• 제목/요약/키워드: diffuse light

검색결과 221건 처리시간 0.027초

만성 연중독자에서 발생한 신장해 (Nephropathy in Chronic Lead Poisoning)

  • 김병권;김성률;홍영습;나서희;김정만;정갑열;김준연
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권1호
    • /
    • pp.43-50
    • /
    • 1996
  • We experienced a case of nephropathy in chronic lead poisoning. The patient was 43-year-old male who has been working in secondary lead smelting plant for 14 years. On admission, blood pressure was 160/90 mmHg and the others were non-specific. In past history, he received chelating agent administration for lead poisoning irregularly and medicated for gout, and the blood lead concentration was $180.0{\mu}g/dl$ on 2 months before admission. Smoking habit has been 1 pack per day for 15 years and drinking habit has been 1 bottle of Soju per day but less flow. In liver function test, AST/ALT were 27/28 IU/l and $\gamma-GT$ was 456 IU/l. In blood test, Hb : 11.5 g/dl, Hct : 34.0% and basophilic stipplings were found in peripheral blood smear. Chest PA was normal and abdominal ultrasonographic finding was non-specific except fatty liver. In the test of lead exposure indices, $PbB:83.0{\mu}g/dl,\;PbU:28.3{\mu}g/l$, and blood ZPP was $300.0{\mu}g/dl$. And in renal function test, BUN : 31.4 mg/dl, blood creatinine : 2.7mg/dl, blood uric acid. 9.1 mg/dl, urinary albumin : 100.0 mg/g creatinine, urinary $\alpha_1-microglobulin$ : 120.5 mg/g creatinine, urinary $\beta_2-microglobulin$ : $183.8{\mu}g/g$ creatinine, and 24 hours urinary creatinine clearance was 31.9 ml/min. The ultrasonoguided renal biopsy showed the global sclerosis of glomerulus, moderate atrophy and loss of tubule, and interstitial fibrosis in light microscopy. There were diffuse losses of brush border of proximal tubule in electronmicroscopy.

  • PDF

소아에서 관찰된 IgG-associated mesangial glomerulonephritis 2례 (Two Cases of IgG-associated Mesangial Glomerulonephritis in Children)

  • 이상후;김병길;송지선
    • Childhood Kidney Diseases
    • /
    • 제12권1호
    • /
    • pp.93-98
    • /
    • 2008
  • IgG 신병증(IgG-associated mesangial glomerulonephritis)은 전세계적으로 드물게 보고되고 있는 새로운 원발성 사구체 질환으로 1993년 Sato 등에 의해 처음으로 보고되었고 이후 1994년 Yoshikawa 등에 의해 소아에서의 10례가 보고되었다. 주로 단백뇨를 주소로 하며 현미경적 혈뇨를 동반하기도 한다. 이 질환은 조직 면역 형광 검사상 사구체 간질에 IgG의 침착을 보이는 사구체 신염이다. 이 질환은 초기에는 양성 경과를 취하는 것으로 알려졌으나 2002년 Fakhouri 등은 대부분은 양성 경과를 보이지만 일부는 말기 신부전증으로 진행함을 관찰할 수 있었으며 1례에서는 신장이식 후 이식신에서 IgG 신병증이 재발된 예도 보고 하였다. 본 증례에서는 한명은 신증후군이 동반되었고 한명은 무증상 현미경적 혈뇨만을 보였다. 이들 모두 면역 형광 현미경 소견상 사구체 간질에 IgG 침착이 주로 보였고 IgM, 보체의 침착도 보였다. 또한 전자현미경 소견상 사구체간질에 고밀도 전자 침착이 보였다. 신생검에서 면역 현미경 소견과 전자 현미경 소견으로 진단된 IgG 신병증 소아환자 2례를 경험하고 국내에서는 아직 보고된 예가 없기에 문헌 고찰과 함께 증례를 보고하는 바이다.

  • PDF

광촉매 TiO2의 황산용액에서의 양극산화전압과 도핑이 광촉매 활성에 미치는 영향 (Effects of Anodic Voltages of Photcatalytic TiO2 and Doping in H2SO4 Solutions on the Photocatalytic Activity)

  • 이승현;오한준;지충수
    • 한국재료학회지
    • /
    • 제22권8호
    • /
    • pp.439-444
    • /
    • 2012
  • To compare the photocatalytic performances of titania for purification of waste water according to applied voltages and doping, $TiO_2$ films were prepared in a 1.0 M $H_2SO_4$ solution containing $NH_4F$ at different anodic voltages. Chemical bonding states of F-N-codoped $TiO_2$ were analyzed using surface X-ray photoelectron spectroscopy (XPS). The photocatalytic activity of the co-doped $TiO_2$ films was analyzed by the degradation of aniline blue solution. Nanotubes were formed with thicknesses of 200-300 nm for the films anodized at 30 V, but porous morphology was generated with pores of 1-2 ${\mu}m$ for the $TiO_2$ anodized at 180 V. The phenomenon of spark discharge was initiated at about 98 V due to the breakdown of the oxide films in both solutions. XPS analysis revealed the spectra of F1s at 684.3 eV and N1s at 399.8 eV for the $TiO_2$ anodized in the $H_2SO_4-NH_4F$ solution at 180 V, suggesting the incorporation of F and N species during anodization. Dye removal rates for the pure $TiO_2$ anodized at 30 V and 180 V were found to be 14.0% and 38.9%, respectively, in the photocatalytic degradation test of the aniline blue solution for 200 min irradiation; the rates for the F-N-codoped $TiO_2$ anodized at 30 V and 180 V were found to be 21.2% and 65.6%, respectively. From the results of diffuse reflectance absorption spectroscopy (DRS), it was found that the absorption edge of the F-N-codoped $TiO_2$ films shifted toward the visible light region up to 412 nm, indicating that the photocatalytic activity of $TiO_2$ is improved by appropriate doping of F and N by the addition of $NH_4F$.

Extragalactic Sciences from SPICA/FPC-S

  • 정웅섭;;임명신;이형목;이정은;;;;이대희;표정현;박성준;문봉곤;박귀종;박영식;한원용;남욱원
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.36.2-36.2
    • /
    • 2013
  • The SPICA (SPace Infrared Telescope for Cosmology & Astrophysics) project is a next-generation infrared space telescope optimized for mid- and far-infrared observation with a cryogenically cooled 3m-class telescope. The focal plane instruments onboard SPICA will enable us to resolve many astronomical key issues from the formation and evolution of galaxies to the planetary formation. The FPC-S (Focal Plane Camera - Sciecne) is a near-infrared instrument proposed by Korea as an international collaboration. Owing to the capability of both low-resolution imaging spectroscopy and wide-band imaging with a field of view of $5^{\prime}{\times}5^{\prime}$, it has large throughput as well as high sensitivity for diffuse light compared with JWST. In order to strengthen advantages of the FPC-S, we propose the studies of probing population III stars by the measurement of cosmic near-infrared background radiation and the star formation history at high redshift by the discoveries of active star-forming galaxies. In addition to the major scientific targets, to survey large area opens a new parameter space to investigate the deep Universe. The good survey capability in the parallel imaging mode allows us to study the rare, bright objects such as quasars, bright star-forming galaxies in the early Universe as a way to understand the formation of the first objects in the Universe, and ultra-cool brown dwarfs. Observations in the warm mission will give us a unique chance to detect high-z supernovae, ices in young stellar objects (YSOs) even with low mass, the $3.3{\mu}$ feature of shocked circumstance in supernova remnants. Here, we report the current status of SPICA/FPC project and its extragalactic sciences.

  • PDF

Effects of DC Biases and Post-CMP Cleaning Solution Concentrations on the Cu Film Corrosion

  • Lee, Yong-K.;Lee, Kang-Soo
    • Corrosion Science and Technology
    • /
    • 제9권6호
    • /
    • pp.276-280
    • /
    • 2010
  • Copper(Cu) as an interconnecting metal layer can replace aluminum (Al) in IC fabrication since Cu has low electrical resistivity, showing high immunity to electromigration compared to Al. However, it is very difficult for copper to be patterned by the dry etching processes. The chemical mechanical polishing (CMP) process has been introduced and widely used as the mainstream patterning technique for Cu in the fabrication of deep submicron integrated circuits in light of its capability to reduce surface roughness. But this process leaves a large amount of residues on the wafer surface, which must be removed by the post-CMP cleaning processes. Copper corrosion is one of the critical issues for the copper metallization process. Thus, in order to understand the copper corrosion problems in post-CMP cleaning solutions and study the effects of DC biases and post-CMP cleaning solution concentrations on the Cu film, a constant voltage was supplied at various concentrations, and then the output currents were measured and recorded with time. Most of the cases, the current was steadily decreased (i.e. resistance was increased by the oxidation). In the lowest concentration case only, the current was steadily increased with the scarce fluctuations. The higher the constant supplied DC voltage values, the higher the initial output current and the saturated current values. However the time to be taken for it to be saturated was almost the same for all the DC supplied voltage values. It was indicated that the oxide formation was not dependent on the supplied voltage values and 1 V was more than enough to form the oxide. With applied voltages lower than 3 V combined with any concentration, the perforation through the oxide film rarely took place due to the insufficient driving force (voltage) and the copper oxidation ceased. However, with the voltage higher than 3 V, the copper ions were started to diffuse out through the oxide film and thus made pores to be formed on the oxide surface, causing the current to increase and a part of the exposed copper film inside the pores gets back to be oxidized and the rest of it was remained without any further oxidation, causing the current back to decrease a little bit. With increasing the applied DC bias value, the shorter time to be taken for copper ions to be diffused out through the copper oxide film. From the discussions above, it could be concluded that the oxide film was formed and grown by the copper ion diffusion first and then the reaction with any oxidant in the post-CMP cleaning solution.

시뮬레이션을 이용한 외부 베네시안 블라인드의 약식 SHGC 계산법 개발 (The Development of the Simple SHGC Calculation Method in Case of a Exterior Venetian Blind Using the Simulation)

  • 엄재용;이충국;장월상;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.73-83
    • /
    • 2015
  • When it comes to these buildings for business use, cooling load during summertime was reported to have great importance which, as a result, impressively increased interest in Solar Heat Gain Coefficient (SHGC). Such SHGC is considered to be lowered with the help of colors and functions of glass itself, internal shading devices, insulation films and others but basically, these external shading devices for initial blocking that would not allow solar heat to come in from outside the buildings are determined to be most effective. Of many different external shading devices, this thesis conducted an analysis on Exterior Venetian Blind. As for vertical shading devices, previous researches already calculated SHGC conveniently using concepts of sky-opening ratios. However in terms of the Venetian Blind, such correlation is not possibly applied. In light of that, in order to extract a valid correlation, this study first introduced a concept called shape factor, which would use the breadth and a space of a shade, before carrying out the analysis. As a consequence, the concept helped this study to find a very similar correlation. Results of the analysis are summarized as follows. (1) Regarding SHGC depending on the surface reflectance of a shade, an average of 2% error is observed and yet, the figure can always be ignored when it comes to a simple calculation. (2) As for SHGC of each bearing, this study noticed deviations of 4% or less and in the end, it is confirmed that extraction can be achieved with no more than one correlation formula. (3) When only the shape factor and nothing else is used for finding a correlation formula, the formula with a deviation of approximately 5% or less is what one would expect. (4) Since the study observed slight differences in bearings depending on ranges of the shape factors, it needed to extract a weighted value of each bearing, and learned that the smaller the shape factor, the wider the range of a weighted value. The study now suggests that a follow-up research to extract a simple calculation formula by dealing with all these various inclined angles of shade, solar radiation conditions of each region (the ratio of diffuse radiation to direct radiation and others) as well as seasonal features should be carried out.

LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구 (Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires)

  • 이진숙;김원도;김병수;한원탁
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.1-7
    • /
    • 2008
  • 본 연구의 목적은 형광등조명기구와 LED 조명기구와의 물리적 특성을 비교하여 LED조명기구의 기본적인 특성을 분석하는데 있다. 여기서 두가지 조명기구의 균제도 및 휘도분포 측면에서 비교 분석하여 LED조명기구를 건축실내공간에 적용하기 위한 자료를 작성하였다. 연구는 4단계로 나누어 진행하였다. 첫째, 기존의 조명기구와 비교한 LED조명광원의 이론적인 검토를 하였다. 둘째, 연구의 목적에 부합되도록 실험변인을 조절할 수 있는 실물대모형(Mock-up)을 제작하였다. 셋째, 설치된 실물대의형을 이용하여 조명기구별 균제도 휘도분포를 측정하였다. 최종적으로, 기존의 형광등기구와 LED조명기구간의 균제도 휘도분포 특성을 비교분석하였다. 연구결과 LED조명기구가 균제도 0.569로 기존 형광등조명기구의 균제도 0.522보다 높아 균일한 조도분포 특성을 보이고 전반확산이 양호한 것으로 나타났다. 또한 휘도분포를 측정한 결과 LED조명기구가 보다 균일한 휘도분포 특성을 보였고, 벽면의 휘도분포는 형광등조명기구에 의한 최대휘도가 $180.6[cd/m^2]$, LED조명기구는 $155.26[cd/m^2]$로 형광등이 높고, 평균휘도는 형광등조명기구가 $44.32[cd/m^2]$, LED조명기구가 $58.65[cd/m^2]$로 LED조명기구가 높게 나타났다. 이상의 결과로 볼 때, LED조명기구가 형광등조명기구보다 재실자에게 보다 쾌적한 작업환경을 구성할 수 있는 조명이라 판단된다.

생체피부에서의 잠재지문 현출 (Developing of latent fingerprint on human skin)

  • 이희일;최미정;김재훈;박성우
    • 분석과학
    • /
    • 제21권3호
    • /
    • pp.222-228
    • /
    • 2008
  • 생체피부에서의 잠재지문 현출에는 많은 제한점이 있다. 살아있는 피부는 계속적인 발한을 하고 지방친화성이 있어 흡수 및 확산에 의해 지문변화를 초래하기 때문이다. 본 연구는 사람피부에 존재하는 잠재지문의 효과적 현출방법을 알아보기 위하여 살아있는 생체피부와 피부유사 돼지피부를 이용하여 수행되었다. 피부지문현출제로는 흑색, 형광 분말 및 자석분말 그리고 Cyanoacrylate fuming을 이용하였으며 전사법으로는 전사지(lifting paper), 유리, 사진현상용 glossy paper를 이용하여 피부로부터 전사한 후 현출하였다. 살아있는 피부에 존재하는 즉시지문일 경우에는 흑색분말인 S-powder, Cyanoacrylate fuming법 및 훈증후 흑색 또는 형광분말로의 재처리에 의해 현출이 가능하였고 자석분말로의 현출로는 지문이나 배경피부에 과도하게 흡착되는 경향을 볼 수 있었으며 유류에 따라 지문이 사라짐을 알 수 있었다. 사체유사 돼지피부에서는 6시간 유류된 지문에서도 $25^{\circ}C$, 40%에서 1분간의 Cyanoacrylate fuming법 이후 흑색분말로의 재현출하였을 때 잠재지문의 현출이 가능함을 알 수 있었으며 현출된 지문영상에 다양한 스펙트럼을 이용한 감식영상의 효과적 조사파장에 대한 결과를 얻을 수 있었다.

5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구 (The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance)

  • 정해조;김희중;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.98-106
    • /
    • 2007
  • 2005년 6월 연세의료원 세브란스병원에서는 진단목적으로 20대의 5 mesa 화소 Totoku ME511L 평판 LCD 표시장치를 추가하여 PACS를 확장하였다. 20대의 Totoku ME511L 표시장치를 대상으로 반사, 휘도 반응, 휘도 공간 의존, 분해능, 잡음, 베일링 그레어, 그리고 색도 항목에 대하여 AAPM TG 18보고서에 기준하여 정량적인(또는 시각적인) 인수검사를 실시하였다. 측정에 사용된 장치는 색도를 측정할 수 있는 만원경식 휘도계, 조도계, 반사 측정에 필요한 빛 선원, 빛 차단 장치, 그리고 TG18 테스트 패턴들이었다. 선택된 8대의 표시장치에 대한 평균 확산 반사계수($R_d$)는 $0.019{\pm}0.02sr^{-1}$이었다. 휘도 반응 검사에서, 휘도비(LR), 최대 휘도 변이($L_{max}$), 그리고 최대 대조도 반응 변이는 각각 $550{\pm}100,\;2.0{\pm}1.9%$, 그리고 $5.8{\pm}1.8%$이었다. 휘도 균일도 검사에서, 최대 휘도 변이는 TG18-UNL10 테스트 패턴의 10% 휘도에 대하여 $14.3{\pm}5.5%$이었다. 분해능 측정은 휘도 측정법으로 수행하였으며 중심에서 퍼센트 휘도(${\Dalta}L$)는 $0.94{\pm}0.64%$이었다. 시각적인 방법의 잡음측정의 모든 경우에서, 중앙 및 주위 4사분면에서 가장 작은 것을 제외하고 15개의 모든 정사각형의 표적을 인식할 수 있었다. 글레어 비(GR)은 $12,346{\pm}1,995$이었다. 최대 색도 균일도 지표(D)는 $0.0025{\pm}0.0008$이었다. 또한 국내 실정에 적합한 진단용 표시장치의 정도관리 가이드라인 연구 결과를 제시하였다. 모든 인수검사 결과는 AAPM TG18 보고서 기준에 포함되어 진단 목적으로 사용하기에 적합하였다. 결론으로 인수검사는 표시장치가 진단에 사용하기에 적합한 성능임을 알려줄 뿐만 아니라 정도관리의 가이드라인, 최적 판독 환경, 그리고 표시장치의 교체시기를 결정하여주는 중요한 역할을 할 수 있다.

  • PDF

교질상 적철석의 거동 특성: 수환경 내 이온 조성 및 세기, 자연 유기물이 미치는 영향 (Study on the Behavior of Colloidal Hematite: Effects of Ionic Composition and Strength and Natural Organic Matter in Aqueous Environments)

  • 이우춘;이상우;김순오
    • 자원환경지질
    • /
    • 제53권4호
    • /
    • pp.347-362
    • /
    • 2020
  • 수환경 내 철 (수산)산화물은 주로 광산 활동에 의해 생성되며 주변 환경을 교란시키는 대표적인 교질물이다. 철 (수산)산화물들 중 지표에 많이 분포하고 있는 적철석은 수환경 내 다양한 환경인자들로 인해 거동 특성이 변한다. 본 연구는 배경용액의 이온 조성과 세기, pH, 자연 유기물 등의 환경적 인자가 교질상 적철석의 거동에 미치는 영향을 살펴보고자 수행되었다. 특히, 적철석 교질물 입자들의 거동특성을 보다 더 명확하게 해석하고자 동적광산란분석기(dynamic light scatterer, DLS)와 단일입자 유도결합플라즈마질량분석기(single particle ICP-MS, spICP-MS)를 비교하여 분석을 수행하였다. 배경용액의 이온 조성과 세기가 변함에 따라 적철석 입자의 표면 확산이중층의 두께가 변화될 뿐만 아니라, 입자에 미치는 정전기적 힘과 van der Walls의 합력이 변하면서 입자의 응집/분산 특성이 달라지는 것으로 나타났다. 또한 수환경의 pH가 적철석 입자의 영전하점(point of zero charge, PZC)에서 멀어질수록 정전기적 반발력이 커져 입자들이 분산되는 것을 확인하였다. 수환경 내 자연 유기물이 적철석의 표면을 코팅함에 따라서 자연 유기물 표면에 존재하는 카르복실기와 페놀기 등과 같은 작용기들로 인하여 적철석 입자의 정전기적 안정화와 구조적 안정화가 증가하는 것으로 조사되었다. 이러한 안정화 효과는 자연 유기물의 농도가 작을수록 증가하지만, 상대적으로 이온포텐셜이 큰 2가 양이온이 1가 양이온보다 자연 유기물로 코팅된 적철석 입자들 사이에서 더 큰 가교역할을 하기 때문에 자연 유기물로 코팅된 적철석 입자들의 안정화(분산)를 방해하는 것으로 확인되었다. 결론적으로, 수환경 내 교질상 적철석의 거동 특성은 이온의 조성과 세기, pH, 그리고 자연 유기물 등과 같은 환경적 인자들에 많은 영향을 받는 것을 정량적으로 확인할 수 있었는데, 그 중 자연 유기물은 수환경에서 교질물의 거동에 매우 지배적이고 주요한 제어인자임을 알 수 있었다. 한편, 적철석 입자의 거동 특성을 정량화할 수 있는 두 분석기법을 비교한 결과, DLS 분석기법은 신속성 및 편의성에서 강점을 지니는 반면 spICP-MS의 분석기법은 입자의 모양 및 응집 형태 등을 고려할 수 있는 장점이 있기 때문에 두 분석기법을 조합하여 활용하면 수환경 내 교질물의 거동 특성을 연구하는데 보다 더 효과적일 것으로 판단된다.