• 제목/요약/키워드: digital $(k_0,\

검색결과 3,233건 처리시간 0.03초

요통치료에서 승마요법의 영향 (The Influence of Therapeutic Horseback Riding on Treatment of Low Back Pain)

  • 장상철;이기승;김인창;김진희;정명수
    • 대한한의정보학회지
    • /
    • 제21권1호
    • /
    • pp.23-34
    • /
    • 2015
  • This study is aimed to verify what effects horseback riding has in treating hospitalized patients with low back pain in the Korean medicine hospital. The method of this study is choosing 31 people among hospitalized male and female patients whose chief complaints were low back pain in 2 Korean medicine hospital in Gyeonggi Province. 14 people who agreed to take horseback riding treatment were classified into experimental group and 17, the rest of the people, were classified into control group. Both experimental group and control group were treated with Korean medicine. In addition, only experimental group performed horseback riding program. Changes of temperature difference by digital infrared thermal imaging(DITI), sit and reach test and visual analogue scale(VAS) survey were used as measuring tools. IBM SPSS Statistics 21 was used in processing statistics. Mean ${\pm}$standard deviation was indicated down to two places of decimals and the level of significance was judged as p<0.05. The summary of this study's result is as in the following. First of all, the meaningful difference was shown in the experimental group but not in the control group in the difference of temperature between Yintang and Kwanwon(the difference between up and down). Secondly, there were significant difference in the experimental group which performed horseback riding treatments but not in the control group resulting from examining the change of temperature difference between left and right Yongchon. Thirdly, there were significant difference between experimental and control group in the change of sit and reach. Especially, the change was much more in experimental group. As known from the results above, patients who only were treated with Korean medicine relieved low back pain, reordered pelvis and improved the motor ability. However, the group which carried out horseback riding at the same time reordered pelvis and improved the motor ability more obviously.

  • PDF

지르코니아 표면에칭처리와 저온열화현상이 지르코니아와 전장도재의 결합강도에 미치는 영향 (Effects on Bond Strength between Zirconia and Porcelain according to Etching Treatment and Low Temperature Degradation)

  • 박진영;김재홍;김웅철;김지환;김혜영
    • 치위생과학회지
    • /
    • 제14권2호
    • /
    • pp.140-149
    • /
    • 2014
  • 본 연구에서는 지르코니아 에칭에 의한 표면변화가 지르코니아 코어와 도재 사이의 결합강도에 미치는 영향을 조사하기 위해 전단결합강도 실시하였고, 표면의 변화를 관찰하기 위한 SEM 측정, 에칭처리에 따른 지르코니아의 성분변화를 알아보기 위해 EDS 분석을 실시하였다. 그리고 구강상태에서 15~20년의 저온열화현상을 재현하기 위해 저온 열화 처리를 시행하여 전단결합강도 평가를 실시하여 다음과 같은 결과가 도출되었다. 1. 에칭처리를 시행하지 않은 시편과 에칭처리를 시행한 시편의 전단결합강도를 비교할 경우 에칭한 시편의 전단결합강도가 큰 것을 알 수 있다. 이는 에칭용액이 지르코니아코어 표면에 interlocking을 형성하여 기계적인 결합을 높여 주었을 것이라고 생각된다. 2. 전단결합강도의 결과(EZ>AEZ>NEZ>ANEZ)를 보았을 때 통계적으로는 유의한 차이를 보였으며, 저온열화처리를 하지 않고 에칭처리를 한 EZ군이 전단결합강도가 가장 큰 것을 알 수 있었다. 또한 파절 양상에서도 EZ군에서만 응집파절을 보여 가장 결합강도가 높다는 결과를 도출할 수 있다. 결론적으로 저온열화처리 여부에 관계없이 표면에칭처리를 한 시편의 전단결합강도가 큰 것으로 나타나 지르코니아 표면의 에칭처리로 인한 interlocking의 형성이 기계적인 결합을 향상시키는 요인이 되었다고 생각된다.

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

복합레진 중합 광원에 따른 치수강 온도 변화에 대한 생체외 연구 (IN VITRO PULP CHAMBER TEMPERATURE CHANGE DURING COMPOSITE RESIN CURING WITH VARIOUS LIGHT SOURCES)

  • 이지영;김대업;이광희
    • 대한소아치과학회지
    • /
    • 제31권1호
    • /
    • pp.85-91
    • /
    • 2004
  • 연구목적은 복합레진 중합 광원에 따른 치수강 온도 변화를 관찰하는 것이었다. 연구에 사용된 광중합기는 일반 플라즈마아크 광중합기, 저발열 플라즈마 아크 광중합기, 저출력 할로겐 광중합기, 저출력 LED 광중합기, 고출력 LED 광중합기의 다섯 개이었다. K-type thermocouple 온도계를 사용하여, 중합기 light guide tip에서의 온도를 측정하고, 잔존 상아질 두께가 1mm가 되도록 형성한 유구치 와동에 상아질 접착제만 도포한 군, ionomer glass를 함유한 base 또는 calcium hydroxide를 함유한 base를 0.5mm두께로 이장한 군에서 각각 레진 충전 전과 후의 치수강내 온도를 측정하였다. 중합기 light guide tip에서 측정한 온도는 일반 플라즈마가 $52.94^{\circ}C$로 가장 높았고, 저출력 LED가 $26.14^{\circ}C$로서 가장 낮았다. 레진충전 전의 치수강내 온도는 고출력 LED가 $41.60{\sim}43.34^{\circ}C$로 가장 높았고, 저출력 LED는 $36.50{\sim}36.76^{\circ}C$로서 가장 낮았다. 레진 충전 후의 치수강내 온도는 고출력 LED가 $40.22{\sim}40.94^{\circ}C$로 가장 높았고, 저발열 플라즈마와 저출력 LED는 온도 상승이 없었다. Base의 사용은 부분적인 열 차단 효과가 있었다.

  • PDF

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

정상 및 암 세포주에서의 5-Aminolevulinic Acid에 의해 유도된 Protoporphyrin IX의 형광 검출을 위한 In Vitro 연구 (In Vitro Study of Fluorescence Detection for Protoporphyrin IX Induced from 5-Aminolevulinic Acid in Cancerous and Normal Cells)

  • 김명화;김현정;이인선;김경찬;이창섭
    • KSBB Journal
    • /
    • 제21권3호
    • /
    • pp.171-174
    • /
    • 2006
  • 형광을 이용한 암 진단을 위해 배양된 정상 및 암세포주에 광민감제인 5-ALA를 투여하고 세포 내 외에서 생성된 Protoporphyrin IX(PpIX)의 형광을 측정하여 5-ALA 투여의 최적농도를 조사하였다. 정상 간세포주(Chang) 및 자궁경부암 세포주(HeLa)에 5-ALA를 농도별로 투여하여 ALA에 의해 유도된 PpIX의 생성을 확인하고, MTT assay로 세포생존율을 측정하였다. 배양된 cell에 5-ALA를 투여한 후 24시간 동안 배양함으로써 생성되는 PpIX의 양은 형광의 강도로 측정하였다. HeLa 세포주에 대한 5-ALA의 최적농도는 $50{\mu}g/ml$이며, 이 때의 형광(emission) 스펙트럼은 여기 파장이 410 nm일 때 602.3 nm, 659.9 nm에서 형광 봉우리가 관찰되었다. PpIX의 형광 강도를 측정한 결과, PpIX는 정상세포에서는 낮은 농도로 축적이 되는 반면에 암세포에서 더 높은 농도로 축적되었으며, 세포 외보다는 세포 내에서 더 높은 농도로 축적됨을 알 수 있었다.

국가산림자원조사 DB와 임상도를 이용한 산림탄소저장량 공간분포 추정방법 비교 (Comparison of Three Kinds of Methods on Estimation of Forest Carbon Stocks Distribution Using National Forest Inventory DB and Forest Type Map)

  • 김경민;노영희;김은숙
    • 한국지리정보학회지
    • /
    • 제17권4호
    • /
    • pp.69-85
    • /
    • 2014
  • 기존의 산림탄소저장량 통계는 현지 조사 표본 기반의 통계로 표본점 단위에서는 비교적 정확하지만 미조사 지점에 대해서는 정확도가 떨어질 수 있다. 이를 보완하기 위한 것이 공간 정보를 보조 자료로 함께 활용하는 면적 기반 추정이며 우리나라의 경우 디지털 항공사진 판독과 현지 조사를 통해 상세 수준의 산림정보를 얻을 수 있는 1:5,000 임상도를 보유하고 있으므로 임상도의 활용성에 주목할 필요가 있다. 본 연구에서는 1:5,000 임상도와 제5차 국가산림자원조사 자료에 기반한 세 가지 업스케일링 방법을 비교하였다. 충청남도와 대전시를 대상으로 지도대수(방법 1), 회귀크리깅(방법 2) 및 지리가중회귀(방법 3)를 이용하여 산림탄소저장량을 각각 추정하였다. 탄소저장량 범위의 경우, 방법 2(1.39~138.80 tonC/ha)와 방법 3(1.28~149.98 tonC/ha)이 방법 1(0.00~93.37 tonC/ha)에 비해 기존의 현지 조사 표본 기반 방법의 추정치 범위(1.56~156.40 tonC/ha)와 유사한 범위로 추정하여 공간자기상관성을 고려한 회귀크리깅과 지리가중회귀 방법이 탄소저장량 분포의 공간이질성을 잘 반영하는 것으로 나타났다. 정확도 평가를 위해 독립검증 지점 186개소의 탄소저장량에 대한 대응표본 t-검정을 수행한 결과, 방법 2의 평균 추정치와 NFI 표본 기반 평균 추정치는 통계적으로 유의한 차이가 없으며(p>0.05) 방법 2의 결과가 가장 낮은 RMSE를 보였다. 따라서 지형과 임분 구조가 복잡한 우리나라 산림의 경우, 회귀크리깅이 기존 통계 방법과 가장 유사한 평균 탄소저장량을 산출하면서 탄소저장량의 국지적 변이를 나타내기에 유용할 것으로 판단된다.

Microcomputer를 이용(利用)한 농업기계요소(農業機械要素)의 Strain 측정(測定)에 관(關)한 연구(硏究) (Study on Strain Measurement of Agricultural Machine Elements Using Microcomputer)

  • 김기대;김태균;김성래
    • 농업과학연구
    • /
    • 제8권1호
    • /
    • pp.90-96
    • /
    • 1981
  • 농업기계(農業機械)의 개량(改良) 및 개발(改發)의 새로운 설계(設計)를 위(爲)하여는 기계요소(機械要素)의 strain의 정밀측정(精密測定)이 중요(重要)하다. 각종(各種) 농업기계요소(農業機械要素)의 strain 측정(測定)을 위(爲)하여 현재(現在) 널리 사용(使用)하고 있는 strain 계측장치(計測裝置)의 Recorder는 1,000m/s 이하(以上)의 고속측정(高速測定)에는 이용(利用)하기 어려울뿐아니라 포장(圃場)에서 실험(實驗)할 경우는 매우 불편(不便)하고 또한 Recording paper에 나타난 Analog Data를 인력(人力)에 의(依)해 Digital로 변환(變換)해야 하므로 이때의 분석소요시간(分析所要時間)이 많이 소요(所要)될 뿐 아니라 오차(誤差)의 발생요인(發生要因)도 많이 내포(內包)하고 있다. 본(本) 연구(硏究)는 Amplifier에서 출력(出力)되는 Analog Signal을 A/D 변환기(變換器)를 갖춘 마이크로 콤퓨터에서 실시간(實時間)으로 측정(測定)하고, 이를 보통의 카세트녹음기(錄音器)에 수록(收錄)하였다가 실험후(實驗後) 콤퓨터에 보내 처리(處理)하는 방안(方案)에 관(關)해 연구(硏究)를 실시(實施)한 바 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 측정시간간격(測定時間間隔), 사용(使用) channel수(數) 및 data수(數)를 자유(自由)로 조정(調整)할 수 있는 측정(測定) program을 개발(開發)하였으며 특(特)히 측정시간(測定時間) 간격(間隔)은 고속측정(高速測定)이 최소(最少) $62{\mu}s$까지 가능(可能)하였다. 2. Calibration은 funcfion generator와 Oscilloscope를 이용(利用)하여 삼각파(三角波)를 넣어 측정(測定)한 결과(決果)를 콤퓨터에서 plotling한 결과(結果) 정확(正確)한 삼각파(三角波)를 얻을 수 있어 phase distorsion, amplitude distorsion의 문제(問題)가 전혀 없는 것이 인정(認定)되었다. 3. 진동주기(振動週期)가 0.019초(秒)인 Cantilever beam vibrafor의 strain 변화(變化)를 이 실험장치(實驗裝置)로 측정시간(測定時間) 간격(間隔) 1.0ms로 측정(測定)하여 콤퓨터에서 plotting한 결과(結果) 이론치(理論値)와 잘 일치(一致)하는 진동곡선(振動曲線)을 얻었다. 4. 마이크로 콤퓨터는 농업기계요소(農業機械要素)의 strain 측정(測定)에 이용(利用)하면 분석시간(分析時間)이 절약(節約)되고 기록용지(記錄用紙)를 사용(使用)치 않아 경제적(經濟的)일 뿐 아니라 포장실험(圃場實驗) 적응성(適應性)이 우수(優秀)하고 정밀고속측정등(精密高速測定等) 우수(優秀)한 성능(性能)을 갖춘 것으로 인정(認定)된다.

  • PDF

영상 기반 3차원 점군과 FUSION S/W 기반의 임분고 분석 모듈 개발 (Development of Mean Stand Height Module Using Image-Based Point Cloud and FUSION S/W)

  • 김경민
    • 한국지리정보학회지
    • /
    • 제19권4호
    • /
    • pp.169-185
    • /
    • 2016
  • 최근 임상도의 신규 속성으로 임분의 평균 수고인 임분고를 추가하기 시작하였으나 전국 940만개의 포인트를 스테레오 항공사진에서 수동 측정해야 하는 어려움이 예상된다. 아울러, 항공사진에서 수고 측정 시 임연부나 묘지 주변의 수고를 측정하기 쉬워 임분 대표성이 떨어지는 한계를 가지고 있다. 본 연구에서는 고해상도 스테레오 항공사진에서 추출한 영상 기반 3차원 점군과 FUSION S/W를 활용한 임분고 추정 방법을 제안하고 임분고를 자동 분석할 수 있는 모듈을 개발하였다. 스테레오 항공사진에서 수치표면모델 3차원 점군을 추출한 후 지면점 필터링을 거쳐 수치지면모델을 추출하고 이 두 모델을 차분하여 정규수치표면모델을 제작하였다. 정규수치표면모델에서 표본점별 개체목 수관을 육안판독한 후 수관별 최고점을 추출하여 정규수치표면모델 수고를 산출하였다. 표본점에서의 실측 수고와 정규수치표면모델 수고의 RMSE를 분석한 결과 전체 표본점 평균 수고의 RMSE는 0.96m로 나타났다. 대상지 전체의 개체목 수고를 추출하기 위해 FUSION S/W를 이용하여 항공사진의 정규수치표면모델에서 개체목 수고를 자동 추출하고 이를 임상도의 임분 폴리곤 단위로 평균하여 최종 임분고를 산출하였다. 마지막으로 임분고를 보다 손쉽게 분석할 수 있는 환경을 구현하기 위해 임분고 분석 프로세스를 ArcGIS add-in 모듈 형태로 자동화하였다.

새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력 (Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading)

  • 이주희
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.151-155
    • /
    • 2017
  • 목적: 이 연구의 목적은 새로운 타이타늄 구성요소를 가진 지르코니아 지대주의 나사 제거력의 변화에 대해 알아보는 것이다. 내부연결 임플란트를 위한 새로운 지르코니아 지대주의 동적하중 후 지대주 나사의 제거력을 기존의 타이타늄 지대주와 비교하여 분석하였다. 재료 및 방법: 내측연결 임플란트와 타이타늄 지대주, 타이타늄 구성요소를 가진 지르코니아 지대주를 준비하였다. 12개의 내부연결형 임플란트에 6개의 타이타늄 지대주를 연결하고(대조군), 6개의 타이타늄 구성요소를 가진 지르코니아 지대주(실험군)를 30 Ncm의 토크로 연결한 후 동적하중 전후의 나사 제거력을 측정하였다. 동적 만능재료시험기를 사용하여 연결체의 장축과 30도 각도를 이루도록 하고 300 N 하중크기로 100만번의 하중이 가해졌다. 동적하중 전후의 지대주 나사 제거력을 t검정을 통해 신뢰구간 95%로 통계적 유의성을 검증하였다. 결과: 두 그룹 모두에서 동적하중 후 나사 풀림을 보이지 않았다. 동적 하중 전후의 나사 제거력은 두 그룹 모두에서 통계적으로 유의한 차이가 있게 나타났다(P < .05). 동적 하중 전후의 나사 제거력 차이는 대조군에서 $-7.25{\pm}1.50Ncm$, 실험군에서 $-7.33{\pm}0.93Ncm$ 로 나타났다. 통계분석 결과 두 군간에 나사 제거력 차이에서는 유의한 차이를 보이지 않았다(P > .05). 결론: 이 실험의 결과에 한하여 타이타늄 구성요소를 사용한 지르코니아 지대주의 동적하중 후 지대주 나사 제거력의 변화는 타이타늄 지대주와 통계학적으로 유의한 차이를 보이지 않았다.