• Title/Summary/Keyword: differential image

Search Result 598, Processing Time 0.029 seconds

A wavelet-based fast motion estimation (웨이블릿 기반의 고속 움직임 예측 기법)

  • 배진우;선동우;유지상
    • Journal of Broadcast Engineering
    • /
    • v.8 no.3
    • /
    • pp.297-305
    • /
    • 2003
  • In this paper, we propose a wavelet based fast motion estimation algorithm for video sequence encoding with very low bit-rate. By using one of properties oi wavelet transform, multi-resolution analysis(MRA) property and spatial Interpolation of an image, we are able to reduce both prediction error and computational complexity at the same time. Especially, by defining a significant block(SB) based on the differential information of wavelet coefficients between successive frames, the proposed algorithm makes up a defect of multi-resolution motion estimation(MRME) algorithm of increasing the number of motion vectors. As experimental results. we can reduce the computational load up to 70% but also improve PSNR up to about 0.1 ∼ 1.2 dB comparing with the MRME algorithm.

Computer Tomography and Magnetic Resonance Image Manifestations of Primary Hepatic Neuroendocrine Cell Carcinomas

  • Huang, Juan;Yu, Jian-Qun;Sun, Jia-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2759-2764
    • /
    • 2014
  • Aim: This study aims to investigate the manifestation of CT, MRI and dynamic enhanced scans for primary hepatic neuroendocrine cell carcinoma. Methods: CT or MRI arterial and venous phase scan images of 19 cases of pathologically confirmed PHNEC were retrospectively analyzed. Results: 14 cases (73.68%) with single lesion, 5 cases (26.3%) with multiple lesions, with an average diameter of 13.2 cm. Some 12 cases (63.16%) showed inhomogeneous enhancement, seven cases (36.8%) showed homogeneous enhancement, 13 cases (68.4%) demonstrated significant enhancement in the arterial phase, 13 cases (68.4%) had significantly enhanced portal venous phase including 7 cases (36.8 %) with portal venous phase density or signal above the arterial phase and 5 cases (26.3%) with the portal vein density or signal below the arterial phase. Seven cases (36.8%) had continued strengthened separate shadows in the center of the lesion. Thrombosis were not seen in portal veins. Conclusion: CT and MRI images of liver cell neuroendocrine carcinoma have certain characteristics that can provide valuable information for diagnosis and differential diagnosis.

Fuzzy PID Control of Warranty Claims Time Series (보증 클레임 시계열 데이터를 위한 퍼지 PID 제어)

  • Lee, Sang-Hyun;Lee, Sang-Joon;Moon, Kyung-Il;Cho, Sung-Eui
    • Journal of Information Technology Services
    • /
    • v.8 no.4
    • /
    • pp.175-185
    • /
    • 2009
  • Objectifying claims filed during the warranty period, analyzing the current circumstances and improving on the problem in question is an activity worth doing that could reduce the likelihood of claims to occur, cut down on the costs, and enhance the corporate image of the manufacturer. Existing analyses of claims are confronted with two problems. First, you can't precisely assess the risks of claims involved by means of the value of claims per 100 products alone. Second, even in a normal state, the existing approach fails to capture the probabilistic conflicts that escape the upper control limit of claims, thus leading to wrong control activities. To solve the first problem, this paper proposed that a time series detection concept where the claim rate is monitored based on the date when problems are processed and a hazard function for expression of the claim rate be utilized. For the second problem, this paper designed a model whereby to define a normal state by making use of PID (Proportion, Integral, Differential) and infer by way of a fuzzy concept. This paper confirmed the validity and applicability of the proposed approach by applying methods suggested in the actual past data of warranty claims of a large-scaled automotive firm, unlike hypothetical simulation data, in order to apply them directly in industrial job sites, as well as making theoretical suggestions for analysis of claims.

Adaptive Video Coding by Wavelet Transform (웨이브렛 변환에 의한 적응적 동영상 부호화)

  • 김정일;김병천
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.2
    • /
    • pp.141-146
    • /
    • 1999
  • In this paper, picture set filter is proposed for preserving compression ratio and video qualify. This filter controls the compression ratio of each frame depending on the correlation to the reference frame by selectively eliminating less important high-resolution areas. Consequently, video quality can be preserved and bit rate can be controlled adaptively. In the simulation, to test the performance of the proposed coding method, comparisons with the full search block matching algorithm and the differential image coding algorithm are made. In the former case, video quality, compression ratio and encoding time is improved. In the latter case, video quality is degraded, but compression ratio and encoding time is improved. Consequently. the proposed method shows a reasonably good performance over existing ones.

  • PDF

Embedding a Signature to Pictures under Wavelet Transformation (웨이브렛변환을 이용한 영상으로의 서명데이터 삽입)

  • Do, Jae-Su
    • Convergence Security Journal
    • /
    • v.7 no.1
    • /
    • pp.83-89
    • /
    • 2007
  • This paper is to suggest the method of embedding a signature to pictures secretly under the orthogonal wavelet transform which represents pictures as multi-resolution representations. As it is focused upon the differential output under the multi-resolution representation of pictures, this method can embed bit series to pictures. In doing so, it can compound approximately 6K byte of information with gray-level image $256{\times}256$. The method can include not only the database which designates copyright of pictures but also the author and usage of pictures, and the information of the picture itself. Therefore, this method can easily discriminate the inspection of picture database.

  • PDF

Auto-guiding System for CQUEAN

  • Kim, Eun-Bin;Park, Won-Kee;Jeong, Hyeon-Ju;Kim, Jin-Young;Kim, Dong-Han;Kim, Han-Guen;Kuehne, John;Odoms, Peter S.;Choi, Chang-Su;Im, Myung-Shin;Pak, Soo-Jong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.61.2-61.2
    • /
    • 2010
  • CQUEAN (Camera for Quasars in EArly uNiverse) is an optical CCD camera system which has its own auto-guiding system. Guiding system consists of a 1k*1k CCD camera, FLI PL1001E, a flat mirror to feed the image of an off-axis field to the camera and baffle. The whole system lies on a moving arm which rotates 90 degree effectively to enlarge the field of view. A motor, IMS MDRIVE 34, and a differential decelerator, APEX AD140-050, are used for the moving mechanism. Auto-guiding is controlled by Agdr program. We had a first light from Aug. 10 to Aug 17, 2010 at McDonald Observatory, USA. In this presentation, we describe about the auto-guiding system for CQUEAN and its performance on the 2.1m telescope.

  • PDF

CUDA based Lossless Asynchronous Compression of Ultra High Definition Game Scenes using DPCM-GR (DPCM-GR 방식을 이용한 CUDA 기반 초고해상도 게임 영상 무손실 비동기 압축)

  • Kim, Youngsik
    • Journal of Korea Game Society
    • /
    • v.14 no.6
    • /
    • pp.59-68
    • /
    • 2014
  • Memory bandwidth requirements of UHD (Ultra High Definition $4096{\times}2160$) game scenes have been much more increasing. This paper presents a lossless DPCM-GR based compression algorithm using CUDA for solving the memory bandwidth problem without sacrificing image quality, which is modified from DDPCM-GR [4] to support bit parallel pipelining. The memory bandwidth efficiency increases because of using the shared memory of CUDA. Various asynchronous transfer configurations which can overlap the kernel execution and data transfer between host and CUDA are implemented with the page-locked host memory. Experimental results show that the maximum 31.3 speedup is obtained according to CPU time. The maximum 30.3% decreases in the computation time among various configurations.

Effects of Particle Shapes on Unipolar Diffusion Charging of Non-Spherical Particles (비구형 입자의 형상에 따른 단극 확산 하전 특성)

  • Oh, Hyun-Cheol;Park, Hyung-Ho;Kim, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.501-509
    • /
    • 2004
  • Unipolar diffusion charging of non-spherical particles was investigated for various particle shapes. We researched with TiO$_2$agglomerates produced by the thermal decomposition of titanium tetraisopropoxide (TTIP) vapor. TTIP was converted into TiO$_2$, in the furnace reactor and was subsequently introduced into the sintering furnace. Increasing the temperature in the sintering furnace, aggregates were restructured into higher fractal dimensions. The aggregates were classified according to their mobility using a differential mobility analyzer. The projection area and the mass fractal dimension of particles were measured with an image processing technique performed by using transmission electron microscope (TEM) photograph. The selected aggregates were charged by the indirect photoelectric-charger and the average number of charges per particle was measured by an aerosol electrometer and a condensation particle counter. For the particles of same mobility diameter, our results showed that the particle charge quantity decreases as the sintering temperature increases. This result is understandable because particles with lower fractal dimension have larger capacitance and geometric surface area.

PSE (pale, soft, exudative) Pork : The Causes and Solutions - Review -

  • Lee, Y.B.;Choi, Y.I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.2
    • /
    • pp.244-252
    • /
    • 1999
  • Intensive selection for muscle development and against fat deposition in pigs during the last 50 years has contributed to the increased incidence of porcine stress syndrome (PSS) and pale soft exudative pork (PSE). Genetics, nutrition and management, preslaughter animal handling, stunning, dehairing and carcass chilling influence the incidence and magnitude of the PSE condition. The normal incidence of PSE has been reported to range from 10 to 30%, but in some isolated instances is up to 60%. The elimination of halothane-positive pigs in breeding programs has reduced PSS and PSE. Further improvements in meat quality by terminal sire evaluation and selection can be achieved within halothane-negative populations because around 20% of the variation in meat color and water binding capacity seems to be genetically related. Pre-slaughter handling on the farm, during transit to the packing plant and at the packing plant can greatly influence the meat quality, contributing 10 to 25% of the variation. An effective stunning method, skinning instead of scalding/dehairing and rapid post-slaughter chilling further reduce the incidence of PSE pork. In addition to proper care and handling a carcass-merit based marketing system, that reflected the value differential between desirable and undesirable meat quality in the pricing system for pigs, would provide a great incentive to change pork production systems in order to improve meat quality, thus improving the image and usefulness of pork as food.

Non-Traumatic Myositis Ossificans in the Lumbosacral Paravertebral Muscle

  • Jung, DaeYoung;Cho, Keun-Tae;Roh, Ji Hyeon
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.5
    • /
    • pp.305-308
    • /
    • 2013
  • Myositis ossificans (MO) is a benign condition of non-neoplastic heterotopic bone formation in the muscle or soft tissue. Trauma plays a role in the development of MO, thus, non-traumatic MO is very rare. Although MO may occur anywhere in the body, it is rarely seen in the lumbosacral paravertebral muscle (PVM). Herein, we report a case of non-traumatic MO in the lumbosacral PVM. A 42-year-old man with no history of trauma was referred to our hospital for pain in the low back, left buttock, and left thigh. On physical examination, a slightly tender, hard, and fixed mass was palpated in the left lumbosacral PVM. Computed tomography showed a calcified mass within the left lumbosacral PVM. Magnetic resonance imaging (MRI) showed heterogeneous high signal intensity in T1- and T2-weighted image, and no enhancement of the mass was found in the postcontrast T1-weighted MRI. The lack of typical imaging features required an open biopsy, and MO was confirmed. MO should be considered in the differential diagnosis when the imaging findings show a mass involving PVM. When it is difficult to distinguish MO from soft tissue or bone malignancy by radiology, it is necessary to perform a biopsy to confirm the diagnosis.