Measurement of Finger Blood Flow in Raynaud's Phenomenon by Radionuclide Angiography (레이노드 현상에서 수지혈류 측정에 관한 연구)

  • Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul;Choi, Sung-Jae;Koh, Chang-Soon;Kim, Sang-Joon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.183-190
    • /
    • 1987
  • In Raynaud's phenomenon, the authors measured finger blood flow after ice water exposure by analyzing the time activity curve of radionuclide angiography on both hands. The results were as follows: 1) The digital blood flow did not decrease after ice water exposure in normal subjects. 2) In the patients with Raynaud's phenomenon, there were two groups: the one had decreased digital blood flow after cold exposure, and the other had paradoxically increased digital blood flow after cold exposure. 3) There was no difference in the digital blood flow of hand in room temperature between the normal and the patients with reduced digital blood flow after cold exposure, but the digital blood flow of the hand in room temperature was markedly reduced in the patients with paradoxically increased flow after cold exposure. 4) In the static image the difference was not significant in comparision with the dynamic study, because it represents pooling of the blood in the vein rather than flow. 5) After the treatment with nifedipine, the digital blood flow increased. In conclusion, the radionuclide angiography was useful in measuring the digital blood flow in Raynaud's phenomenon, and further studies with various drugs is expected.

  • PDF

Comparison of normal and replantation digital blood flow using photo-plethysmography (Photo-Plethysmography를 이용한 정상과 재접합 수지 혈류량의 비교)

  • Nam, Ki-Chang;Kim, Sung-Woo;Rah, Dong-Kyun;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.322-324
    • /
    • 2004
  • Up to the present, digital replantation patients has appealed different symptoms due to blood circulatory failure. But, the level of blood circulatory failure has been evaluated only by clinical symptoms, or angiography. According to the cases of digit replantation is increasing, then objective evaluation methods of the level of blood circulation failure is needed other than patient's subjective symptoms and complaints. Although angiography, doppler, electromagnetic flowmeter, laser blood flowmeter, mechanical blood flowmeter has been used for the evaluation of the blood circulatory failure, the result was affected by time, place, surrounding temperature, patient's body temperature, and even emotion. Therefore, it is pointed out with lack of availability, feasibility and reproducibility. Thus, we compared digital blood flow of dominant hand to non dominant hand, and replanted fingers to opposite normal fingers from developed photo-plethysmography. The average digital blood flow showed no difference in normal digits each other, but, replanted digits showed average of 53% (9 - 100 %) compare to opposit normal digits. As it measure relative blood flow for circulatory failure of tissue such as fingers and toes more sensitively, reliably. In conclusion, it is expected that photo- plethysmography will be very useful for diagnosis, curative effect, prognosis of blood circulatory failure in digital replantation patient.

  • PDF

Development of Impedance Plethysmography and Measurement of Digital blood Flow (임피던스 혈량측정법을 이용한 손가락 혈류량의 측정)

  • Kim, Deok-Won;Song, Chul-Gyu;Kim, Won-Ky;Lee, Myong-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.71-73
    • /
    • 1991
  • In this study electrical impedance plethysmograph was developed and each ten digital blood flow was measured for eight normal males and a patint with digital arterial reconstruction surgery. Blood flow of the digit with surgery was approximately fourty percent compared to that of the other normal digit. For the normal subjects, right-handed subjects generally have larger blood flow in right fingers than that in left fingers while it was reverse for the left-handed subjects. The relative average magnitude of the digital blood flow is the third, first, second, fourth, and fifth digit in descending order for the left and right hand, respectively. Blood flow of the fifth digit for all subjects except one was the smallest among the five digits.

  • PDF

Development of Impedance Plethysmograph and Measurement of Digital Blood Flow (임피던스 혈류량측정기의 개발 및 손가락 혈류량의 측정)

  • 김덕원;송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • In this study electrical impedance plethysmograph was developed and each ten digital blood flow was measured for eight nomal males and a patient tvith digital arterial reconstruction surgery. Blood flow of the digit with surgery was approximately fourty percent compared to that of the other normal digit. For the normal subjects, right - handed subjects generally have larger blood flow in right fingers than that in left fingers while it was reverse for the left - handed subjects. The relative average magnitude of the digltal blood flow Is the third, first, second, fourth, and fifth digit in descending order for the left and rich hand, respectively. Blood flow of the fifth digit for all subjec!s except one was the smallest among the five digits.

  • PDF

A study on the measurement of Blood flow-turbulence (혈류의 Flow-Turbulence 측정에 관한 연구)

  • Ko, Yeon-Soon;Kang, Chung-Shin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.294-296
    • /
    • 1988
  • The tomographic imaging that employs ultrasonic echos has achieved outstanding advances in recent years, and today, ultrasonic diagnostic equipment has become the tool that is absolutely indispensible for clinical operations. Meanwhile, the feasility of measuring blood flow in the heart and vessels by the use of Doppler effect in ultrasonic waves is a well known fact. With respect to the method of blood flow measurment, there are two kinds which employ continous wave and pulse wave doppler system. In this paper, we describe the measurment of Blood flow-turbulence using general purpose Digital Signal Processing Board which had been implemented for the purpose of real-time spectrum analyser. Blood flow-turbulence means the blood-flow behavior. And it's value proportional to the spectrum variance. Therefore mean frequency of blood signal and variance provide useful diagnostic information. We have applied to the major arteries and vein, obtained the information about the time dependent blood-flow behavior.

  • PDF

Changes of Facial Temperature and Blood Flow Rates by Treatment of Miso Facial Rejuvenation Acupuncture (미소안면침이 안면 피부 온도와 혈류량에 미치는 영향)

  • Kim, Tae Yeon;Bak, Jong Phil;Kim, Yong Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.481-486
    • /
    • 2013
  • To investigate the effects of facial temperature and blood flow rates generated by Miso Facial Rejuvenation Acupuncture treatment. Ten women in their twenties to fifties with no skin diseases were recruited. Miso Facial Rejuvenation Acupuncture(MFRA) was performed on the both sides of their face. We measured their facial temperature using Digital Infrared Thermal Imaging(DITI) and blood flow rates using Laser Doppler Perfusion Imaging(LDPI) at pre-treatment, immediately, twenty and sixty minutes after treatment. We analyzed data using student's t-test(p<0.05). After MFRA treatment, facial temperature on the measurement area increased immediately from $30.5{\pm}1.0^{\circ}C$ to $31.5{\pm}1.0^{\circ}C$, a statistically significant increase. Sixty minutes after treatment, facial temperature on the measurement area decreased a little bit($30.2{\pm}0.6^{\circ}C$), but there was no statistical significance. After MFRA treatment, facial blood flow rates on the measurement area increased immediately from $165.1{\pm}52.3$ PU to $342.7{\pm}51.3$ PU, a statistically significant increase. Sixty minutes after treatment, facial blood flow rates measurement area were recovered almost at the same level as before treatment. MFRA treatment could increase facial temperature and blood flow rates.

Design and Evaluation of Blood flow Measurement Using Self-mixing type Semiconductor Laser (자기혼합형 반도체 레이저를 이용한 혈류측정 시스템 설계 및 평가)

  • Kim, Duck-Young;Lee, Jin;Kim, Se-Dong;Ko, Han-Woo;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.499-506
    • /
    • 1996
  • Blood flow velocimeter is an essential device to measure the blood flow in skin tissue. In this study, we developed a high-speed LDV(laser Doppler Velocimeter) that has real time processing capability using a DSP(digital signal processing) chip and is able to continuously measure information about blood-flow based on a noninvasive method using self-mixing type laser diode. This LDV system has a simpler structure than any other typical blood flow velocimeter and is composed of new self-mixing probe, stabilizer circuits DSP board, and interf'ace boule We measured velocity of speaker-unit by operational frequencies to identify Doppler effect of this system, performed clinical experiment on bare finger tip and compared it with a commercial euipment BPM403A(USA).

  • PDF

Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging (체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰)

  • Lee, Hyun-Sook
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.180-184
    • /
    • 2011
  • The changes in the blood flow in the peripheral vascular system under strong pulsed magnetic fields (pMF) were studied by digital infrared thermal imaging (DITI). After pMF stimulus temperatures in stimulated area were commonly increased in both groups of age and gender. In order to reduce heat generated from coil in pMF stimulus system plastic moldings were fabricated, so that certain distance was kept between stimulus system and the skin and to prevent direct contact to the skin. It is believed that skin temperature is increased by internal electromagnetic energy stimulated the peripheral vascular system by non-contact method.

Peripheral Periarterial Sympathectomy for the Treatment of Raynaud's Phenomenon(Case Report) (말초 동맥 교감 신경 절제술을 이용한 레이노드 현상의 치료(증례 보고))

  • Lee, Kwang-Suk;Park, Jong-Woong;Suh, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.111-116
    • /
    • 1997
  • The treatment of chronic digital pain and cold intolerance due to Raynaud's phenomenon is quite difficult especially it is combined with scleroderma. Several surgical trial such as cervicothoracic sympathectomy have been attempted for the medically unresponsible Raynaud's phenomenon, but their results were unsatisfactory. We have tried peripheral periarterial sympathectomy for the 44 years old female patient who had medically unresponsible severe Raynaud's phenomenon with scleroderma. Periarterial adventitial stripping was performed at the level of wrist, superficial palmar arch, common digital artery and proper digital artery about 1.5-2 cm in length. Preoperative angiography and radioactive angiography were done and preoperatively and postoperatively the blood flow was measured by the desk top computer-aided histogram. Both hands digital pain were markedly reduced after operation and blood flow increased as compaired with the preoperative measure.

  • PDF