• Title/Summary/Keyword: differential coefficient

Search Result 456, Processing Time 0.027 seconds

A review of effects of partial dynamic loading on dynamic response of nonlocal functionally graded material beams

  • Ahmed, Ridha A.;Fenjan, Raad M.;Hamad, Luay Badr;Faleh, Nadhim M.
    • Advances in materials Research
    • /
    • v.9 no.1
    • /
    • pp.33-48
    • /
    • 2020
  • With the use of differential quadrature method (DQM), forced vibrations and resonance frequency analysis of functionally graded (FG) nano-size beams rested on elastic substrate have been studied utilizing a shear deformation refined beam theory which contains shear deformations influence needless of any correction coefficient. The nano-size beam is exposed to uniformly-type dynamical loads having partial length. The two parameters elastic substrate is consist of linear springs as well as shear coefficient. Gradation of each material property for nano-size beam has been defined in the context of Mori-Tanaka scheme. Governing equations for embedded refined FG nano-size beams exposed to dynamical load have been achieved by utilizing Eringen's nonlocal differential law and Hamilton's rule. Derived equations have solved via DQM based on simply supported-simply supported edge condition. It will be shown that forced vibrations properties and resonance frequency of embedded FG nano-size beam are prominently affected by material gradation, nonlocal field, substrate coefficients and load factors.

Mechanical-hygro-thermal vibrations of functionally graded porous plates with nonlocal and strain gradient effects

  • Fenjan, Raad M.;Hamad, Luay Badr;Faleh, Nadhim M.
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.2
    • /
    • pp.169-186
    • /
    • 2020
  • Based upon differential quadrature method (DQM) and nonlocal strain gradient theory (NSGT), mechanical-hygro-thermal vibrational analyzes of shear deformable porous functionally graded (FG) nanoplate on visco-elastic medium has been performed. The presented formulation incorporates two scale factors for examining vibrational behaviors of nano-dimension plates more accurately. The material properties for FG plate are porosity-dependent and defined employing a modified power-law form. It is supposed that the nano-size plate is exposed to hygro-thermal and variable compressive mechanical loadings. The governing equations achieved by Hamilton's principle are solved implementing DQM. Presented results indicate the prominence of moisture/temperature variation, damping factor, material gradient index, nonlocal coefficient, strain gradient coefficient and porosities on vibrational frequencies of FG nano-size plate.

Semi-numerical simulation for effects of different loadings on vibration behavior of 2D systems

  • Rao, Li;Lin, Chao;Zhang, Chenglin
    • Structural Engineering and Mechanics
    • /
    • v.81 no.3
    • /
    • pp.259-266
    • /
    • 2022
  • Based upon differential quadrature method (DQM) and nonlocal strain gradient theory (NSGT), an investigation on the free vibrations of 2D plate systems with nano-dimensions has been provided taking into account the effects of different mechanical loadings. In order to capture different mechanical loadings, a general form of variable compressive load applied in the axial direction of the plate system has been introduced. The studied plate has been constructed from two types of particles which results in graded material properties and nanoscale pores. The established formulation for the plate is in the context of a novel shear deformable model and the equations have been solved via a semi-numerical trend. Presented results indicate the prominence of material composition, nonlocal coefficient, strain gradient coefficient and boundary conditions on vibrational frequencies of nano-size plate.

The existence of the fuzzy solutions for the differential system with fuzzy coefficient (퍼지 계수를 갖는 미분 시스템에 대한 퍼지 해의 존재성)

  • K.D. Son;J.R. Kang;Lee, B.Y.;Park, Y.B
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.353-356
    • /
    • 2001
  • In this paper, we study the existence of fuzzy solution for the following differential system with fuzzy coefficient using the different two methods: (equation omitted), where a, b is the fuzzy natural number generated by fuzzy number l . The a-level set of the fuzzy number (equation omitted). The -level set of a is (equation omitted) and -level set of b is (equation omitted).

  • PDF

SORET AND ELECTROMAGNETIC RADIATION EFFECT OF MHD MICRO POLAR FLUID PAST A POROUS MEDIUM IN THE PRESENCE OF CHEMICAL REACTION

  • SHEEBA JULIET S.;VIDHYA, M.
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.5
    • /
    • pp.1085-1102
    • /
    • 2023
  • In this study the magneto hydrodynamic (MHD) micro polar fluid flow of a viscous incompressible fluid past a porous medium in the presence of chemical reaction is considered. This work is devoted to investigate the Soret effect and Electromagnetic radiation effect and analyze analytically. In the energy equation the applied magnetic field strength and in the concentration equation the Soret effect are incorporated. The basic PDE (partial differential equations) are reduced to ODE (ordinary differential equations) using non dimensional variables. Then the analytical solution of the dimensionless equations are found using perturbation technique. The features of the fluid flow parameters are analyzed, discussed and explained graphically. The graphical solutions are found using MATLAB R2019b. Skin friction coefficient at the wall, Couple stress coefficient at the plate and the local surface heat flux are also thoroughly examined. Overall, this study sheds light on the complex interplay between physical parameters in the behavior of MHD micro-polar fluid past a porous medium in the presence of chemical reaction.

CAPUTO DELAYED FRACTIONAL DIFFERENTIAL EQUATIONS BY SADIK TRANSFORM

  • Awad T. Alabdala;Basim N. Abood;Saleh S. Redhwan;Soliman Alkhatib
    • Nonlinear Functional Analysis and Applications
    • /
    • v.28 no.2
    • /
    • pp.439-448
    • /
    • 2023
  • In this article, we are interested in studying the fractional Sadik Transform and a combination of the method of steps that will be applied together to find accurate solutions or approximations to homogeneous and non-homogeneous delayed fractional differential equations with constant-coefficient and possible extension to time-dependent delays. The results show that the process is correct, exact, and easy to do for solving delayed fractional differential equations near the origin. Finally, we provide several examples to illustrate the applicability of this method.

Squeezing Flow of Micropolar Nanofluid between Parallel Disks

  • Khan, Sheikh Irfanullah;Mohyud-Din, Syed Tauseef;Yang, Xiao-Jun
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.476-489
    • /
    • 2016
  • In the present study, squeezing flow of micropolar nanofluid between parallel infinite disks in the presence of magnetic field perpendicular to plane of the disks is taken into account. The constitutive equations that govern the flow configuration are converted into nonlinear ordinary differential with the help of suitable similarity transforms. HAM package BVPh2.0 has been employed to solve the nonlinear system of ordinary differential equations. Effects of different emerging parameters like micropolar parameter K, squeezed Reynolds number R, Hartmann number M, Brownian motion parameter Nb, thermophoresis parameter Nt, Lewis number Le for dimensionless velocities, temperature distribution and concentration profile are also discussed graphically. In the presence of strong and weak interaction (i.e. n = 0 and n = 0.5), numerical values of skin friction coefficient, wall stress coefficient, local Nusselt number and local Sherwood number are presented in tabulated form. To check the validity and reliability of the developed algorithm BVPh2.0 a numerical investigation is also a part of this study.

Efficient Noise Estimation for Speech Enhancement in Wavelet Packet Transform

  • Jung, Sung-Il;Yang, Sung-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4E
    • /
    • pp.154-158
    • /
    • 2006
  • In this paper, we suggest a noise estimation method for speech enhancement in nonstationary noisy environments. The proposed method consists of the following two main processes. First, in order to receive fewer affect of variable signals, a best fitting regression line is used, which is obtained by applying a least squares method to coefficient magnitudes in a node with a uniform wavelet packet transform. Next, in order to update the noise estimation efficiently, a differential forgetting factor and a correlation coefficient per subband are used, where subband is employed for applying the weighted value according to the change of signals. In particular, this method has the ability to update the noise estimation by using the estimated noise at the previous frame only, without utilizing the statistical information of long past frames and explicit nonspeech frames by voice activity detector. In objective assessments, it was observed that the performance of the proposed method was better than that of the compared (minima controlled recursive averaging, weighted average) methods. Furthermore, the method showed a reliable result even at low SNR.

A Study on the Flow Coefficient Test and Numerical Analysis about 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump (보일러 급수펌프용 1500lb 고차압 제어밸브 유량시험 및 수치해석에 관한 연구)

  • Lee, Kwon-Il;Jang, Hoon;Lee, Chi-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.541-547
    • /
    • 2022
  • Before making a prototype, we predicted the inlet/outlet differential pressure and flow coefficient, which are the most basic design data for the valve through the design and numerical analysis of the trim, which is the most important in the localization development of the 1500Ib high differential pressure control valve used for boiler feed water. As a result, the design value and the analysis value were found to be about 98% similar. The flow field within the fluid velocity of 23m/s to prevent cavitation was also found. The result of the numerical analysis on thermal stress due to the characteristics of valves exposed to high temperatures showed that it was found to be about 18% less than the allowable stress of the bolt fixing the trim. When all loads such as pressure, self-weight, and vibration are applied, however, it is judged to go beyond the currently calculated thermal stress, exceeding the allowable stress.

Evaluation of Coulter® LH 750TM on Leukocyte Differential Count and Suspect Flags (Coulter® LH 750TM에 의한 백혈구 감별계산 및 Suspect Flags의 평가)

  • Hong, Seung-Bok;Choi, Jong-Tae;Lee, Seong-Kyu;Kim, Hyun-Soo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2005
  • Automatic hematology analyzers provide the leukocyte differential count and the useful flags of the various hematological parameters. We compared LH 750 (Beckman Coulter Co., Miami, FL, USA) with manual method on differential leukocyte counts and evaluated the usefulness of the suspect flags, provided by this instrument. The comparison of leukocyte differential counts between two methods showed good correlation coefficient (r), which were 0.95 (neutrophil), 0.92 (lymphocyte), 0.82 (monocyte) and 0.95 (eosinophil). The frequency of the total flags displayed on LH 750 were 15.5%, which included immature granulocyte/left shift 63.5%, nucleated RBC 14.6%, platelet clumps 13.1%, variant lymphocyte 50% and blast 16.6%. This instrument showed higher positive predictive value in the flags such as platelet clumps 68.8%, immature granulocyte/left shift 61.5%, nucleated RBC 27.3%, variant lymphocyte 50% and blast 16.7%. In this study, the leukocyte differential counts of LH 750 showed good correlation with manual method and the suspect flags also showed a good performance for applying the criteria of re-examination in the clinical laboratory.

  • PDF