• Title/Summary/Keyword: digital X-ray imaging

Search Result 225, Processing Time 0.024 seconds

Analysis of Original and Processing Image by Control of Exposure Dose, kVp in Digital Radiography (디지털 방사선에서 조사선량과 관전압조절에 의한 원본영상과 처리영상 분석)

  • Kim, Bo-Ra;Ryu, Sin-Young;Seok, Jin-Young;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Dynamic range on the digital detector can be a representation to the ratio of maximum and minimum of pixel value. Wide dynamic range and post processing ability of the digital detector made difficult to recognize visually to high or low dose images. We were evaluated a change of mean pixel value on the original and processed image, when we controlled the kVp, mA, exposure time on the digital detector. On the kVp of a constant condition, we were acquired an original and processed image by changes of mA, exposure time. According to the thickness of the subject under the same conditions, to determine a relation of pixel value and X-ray intensity, we used an aluminum step wedge. When mA and exposure times were changed under the kVp of a constant condition, the X-ray intensity was decreased by the reduction of the mean pixel value. In addition when kVp was increased in a constant condition of mAs, the mean pixel value was increased according to the increment of the X-ray intensity. Therefore, low kVp, high mA and short exposure time were a way to reduce a patient dose.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF

Implementation of a Full Field Digital Mammography (디지털 유방X-선촬영기의 구현)

  • Roh, Young-Sup;Yeo, Se-Yeon;Lee, Jae-Jun;Sohn, Surg-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4578-4589
    • /
    • 2011
  • The technologies of image acquisition, display, and storage of the breast have been developed in their specialized fields in recent years. The image acquisition system is a device that absorbs and stores images after examining breast tissue using X-ray. Due to the specificity and sensitivity of imaging, the early detection of breast cancer is feasible. In this paper, the current technologies for digital mammography are reviewed, and we propose a digital mammography and evaluate the performance of the implemented system.

A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography (산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.345-353
    • /
    • 2021
  • Digital radiography imaging systems can also help diagnose lesions in patients, but if x-rays that enter the human body cause scatter x-ray due to interaction with substances, they affect the signal and noise characteristics of digital x-ray images. To regard the human body as polymethyl methacrylate (PMMA) and observe the properties of scattered x-ray generated from PMMA on x-ray images, we analyze signal and noise in the spatial domain as well as noise-power spectrum (NPS), and detective quantum efficiency (DQE) at zero frequency. As PMMA thickness increased, signals decreased, the noise increased, and NPS degradation was identified in overall spatial frequencies. Based on these characteristics, zero-frequency performance was also shown to be degraded. Comparative analysis with Monte-carlo simulations will need to be made to analyze the zero-frequency performance by scattered x-ray of indirect conversion-type x-ray detectors more quantitatively.

A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT (X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구)

  • Jin, Seung-Oh;Heo, Chang-Won;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF

A grid-line suppression technique based on the nonsubsampled contourlet transform in digital radiography

  • Namwoo Kim;Taeyoung Um;Hyun Tae Leem;Bon Tack Koo;Kyuseok Kim;Kyu Bom Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.655-668
    • /
    • 2023
  • In radiography, an antiscatter grid is a well-known device for eliminating unexpected x-ray scatter. We investigate a new stationary grid artifact suppression method based on a nonsubsampled contourlet transform (NSCT) incorporated with Gaussian band-pass filtering. The proposed method has an advantage that extracts the Moiré components while minimizing the loss of image information and apply the prior information of Moiré component positions in multi-decomposition sub-band images. We implemented the proposed algorithm and performed a simulation and an experiment to demonstrate its viability. We did this experiment using an x-ray tube (M-113T, Varian, focal spot size: 0.1 mm), a flat-panel detector (ROSE-M Sensor, Aspenstate, pixel dimension: 3032 × 3800 pixels, pixel size: 0.076 mm), and carbon graphite-interspaced grids (JPI Healthcare, 18 cm × 24 cm, line density: 103 LP/inch and 150 LP/inch, ratio: 5:1, focal distance: 65 cm). Our results indicate that the proposed method successfully suppressed grid artifacts by reducing them without either reducing the spatial resolution or causing negative side effects. Consequently, we anticipate that the proposed method can improve image acquisition in a stationary grid x-ray system as well as in extended x-ray imaging.

Development of Data Acquisition System using the Backscattered X-ray (후방산란성 엑스레이를 이용한 데이터 획득 시스템 개발)

  • Hwang, In-Ho;Jung, Jin-Seok;Yuk, Sun-Woo;Yoo, Sun-Kook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.129-133
    • /
    • 2009
  • Considerable attention has been focused on digital X-ray systems with transmission. However, only a few attempts have been made using X-ray backscatter systems. This study developed a Data Acquisition System (DAS) for backscattered X-rays. The imaging system used X-ray backscatter at low energy levels, which has unique advantages in terms of acquiring information that cannot be obtained using the transmission system. Such systems are of potential benefit in the medical, industrial, security and military fields because of its practical benefits and the low doses used. The developed system is a similar body scan system. Experiments were carried out using a several metal materials and a fish, which produces results similar to those obtained using the human body during X-ray testing.

RNSXI(real-name shooting X-ray of inspector) Settlement Realization applying PACS Database, In Digital Medical environment (PACS Database를 활용한 촬영실명제 정착화 실현)

  • Kang, Ji-Youn;Lee, Lae-Gon;Kang, Doo-Hee;Lee, Hwa-Sun;Hwang, Sun-Gwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.5-9
    • /
    • 2007
  • As developing the medical treatment image portion with the change of these times, PACS, which is able to digitalize image portion data, has a lot of data-based image data. Applying this PACS, we would like to settle down RNSXI(real-name shooting X -ray of inspector) system. We interviewed with P ACS's operators of university hospitals which is using PACS in Seoul about the present conditions whether using of RNSXI or not. And we inquired the RNSXI equipments, applying PACS database, and Interface conditions undertook to do in our hospital. All university hospitals in Seoul are set up the P ACS system. But no hospital use the RNSXI. In our hospital, we can check inspector' name or initials who exposure x-ray with the PACS Viewer by looking over equipments(CR, DR, US, MG, MR, CT) and Interface of the DICOM Header data. However, some equipments like RF and Angio can not check inspector' name or initials. Under the Film/System environment, RNSXI system has been used frequently like that inspector's signature or initial added to a patient data. Though the digital medical treatment was developed, RNSXI system was declined. It is necessary to using RNSXI system in order to improving radiologists' rights, even if it is not under the application of the medical treatment image laws. If RNSXI system use, radiologists should specialize in their major and the Repeat rate should be reduced. In environment of PACS, RNSXI system can be used by linking both the equipments and the Interface with a production enterprise of P ACS. Therefore RNSXI system applying the P ACS datebase should settle down in our medical system for being provided lots of data.

  • PDF

COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM (직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구)

  • Do Jung-Joo;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF