에 영향을 미치는 것으로 생각되어진다.