• Title/Summary/Keyword: difficult factor

Search Result 1,385, Processing Time 0.027 seconds

Optimization of Artificial Neural Network Model in Scaling Factor Determination Method

  • Lee, Sang-Chul;Hwang, Ki-Ha;Kang, Sang-Hee;Lee, Kun-Jai
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.254-254
    • /
    • 2004
  • Final disposal of radioactive waste generated from Nuclear Power Plant (NPP) requires the detailed information about the characteristics and the quantities of radionuclides in waste package. Most radionuclides are difficult to measure and expensive to assay. Thus it is suggested to the indirect method by which the concentration of the Difficult-to-Measure (DTM) nuclide is estimated using the correlations of concentration-it is called the scaling factor-between Easy-to-Measure (Key) nuclides and DTM nuclides with the measured concentration of the Key nuclide.(omitted)

  • PDF

Calculation of Illuminance Using Fuzzy Reasoning and Zonal Cavity Method (퍼지 추론과 구역 공간법을 이용한 조도 계산법)

  • 최홍규;강태은;원진희;조용상
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.240-246
    • /
    • 1999
  • This parer proposes fuzzy reasoning algorithm for improvement in Zonal Cavity Method that is difficult to calculate average illumination without lighting scope and reflection factor so on. This parer use fuzzy reasoning algorithm for maintainment of the best illumination in spite of some variation those are influenced of room illumination and cut down the difficult to be calculated used Zonal Cavity Method.

  • PDF

Overestimation of Radioactivity Concentration of Difficult-To-Measure Radionuclides in Scaling Factor Methodology

  • Park, Junghwan;Kim, Tae-Hyeong;Lee, Jeongmook;Kim, Junhyuck;Kim, Jong-Yun;Lim, Sang Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.3
    • /
    • pp.367-386
    • /
    • 2021
  • The overestimation and underestimation of the radioactivity concentration of difficult-to-measure radionuclides can occur during the implementation of the scaling factor (SF) method because of the uncertainties associated with sampling, radiochemical analysis, and application of SFs. Strict regulations ensure that the SF method as an indirect method does not underestimate the radioactivity of nuclear wastes; however, there are no clear regulatory guidelines regarding the overestimation. This has been leading to the misuse of the SF methodology by stakeholders such as waste disposal licensees and regulatory bodies. Previous studies have reported instances of overestimation in statistical implementation of the SF methodology. The analysis of the two most popular linear models of the SF methodology showed that severe overestimation may occur and radioactivity concentration data must be dealt with care. Since one major source of overestimation is the use of minimum detectable activity (MDA) values as true activity values, a comparative study of instrumental techniques that could reduce the MDAs was also conducted. Thermal ionization mass spectrometry was recommended as a suitable candidate for the trace level analysis of long-lived beta-emitters such as iodine-129. Additionally, the current status of the United States and Korea was reviewed from the perspective of overestimation.

New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit (결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

The estimation of friction coefficient by using entropy theory in open channels (엔트로피 이론에 의한 개수로 마찰계수 산정)

  • Choo, Tai Ho;Kwak, Kil Sin;Yun, Gwan Seon;Yoon, Hyeon Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2868-2875
    • /
    • 2015
  • Both the friction velocity and the friction coefficient have to be estimated to determine flow characteristic in an open channel. In spite of the importances in an open channel, the complete interpretation is highly difficult because of free water surface, the complex of cross section and the various hydraulic parameters. The researches related to the friction factor are based on empirical outcome. Therefore, the equations are difficult to be generally applied. For that reason, the new friction factor estimation equation using the entropy concept was proposed in the present study, and the data measured in rectangular and trapezoid cross sections was used to verify the accuracy of equation. The advantage of the proposed equation dose not use the energy slope term which is difficult to be measured and to be estimated in an open channel. In addition, the proposed method showed that the accurate friction factor f can be estimated on the Basis of theoretical background.

Victory and Defeat Factor Analysis of Historic Battle using Simulation : Myeong-Ryang Sea-Battle during Japanese Invasion of Korea in 1592 (시뮬레이션을 이용한 역사적 전투사례의 승패요인 분석 : 임진왜란시 명량해전 사례 연구)

  • Cho, Sung-Jin
    • Korean Management Science Review
    • /
    • v.27 no.1
    • /
    • pp.61-73
    • /
    • 2010
  • Purpose of the War history's study is getting instruction by analyzing victory and defeat factor. This study is studied by qualitative form in war study mainly. In case recording literature is full, victory and defeat factor analysis is easy, but occasionally definite analysis that recording literature is feeble is difficult. Also, when it is battle result that escape common sense, about victory and defeat factor, various estimations are brought. As such example, there is Myeong-Ryang sea-battle at Japanese Invasion of Korea in 1592 and Korea(Cho-Sun) naval forces did big victory in 13 vs. 133 numerical inferiorities. This study presented method of study that using agent based simulation model for quantitative analysis of these victory and defeat factor.

Determination of Stress Intensity Factor $K_I$ from Two Fringe Orders by Fringe Multiplication and Sharpening

  • Chen, Lei;Baek, Tae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.550-555
    • /
    • 2007
  • Stress intensity factor is one of the most important parameters in fracture mechanics. Both the stress field distribution and the crack propagation are closely related to these parameters. Due to the complexity of actual engineering problems, it is difficult to calculate the stress intensity factor by theoretical formulation, so photoelasticity method is a good choice. In this paper, modified two parameter method is employed to calculate stress intensity factor for opening mode by using data from more than one photoelastic fringe loop. For getting accurate experiment results, the initial fringes are doubled and sharpened by digital image programs from the fringe patterns obtained by a CCD camera. Photoelastic results are compared with those obtained by the use of empirical equation and FEM. Good agreement shows that the methods utilized in experiments are considerably reliable. The photoelastic experiment can be used for bench mark in theoretical study and other experiments.

Anti-Tumor Necrosis Factor Therapy in Intestinal Behçet's Disease

  • Park, Jihye;Cheon, Jae Hee
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.623-632
    • /
    • 2018
  • Intestinal Behçet's disease is a rare, immune-mediated chronic intestinal inflammatory disease; therefore, clinical trials to optimize the management and treatment of patients are scarce. Moreover, intestinal Behçet's disease is difficult to treat and often requires surgery because of the failure of conventional medical treatment. Administration of anti-tumor necrosis factor-${\alpha}$, a potential therapeutic strategy, is currently under active clinical investigation, and evidence of its effectiveness for both intestinal Behçet's disease and inflammatory bowel diseases has been accumulating. Here, we review updated data on current experiences and outcomes after the administration of anti-tumor necrosis factor-${\alpha}$ for the treatment of intestinal Behçet's disease. In addition to infliximab and adalimumab, which are the most commonly used agents, we describe agents such as golimumab, etanercept, and certolizumab pegol, which have recently been shown to be effective in refractory intestinal Behçet's disease. This review also discusses safety issues associated with anti-tumor necrosis factor-${\alpha}$, including vulnerability to infections and malignancy.

Evaluation of the Response Modification Factor for RC Wall-type Structures (철근콘크리트 벽식 구조물의 반응수정계수 평가에 관한 연구)

  • 한상환;이리형;오영훈;천영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.433-438
    • /
    • 1998
  • Design lateral strength calculated by current seismic design code is prescribed to be much lower than the force level required for a structure to respond elastically during design level earthquake ground motion. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factor known as "response modification factor, R". This factor accounts for the inherent ductility, overstrength, redundancy, and damping of a structural system. This study considers ductility and overstrength of the wall-type structure for investigating R factor. This means that R factor is determined from the product of "ductility-based R factor($R_$\mu$$) and overstrength factor($R_s$). $R_$\mu$$ factor is calibrated to attain the targer ductility ratio (system ductility capacity) and produced in the from of $R_$\mu$$ spectra considering the influence of target ductility, natural period, and hysteretic model. On the other hand, $R_s$ is more difficult to quantify, since it depends on both material and system-dependent uncertain parameters. In this study Rs factor was determined from the result of push-over analysis.-over analysis.

  • PDF

Etiological risk factors of peri-implantitis : a literature review (임상가를 위한 특집 2 - 임플란트 주위염의 병인론적 위험요소에 대한 문헌적 고찰)

  • Hwang, Jae Ho
    • The Journal of the Korean dental association
    • /
    • v.51 no.12
    • /
    • pp.637-642
    • /
    • 2013
  • Because the implant is regarded as a common treatment. It is clinically important that systemic and local risk factor of threatening peri implant mucosa should be considered during the process. The most risk factors are detected in clinical diagnosis, but it might be difficult and not clear to recognize systemic or combined factors. This article reviews risk factors of peri-implantitis. Local factors are biomechanics, periodontal soft tissue characteristics, infected site and oral hygiene. Systemic factors are alcohol, smoking and genetic traits.