• Title/Summary/Keyword: diffuser effect

Search Result 145, Processing Time 0.022 seconds

A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser (폐색 저감형 산기관의 개발 및 적용성 평가)

  • Kim, Young-Hoon;Kim, Kwan-Yeop;Lee, Eui-Jong;Nam, Jong-Woo;Lee, Chang-Ha;Jeon, Min-Jung;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.

Effect on Stratification due to Diffuser Shape in a Thermal Storage Tank (온도 성층축열조 가시화 및 실증분석에 관한 고찰)

  • Lee Young-Soo;Lee Sang-Nam;Kim Jong-Ryul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.990-997
    • /
    • 2005
  • The stratified effect was investigated with three different types of diffuser shape in a thermal storage tank with variation of diffuser diameter, velocity, Froude number etc. Its effect was estimated by the degree of stratification. No matter of diffuser diameter and shape, the degree of stratification was the best as the Froude number gets closer to 1. In the case of a curved diffuser, when its diameter is a quarter of tank diameter and ejection velocity in a diffuser is approximately 0.2 m/s, the Froude number was almost 1. In the case of a flatted diffuser, when ejection velocity was 0.05 m/s, the Froude number was 1.5. Both cases which Froude number were nearer 1, showed the good degree of stratification.

Effect of Diffuser Shape on the Performance of Water-Chilled Heat Storage (축열조 성능에 미치는 디퓨저 형상의 영향)

  • 정재동;박주혁;조성환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.374-382
    • /
    • 2004
  • Diffuser design is crucial for water-chilled heat storage. Its impact on the system performance is more significant for the underground tank due to inherent limit on the aspect ratio and tank shape. The effect of diffuser shape on the performance of the water-chilled heat storage is numerically investigated. Three dimensional simulation has been conducted for fully incorporating the complex diffuser shape and the non-symmetric tank shape. Mixing at the inlet of the diffuser depends on the inlet Reynolds number, Froude number and the diffuser shape. Three types of the diffuser shape and the broad range of Reynolds number (Re=400, 800, 1200) and Froude number (Fr=0.5, 1.0, 2.0) are examined. The performance of the heat storage tank is evaluated by the thermocline thickness which is reverse to the degree of stratification. The radial regulated plate diffuser, which is the suggested diffuser shape in this study, shows the lowest thermocline thickness in the condition considered.

Effect of Diffuser Width on Rotating Stall in Centrifugal with Vaneless Diffuser (원심형 송풍기에서 베인리스 디퓨저의 폭변화가 선회실속에 미치는 영향)

  • Kim, Jin-Hyeong;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1293-1302
    • /
    • 2001
  • It is generally known that radial vane blowers with vaneless diffuser may generate mostly only a rotating stall but backward curved vane blowers may do both an impeller and a diffuser rotating stalls. In this study, it was found from the numerical and experimental results that the diffuser rotating stall does not appear in a radial vane because of the suppression for the diffuser stall appearance by occurring of impeller rotating stall in a large flow rate coefficient. The diffuser rotating stalls occurring when the width of diffuser is broaden fur a backward curved vane blower are classified definitely by the diffuser flow rate coefficient defined by adopting the varying diffuser width.

The effect of pinched diffuser on aerodynamic performance in a centrifugal compressor (Pinch 디퓨저를 사용한 원심압축기의 공력성능 연구)

  • O, Jong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3639-3648
    • /
    • 1996
  • The effect of 15% pinched diffuser in a centrifugal air compressor with a cascade airfoil diffuser on the aerodynamic performance is investigated using a numerical approach. The commercial CFD code for three-dimensional, turbulent, compressible flow fields is executed for various mass flow rates at a design speed which can be obtained as long as the calculation succeeds. The pinched diffuser is found to help improve the instability of flow within vaneless diffuser space, especially the reverse flow near shroud, and to change both stall/surge line and choking line to increase the surge margin. It is also found to generate more favorable increase of static pressure in diffuser region, and to increase the resulting pressure ratio and efficiency.

ANALYSIS OF THE MIXING BEHAVIOR OF THE HEATED WATER FROM THERMAL DIFFUSER

  • Seo Il Won;Jeon Tae Myoung;Son Eun Woo;Kwon Seok Jae
    • Water Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.1-15
    • /
    • 2005
  • The numerical model, FLUENT, was employed to investigate the effect of the heated water discharged from the diffuser of Boryung Power Plant. Temperature patterns of the thermal effluent discharged from two proposed types of the diffusers was evaluated for maximum flood and maximum ebb tide. The hydraulic model experiments were also performed in the reduced scale of 1/150 to verify the numerical simulation results. The buoyant jets discharged from the diffusers were found to be significantly affected by the ambient flows beyond the region where the effluent momentum was dissipated. Both the numerical and experimental results showed that the area of the excess isotherm for Type 1 diffuser was larger than that for Type 2 diffuser. Type 2 diffuser system was observed to be a more effective diffuser design than Type 1 diffuser system based on the temperature reduction and excess isotherm obtained from the numerical simulation in the ambient flows.

  • PDF

Investigation of the noise sources for the centrifugal fan and aeroacoustic noise prediction (진공청소기 원심 홴의 소음원 분석 및 공력 소음 예측)

  • Jeong, Ye-Eun;Bae, Young-Min;Moon, Young-J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.645-645
    • /
    • 2009
  • In many practical applications of the centrifugal fan, the impeller-diffuser interaction noise is considered as a main source of fan noise. The housing for an electric motor is also expected to play an important role on noise propagation because of its complicated configuration. This study investigates the impeller-diffuser interaction noise and its sources by computing three-dimensional, incompressible flow field of the centrifugal fan in motor housing. The effect of motor case on fan noise characteristic is then investigated using the Brinkman penalization method, while the noise source associated with impeller-diffuser interaction is mathematically modeled. It is found that the present methodology combined with mathematical description of noise source provides a fairly good agreement with the experimental results, indicating that the motor housing has significant effect on noise characteristics. Finally, aeroacoustic noise prediction for various impeller-diffuser blade count ratios is conducted for noise reduction.

  • PDF

Experimental Study and Numerical Simulation of Cavity Oscillation in a Conical Diffuser

  • Chen, Chang-Kun;Nicolet, Christophe;Yonezawa, Koichi;Farhat, Mohamed;Avellan, Francois;Miyazawa, Kazuyoshi;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.1
    • /
    • pp.91-101
    • /
    • 2010
  • Based on the one-dimensional stability analysis, the self-excited oscillation in hydraulic power generating systems was studied by a simple experiment and numerical simulation. It was shown that a cavity in a conical diffuser can cause surge. With the diffuser, a high amplitude and low frequency oscillation occurs at low cavitation number. This oscillation was not observed with the straight pipe. It was confirmed that the diffuser effect of the draft tube can be the cause of the full load surge in hydraulic power system. Numerical results were also analyzed to check the validity of the one-dimensional stability analysis.

Application of Constant Rate of Velocity or Pressure Change Method to Improve Annular Jet Pump Performance

  • Yang, Xuelong;Long, Xinping;Kang, Yong;Xiao, Longzhou
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.3
    • /
    • pp.137-143
    • /
    • 2013
  • To improve annular jet pump (AJP) performance, new ways named constant rate of velocity/pressure change method (CRVC/CRPC) were adopted to design its diffuser. The design formulas were derived according to the assumption of linear velocity/pressure variation in the diffuser. Based on the two-dimensional numerical simulations, the effect of the diffuser profile and the included angle on the pump performance and the internal flow details has been analyzed. The predicted results of the RNG k-epsilon turbulence model show a better agreement with the experiment data than that of the standard and the realizable k-epsilon turbulence models. The AJP with the CRPC diffuser produces a linear pressure increase in the CRPC diffuser as expected. The AJP with CRPC/CRVC diffuser has better performance when the diffuser included angle is greater or the diffuser length is shorter. Therefore, the AJP with CRPC/CRVC diffuser is suitable for applications requiring space limitation and weight restriction.

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.