• Title/Summary/Keyword: diffuse light

Search Result 222, Processing Time 0.031 seconds

A Case of Brain Edema Complicated by Whole Lung Lavage to Treat Pulmonary Alveolar Proteinosis (폐포 단백증 치료를 위한 전폐세척술 후 발생한 뇌부종 1예)

  • Moon, Hee-Yong;Kim, Se-Kyu;Shin, Dong-Whan;Lee, Ki-Myung;Chang, Jung-Hyun;Kwak, Seung-Min;Lee, Hong-Lyeol;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.158-164
    • /
    • 1994
  • Pulmonary alveolar proteinosis is a disease of unknown etiology characterized by the accumulation of PAS positive lipoproteinaceous material in the alveolar spaces sparing septum. The therapy which has enjoyed the greatest success is whole lung lavage. The authors reported here, a case of 44 year old male patient with pulmonary alveolar proteinosis, and this is the 7th case in Korea. The patient underwent whole lung lavage but expired due to brain edema complicated by the procedure. He complained exertional dyspnea and cyanotic lips, and presented fine inspiratory crackle at both lower lung fields, decreased arterial oxygen pressure, and diffuse infiltration at whole lung field. Light microscopic finding of lung tissue obtained by transbronchial lung biopsy revealed PAS positive amorphous, granular material filled in the alveolar spaces, and electron microscopy of bronchoalveolar lavage fluid concentrate showed many electron-dense multi-lamellated structures. To treat the disease, the authors tried whole lung lavage of left lung with $37^{\circ}C$ isotonic saline under general anesthesia. However, he expired due to brain edema probably due to dilutional hyponatremia complicated by the procedure, 11 days after the procedure. Whole lung lavage is known relatively safe, but fatal complication may occur like this case.

  • PDF

Nephropathy in Chronic Lead Poisoning (만성 연중독자에서 발생한 신장해)

  • Kim, Byoung-Gwon;Kim, Sung-Ryul;Hong, Young-Seoub;Rha, Seo-Hee;Kim, Jung-Man;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.43-50
    • /
    • 1996
  • We experienced a case of nephropathy in chronic lead poisoning. The patient was 43-year-old male who has been working in secondary lead smelting plant for 14 years. On admission, blood pressure was 160/90 mmHg and the others were non-specific. In past history, he received chelating agent administration for lead poisoning irregularly and medicated for gout, and the blood lead concentration was $180.0{\mu}g/dl$ on 2 months before admission. Smoking habit has been 1 pack per day for 15 years and drinking habit has been 1 bottle of Soju per day but less flow. In liver function test, AST/ALT were 27/28 IU/l and $\gamma-GT$ was 456 IU/l. In blood test, Hb : 11.5 g/dl, Hct : 34.0% and basophilic stipplings were found in peripheral blood smear. Chest PA was normal and abdominal ultrasonographic finding was non-specific except fatty liver. In the test of lead exposure indices, $PbB:83.0{\mu}g/dl,\;PbU:28.3{\mu}g/l$, and blood ZPP was $300.0{\mu}g/dl$. And in renal function test, BUN : 31.4 mg/dl, blood creatinine : 2.7mg/dl, blood uric acid. 9.1 mg/dl, urinary albumin : 100.0 mg/g creatinine, urinary $\alpha_1-microglobulin$ : 120.5 mg/g creatinine, urinary $\beta_2-microglobulin$ : $183.8{\mu}g/g$ creatinine, and 24 hours urinary creatinine clearance was 31.9 ml/min. The ultrasonoguided renal biopsy showed the global sclerosis of glomerulus, moderate atrophy and loss of tubule, and interstitial fibrosis in light microscopy. There were diffuse losses of brush border of proximal tubule in electronmicroscopy.

  • PDF

Two Cases of IgG-associated Mesangial Glomerulonephritis in Children (소아에서 관찰된 IgG-associated mesangial glomerulonephritis 2례)

  • Lee, Sang-Hoo;Kim, Pyung-Kil;Song, Ji-Sun
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • Rare cases of IgG associated mesangial glomerulonephritis(IgG GN) defined by exclusive or predominant mesangial IgG deposits were reported first by Sato et al.(1993). and subsequently 10 pediatric cases were reported by Yoshikawa et al.(1994). Previous reports suggested that the prognosis of IgG GN is relatively benign course but recent report suggested that prognosis of IgG GN is highly variable. Also the recurrence of IgG GN in a renal transplant was reported by Fakhouri et al. (2002). Such a recurrence highlights the specificity of this type of glomerulonephritis. We experienced two pediatric cases of IgG GN proven by renal biopsy. Case 1. 4-year-old girl with nephrotic syndrome admitted because of general edema. The patient's urinalysis showed proteinuria and microscopic hematuria. Renal biopsy was performed because of relapsed nephritic syndrome. Light microscopic finding was nonspecific with almost normal histology. Immunofluorescent findings showed diffuse segmental IgG(+) and IgM(+) deposits in the capillary walls, and focal segmental spotty C4(trace), C1q(trace) deposits. Electron microscopic findings showed focal portion of mesangial electron dense deposits without mesangial widening. Case 2. 11-year-old girl admitted for evaluation of microsopic hematuria detected through mass school urinary screening program. Renal biopsy was performed for exact diagnosis. Immunofluorescent findings showed focal segmental IgG(+), IgM(+/-) and C3(+/-) deposits. Electron microscopic findings showed focal portion of mesangial electron dense deposits without mesangial widening.

  • PDF

Effects of Anodic Voltages of Photcatalytic TiO2 and Doping in H2SO4 Solutions on the Photocatalytic Activity (광촉매 TiO2의 황산용액에서의 양극산화전압과 도핑이 광촉매 활성에 미치는 영향)

  • Lee, Seung-Hyun;Oh, Han-Jun;Chi, Choong-Soo
    • Korean Journal of Materials Research
    • /
    • v.22 no.8
    • /
    • pp.439-444
    • /
    • 2012
  • To compare the photocatalytic performances of titania for purification of waste water according to applied voltages and doping, $TiO_2$ films were prepared in a 1.0 M $H_2SO_4$ solution containing $NH_4F$ at different anodic voltages. Chemical bonding states of F-N-codoped $TiO_2$ were analyzed using surface X-ray photoelectron spectroscopy (XPS). The photocatalytic activity of the co-doped $TiO_2$ films was analyzed by the degradation of aniline blue solution. Nanotubes were formed with thicknesses of 200-300 nm for the films anodized at 30 V, but porous morphology was generated with pores of 1-2 ${\mu}m$ for the $TiO_2$ anodized at 180 V. The phenomenon of spark discharge was initiated at about 98 V due to the breakdown of the oxide films in both solutions. XPS analysis revealed the spectra of F1s at 684.3 eV and N1s at 399.8 eV for the $TiO_2$ anodized in the $H_2SO_4-NH_4F$ solution at 180 V, suggesting the incorporation of F and N species during anodization. Dye removal rates for the pure $TiO_2$ anodized at 30 V and 180 V were found to be 14.0% and 38.9%, respectively, in the photocatalytic degradation test of the aniline blue solution for 200 min irradiation; the rates for the F-N-codoped $TiO_2$ anodized at 30 V and 180 V were found to be 21.2% and 65.6%, respectively. From the results of diffuse reflectance absorption spectroscopy (DRS), it was found that the absorption edge of the F-N-codoped $TiO_2$ films shifted toward the visible light region up to 412 nm, indicating that the photocatalytic activity of $TiO_2$ is improved by appropriate doping of F and N by the addition of $NH_4F$.

Extragalactic Sciences from SPICA/FPC-S

  • Jeong, Woong-Seob;Matsumoto, Toshio;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Tsumura, Kohji;Tanaka, Masayuki;Shimonishi, Takashi;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Sung-Joon;Moon, Bongkon;Park, Kwijong;Park, Youngsik;Han, Wonyong;Nam, Ukwon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.36.2-36.2
    • /
    • 2013
  • The SPICA (SPace Infrared Telescope for Cosmology & Astrophysics) project is a next-generation infrared space telescope optimized for mid- and far-infrared observation with a cryogenically cooled 3m-class telescope. The focal plane instruments onboard SPICA will enable us to resolve many astronomical key issues from the formation and evolution of galaxies to the planetary formation. The FPC-S (Focal Plane Camera - Sciecne) is a near-infrared instrument proposed by Korea as an international collaboration. Owing to the capability of both low-resolution imaging spectroscopy and wide-band imaging with a field of view of $5^{\prime}{\times}5^{\prime}$, it has large throughput as well as high sensitivity for diffuse light compared with JWST. In order to strengthen advantages of the FPC-S, we propose the studies of probing population III stars by the measurement of cosmic near-infrared background radiation and the star formation history at high redshift by the discoveries of active star-forming galaxies. In addition to the major scientific targets, to survey large area opens a new parameter space to investigate the deep Universe. The good survey capability in the parallel imaging mode allows us to study the rare, bright objects such as quasars, bright star-forming galaxies in the early Universe as a way to understand the formation of the first objects in the Universe, and ultra-cool brown dwarfs. Observations in the warm mission will give us a unique chance to detect high-z supernovae, ices in young stellar objects (YSOs) even with low mass, the $3.3{\mu}$ feature of shocked circumstance in supernova remnants. Here, we report the current status of SPICA/FPC project and its extragalactic sciences.

  • PDF

Effects of DC Biases and Post-CMP Cleaning Solution Concentrations on the Cu Film Corrosion

  • Lee, Yong-K.;Lee, Kang-Soo
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.276-280
    • /
    • 2010
  • Copper(Cu) as an interconnecting metal layer can replace aluminum (Al) in IC fabrication since Cu has low electrical resistivity, showing high immunity to electromigration compared to Al. However, it is very difficult for copper to be patterned by the dry etching processes. The chemical mechanical polishing (CMP) process has been introduced and widely used as the mainstream patterning technique for Cu in the fabrication of deep submicron integrated circuits in light of its capability to reduce surface roughness. But this process leaves a large amount of residues on the wafer surface, which must be removed by the post-CMP cleaning processes. Copper corrosion is one of the critical issues for the copper metallization process. Thus, in order to understand the copper corrosion problems in post-CMP cleaning solutions and study the effects of DC biases and post-CMP cleaning solution concentrations on the Cu film, a constant voltage was supplied at various concentrations, and then the output currents were measured and recorded with time. Most of the cases, the current was steadily decreased (i.e. resistance was increased by the oxidation). In the lowest concentration case only, the current was steadily increased with the scarce fluctuations. The higher the constant supplied DC voltage values, the higher the initial output current and the saturated current values. However the time to be taken for it to be saturated was almost the same for all the DC supplied voltage values. It was indicated that the oxide formation was not dependent on the supplied voltage values and 1 V was more than enough to form the oxide. With applied voltages lower than 3 V combined with any concentration, the perforation through the oxide film rarely took place due to the insufficient driving force (voltage) and the copper oxidation ceased. However, with the voltage higher than 3 V, the copper ions were started to diffuse out through the oxide film and thus made pores to be formed on the oxide surface, causing the current to increase and a part of the exposed copper film inside the pores gets back to be oxidized and the rest of it was remained without any further oxidation, causing the current back to decrease a little bit. With increasing the applied DC bias value, the shorter time to be taken for copper ions to be diffused out through the copper oxide film. From the discussions above, it could be concluded that the oxide film was formed and grown by the copper ion diffusion first and then the reaction with any oxidant in the post-CMP cleaning solution.

The Development of the Simple SHGC Calculation Method in Case of a Exterior Venetian Blind Using the Simulation (시뮬레이션을 이용한 외부 베네시안 블라인드의 약식 SHGC 계산법 개발)

  • Eom, Jae-Yong;Lee, Chung-Kook;Jang, Weol-Sang;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.73-83
    • /
    • 2015
  • When it comes to these buildings for business use, cooling load during summertime was reported to have great importance which, as a result, impressively increased interest in Solar Heat Gain Coefficient (SHGC). Such SHGC is considered to be lowered with the help of colors and functions of glass itself, internal shading devices, insulation films and others but basically, these external shading devices for initial blocking that would not allow solar heat to come in from outside the buildings are determined to be most effective. Of many different external shading devices, this thesis conducted an analysis on Exterior Venetian Blind. As for vertical shading devices, previous researches already calculated SHGC conveniently using concepts of sky-opening ratios. However in terms of the Venetian Blind, such correlation is not possibly applied. In light of that, in order to extract a valid correlation, this study first introduced a concept called shape factor, which would use the breadth and a space of a shade, before carrying out the analysis. As a consequence, the concept helped this study to find a very similar correlation. Results of the analysis are summarized as follows. (1) Regarding SHGC depending on the surface reflectance of a shade, an average of 2% error is observed and yet, the figure can always be ignored when it comes to a simple calculation. (2) As for SHGC of each bearing, this study noticed deviations of 4% or less and in the end, it is confirmed that extraction can be achieved with no more than one correlation formula. (3) When only the shape factor and nothing else is used for finding a correlation formula, the formula with a deviation of approximately 5% or less is what one would expect. (4) Since the study observed slight differences in bearings depending on ranges of the shape factors, it needed to extract a weighted value of each bearing, and learned that the smaller the shape factor, the wider the range of a weighted value. The study now suggests that a follow-up research to extract a simple calculation formula by dealing with all these various inclined angles of shade, solar radiation conditions of each region (the ratio of diffuse radiation to direct radiation and others) as well as seasonal features should be carried out.

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

Developing of latent fingerprint on human skin (생체피부에서의 잠재지문 현출)

  • Lee, Hee-Il;Choi, Mi-Jung;Kim, Jai-Hoon;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • On living skin the chances of a successfully developing latent fingerprint are very limited. This is due to the fact that continual perspiration and rapid absorption diffuse into the lipophillic layer on skin. A study was conducted to investigate effectively developing method of latent fingerprints on human skin surfaces and pig skin likely corpse's skin. We used commercial fingerprint powder, black powders, black magnetic powder, fluorescence magnetic powder, Cyanoacrylate fuming (CA) and direct lifting methods (lifting paper, glasses and photo glossy paper). Developing of fresh fingerprints on living skin was achieved with S-powderblack, CA fuming and CA fuming following S-powder, fluorescence powder. The other powder tends to overwhelm the latent print and the background. But, latent fingerprint residue was disappeared with time after deposit on a living surface. In case of pig skin likely corpse's skin, latent fingerprint detection was achieved with CA fuming following S-powder and deposited print during 6 hr at $25^{\circ}C$, 40% relative moisture yielded excellent fingerprints with clear ridge details using 1 min CA fuming. And enhancement of fingerprint detection image using forensic light source was achieved.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF