• Title/Summary/Keyword: differential coefficient

Search Result 456, Processing Time 0.026 seconds

Studies of Solid-Liquid Phase Equilibria for Mixtures of N-vinyl-2-pyrrolidone+2-pyrrolidone and Growth Rate of N-vinyl-2-pyrrolidone Crystal Using Melt Crystallization (N-vinyl-2-pyrrolidone과 2-pyrrolidone 혼합물의 고-액 상평형 및 용융결정화를 이용한 N-vinyl-2-pyrrolidone의 결정성장속도 연구)

  • Kim, Sun Hyung;Seo, Myoung Do;Tak, Moon Seon;Kim, Woo Sik;Yang, Dae Ryuk;Kang, Jeong Won
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.587-590
    • /
    • 2013
  • Solid-liquid equilibria for mixtures composed of n-vinyl-2-pyrrolidone (NVP) and 2-pyrrolidone were measured as a basic study for the melt crystallization process to remove 2-pyrrolidone as impurity included in NVP. A differential scanning calorimeter (DSC) and a crystallizer were used and the experimental results obtained from two methods were similar. The mixture showed a eutectic system which has a single composition at the minimum melting temperature. Calculation results from simple thermodynamic equations were found in general agreements with present data. To determine the growth rate of NVP crystal which is important for the design of crystallization process, thicknesses of the crystal were measured with the time using a layer melt crystallizer. The growth rates increased as cooling temperatures decreased. Heat transfer coefficient correlated from present data was found to successfully describe the crystal growth behavior.

Anodic Stripping Voltammetric Determinations of Zinc, Cadmium, Lead and Copper in Freshwater and Sediment (담수 및 퇴적물에 함유된 아연, 카드뮴, 납 및 구리의 산화전극 벗김 전압전류법 정량)

  • Hahn, Young Hee;Yoo, Jeong Yeon
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.4
    • /
    • pp.180-185
    • /
    • 1997
  • Zinc, cadmium, lead and copper were simultaneously determined by depositing metals at - 1.200 V vs. a Ag/AgCl(sat. KCl) reference electrode for 150 seconds on a hanging mercury drop electrode(HMDE) or a thin mercury film electrode(TMFE), followed by scanning towards anodic direction using differential pulse voltammetric(DPASV) and square wave voltammetric(SWASV) techniques. The linear calibration curves were obtained for four metal ions simultaneously determined by DPASV with a HMDE in the concentration range between 20 and 100 ppb. However, the linear calibration plots were obtained only for $Cd^{2+}$ and $Pb^{2+}$ in the simultaneous determinations with a TMFE in the concentration range up to 100 ppb using DPASV and up to 10 ppb using SWASV. DPASV with a TMFE was about 15 times more sensitive than DPASV with a HMDE for simultaneous determinations of $Cd^{2+}$ and $Pb^{2+}$. SWASV was about 5 times more sensitive than DPASV at a TMFE. Concentrations of zinc in seven different sediment samples determined by DPASV with a HMDE and inductively coupled plasma-mass spectrometry were compared, resulting with an excellent correlation coefficient of 0.9993 and with no significant difference between two methods after t-test.

  • PDF

Development of Fracture Energy Measurement System of Asphalt Mixture Using Marshall Tester (마샬 안정도시험기를 이용한 아스팔트 혼합물의 파괴에너지 측정시스템 개발)

  • Kim, Boo-Il;Lee, Moon-Sup
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.135-144
    • /
    • 2009
  • The purpose of this study is to develop a simple and rational crack evaluation system using Marshall tester. Fracture energy were used as a parameter to evaluate the crack resistance of asphalt mixtures. Marshall tester basically measures the vertical deformation obtained from the linear variable differential transformer(LVDT) attached on the specimen's exterior, which can cause a measurement error due to the local deformation near the loading head. Therefore, the validity of the measurement system of Marshall tester should be tested to use it in calculation of fracture energy. Two types of indirect tensile strength tests were performed using four types of asphalt mixtures at two temperature conditions. From the tests, it was shown that local deformation near the loading head had not occurred before a specimen was fractured, so that it did not cause the measurement error of fracture energy. And also from the statistic analysis, the coefficient of variation of vertical deformation measurements obtained on specimen's exterior is less than 15%. Thus, vertical deformation measurements obtained on the specimen's exterior can be used in crack evaluation system using Marshall tester.

  • PDF

Modeling of flat otter boards motion in three dimensional space (평판형 전개판의 3차원 운동 모델링)

  • Choe, Moo-Youl;Lee, Chun-Woo;Lee, Gun-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.1
    • /
    • pp.49-61
    • /
    • 2007
  • Otter boards in the trawl are the one of essential equipments for the net mouth to be spread to the horizontal direction. Its performance should be considered in the light of the spreading force to the drag and the stability of towing in the water. Up to the present, studies of the otter boards have focused mainly on the drag and lift force, but not on the stability of otter boards movement in 3 dimensional space. In this study, the otter board is regarded as a rigid body, which has six degrees of freedom motion in three dimensional coordinate system. The forces acting on the otter boards are the underwater weight, the resistance of drag and spread forces and the tension on the warps and otter pendants. The equations of forces were derived and substituted into the governing equations of 6 degrees of freedom motion, then the second order of differential equations to the otter boards were established. For the stable numerical integration of this system, Backward Euler one of implicit methods was used. From the results of the numerical calculation, graphic simulation was carried out. The simulations were conducted for 3 types of otter boards having same area with different aspect ratio(${\lambda}=0.5,\;1.0,\;1.5$). The tested gear was mid-water trawl and the towing speed was 4k't. The length of warp was 350m and all conditions were same to each otter board. The results of this study are like this; First, the otter boards of ${\lambda}=1.0$ showed the longest spread distance, and the ${\lambda}=0.5$ showed the shorted spread distance. Second, the otter boards of ${\lambda}=1.0$ and 1.5 showed the upright at the towing speed of 4k't, but the one of ${\lambda}=0.5$ heeled outside. Third, the yawing angles of three otter boards were similar after 100 seconds with the small oscillation. Fourth, it was revealed that the net height and width are affected by the characteristics of otter boards such as the lift coefficient.

Performance Improvement Method of Deep Neural Network Using Parametric Activation Functions (파라메트릭 활성함수를 이용한 심층신경망의 성능향상 방법)

  • Kong, Nayoung;Ko, Sunwoo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.616-625
    • /
    • 2021
  • Deep neural networks are an approximation method that approximates an arbitrary function to a linear model and then repeats additional approximation using a nonlinear active function. In this process, the method of evaluating the performance of approximation uses the loss function. Existing in-depth learning methods implement approximation that takes into account loss functions in the linear approximation process, but non-linear approximation phases that use active functions use non-linear transformation that is not related to reduction of loss functions of loss. This study proposes parametric activation functions that introduce scale parameters that can change the scale of activation functions and location parameters that can change the location of activation functions. By introducing parametric activation functions based on scale and location parameters, the performance of nonlinear approximation using activation functions can be improved. The scale and location parameters in each hidden layer can improve the performance of the deep neural network by determining parameters that minimize the loss function value through the learning process using the primary differential coefficient of the loss function for the parameters in the backpropagation. Through MNIST classification problems and XOR problems, parametric activation functions have been found to have superior performance over existing activation functions.

Quantitative precipitation estimation of X-band radar using empirical relationship (경험적 관계식을 이용한 X밴드 레이더의 정량적 강우 추정)

  • Song, Jae In;Lim, Sanghun;Cho, Yo Han;Jeong, Hyeon Gyo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.9
    • /
    • pp.679-686
    • /
    • 2022
  • As the occurrences of flash floods have increased due to climate change, faster and more accurate precipitation observation using X-band radar has become important. Therefore, the Ministry of Environment installed two dual-pol X-band radars at Samcheok and Uljin. The radar data used in this study were obtained from two different elevation angles and composed to reduce the shielding effect. To obtain quantitative rainfall, quality control (QC), KDP retrieval, and Hybrid Surface Rainfall (HSR) methods were sequentially applied. To improve the accuracy of the quantitative precipitation estimation (QPE) of the X-band radar, we retrieved parameters for the relationship between rainfall rate and specific differential phase, which is commonly called the R-KDP relationship; hence, an empirical approach was developed using multiple rain gauges for those two radars. The newly suggested relationship, R = 27.4K0.81DP, slightly increased the correlation coefficient by 1% more than the relationship suggested by the previous study. The root mean square error significantly decreased from 3.88 mm/hr to 3.68 mm/hr, and the bias of the estimated precipitation also decreased from -1.72 mm/hr to -0.92 mm/hr for overall cases, showing the improvement of the new method.

Clinical and Radiological Features of Diffuse Lacrimal Gland Enlargement: Comparisons among Various Etiologies in 91 Biopsy-Confirmed Patients

  • Sae Rom Chung;Gye Jung Kim;Young Jun Choi;Kyung-Ja Cho;Chong Hyun Suh;Soo Chin Kim;Jung Hwan Baek;Jeong Hyun Lee;Min Kyu Yang;Ho-Seok Sa
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.976-985
    • /
    • 2022
  • Objective: To compare the clinical and radiological features of various etiologies of chronic diffuse lacrimal gland enlargement. Materials and Methods: We retrospectively reviewed 91 consecutive patients who underwent surgical biopsy for chronic diffuse lacrimal gland enlargement and were diagnosed with non-specific dacryoadenitis (DA) (n = 42), immunoglobulin G4-related dacryoadenitis (IgG4-RD) (n = 33), and lymphoma (n = 16). Data on patient demographics, clinical presentation, and CT imaging findings (n = 73) and MRI (n = 43) were collected. The following radiologic features of lacrimal gland enlargement were evaluated: size, unilaterality, wedge sign, angle with the orbital wall, heterogeneity, signal intensity, degree of enhancement, patterns of dynamic contrast-enhanced, and apparent diffusion coefficient value. Radiological features outside the lacrimal glands, such as extra-lacrimal orbital involvement and extra-orbital head and neck involvement, were also evaluated. The clinical and radiological findings were compared among the three diseases. Results: Compared to the DA and IgG4-RD groups, the lymphoma group was significantly older (mean 59.9 vs. 46.0 and 49.4 years, respectively; p = 0.001) and had a higher frequency of unilateral involvement (62.5% vs. 31.0% and 15.2%, respectively; p = 0.004). Compared to the IgG4-RD and lymphoma groups, the DA group had significantly smaller lacrimal glands (2.3 vs. 2.8 and 3.3 cm, respectively; p < 0.001) and a lower proportion of cases with a wedge sign (54.8% vs. 84.8% and 87.5%, respectively; p = 0.005). The IgG4-RD group showed more frequent involvement of the extra-orbital head and neck structures, including the infraorbital nerve (36.4%), paranasal sinus (72.7%), and salivary gland (58.6%) compared to the DA and lymphoma groups (4.8%-28.6%) (all p < 0.005). Conclusion: Patient age, unilaterality, lacrimal gland size, wedge sign, and extra-orbital head and neck involvement differed significantly different between lymphoma, DA, and IgG4-RD. Our results will be useful for the differential diagnosis and proper management of chronic lacrimal gland enlargement.

Comparison of One- and Two-Region of Interest Strain Elastography Measurements in the Differential Diagnosis of Breast Masses

  • Hee Jeong Park;Sun Mi Kim;Bo La Yun;Mijung Jang;Bohyoung Kim;Soo Hyun Lee;Hye Shin Ahn
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.431-441
    • /
    • 2020
  • Objective: To compare the diagnostic performance and interobserver variability of strain ratio obtained from one or two regions of interest (ROI) on breast elastography. Materials and Methods: From April to May 2016, 140 breast masses in 140 patients who underwent conventional ultrasonography (US) with strain elastography followed by US-guided biopsy were evaluated. Three experienced breast radiologists reviewed recorded US and elastography images, measured strain ratios, and categorized them according to the American College of Radiology breast imaging reporting and data system lexicon. Strain ratio was obtained using the 1-ROI method (one ROI drawn on the target mass), and the 2-ROI method (one ROI in the target mass and another in reference fat tissue). The diagnostic performance of the three radiologists among datasets and optimal cut-off values for strain ratios were evaluated. Interobserver variability of strain ratio for each ROI method was assessed using intraclass correlation coefficient values, Bland-Altman plots, and coefficients of variation. Results: Compared to US alone, US combined with the strain ratio measured using either ROI method significantly improved specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve (AUC) (all p values < 0.05). Strain ratio obtained using the 1-ROI method showed higher interobserver agreement between the three radiologists without a significant difference in AUC for differentiating breast cancer when the optimal strain ratio cut-off value was used, compared with the 2-ROI method (AUC: 0.788 vs. 0.783, 0.693 vs. 0.715, and 0.691 vs. 0.686, respectively, all p values > 0.05). Conclusion: Strain ratios obtained using the 1-ROI method showed higher interobserver agreement without a significant difference in AUC, compared to those obtained using the 2-ROI method. Considering that the 1-ROI method can reduce performers' efforts, it could have an important role in improving the diagnostic performance of breast US by enabling consistent management of breast lesions.

Differentiation of True Recurrence from Delayed Radiation Therapy-related Changes in Primary Brain Tumors Using Diffusion-weighted Imaging, Dynamic Susceptibility Contrast Perfusion Imaging, and Susceptibility-weighted Imaging (확산강조영상, 역동적조영관류영상, 자화율강조영상을 이용한 원발성 뇌종양환자에서의 종양재발과 지연성 방사선치료연관변화의 감별)

  • Kim, Dong Hyeon;Choi, Seung Hong;Ryoo, Inseon;Yoon, Tae Jin;Kim, Tae Min;Lee, Se-Hoon;Park, Chul-Kee;Kim, Ji-Hoon;Sohn, Chul-Ho;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.120-132
    • /
    • 2014
  • Purpose : To compare dynamic susceptibility contrast imaging, diffusion-weighted imaging, and susceptibility-weighted imaging (SWI) for the differentiation of tumor recurrence and delayed radiation therapy (RT)-related changes in patients treated with RT for primary brain tumors. Materials and Methods: We enrolled 24 patients treated with RT for various primary brain tumors, who showed newly appearing enhancing lesions more than one year after completion of RT on follow-up MRI. The enhancing-lesions were confirmed as recurrences (n=14) or RT-changes (n=10). We calculated the mean values of normalized cerebral blood volume (nCBV), apparent diffusion coefficient (ADC), and proportion of dark signal intensity on SWI (proSWI) for the enhancing-lesions. All the values between the two groups were compared using t-test. A multivariable logistic regression model was used to determine the best predictor of differential diagnosis. The cutoff value of the best predictor obtained from receiver-operating characteristic curve analysis was applied to calculate the sensitivity, specificity, and accuracy for the diagnosis. Results: The mean nCBV value was significantly higher in the recurrence group than in the RT-change group (P=.004), and the mean proSWI was significantly lower in the recurrence group (P<.001). However, no significant difference was observed in the mean ADC values between the two groups. A multivariable logistic regression analysis showed that proSWI was the only independent variable for the differentiation; the sensitivity, specificity, and accuracy were 78.6% (11 of 14), 100% (10 of 10), and 87.5% (21 of 24), respectively. Conclusion: The proSWI was the most promising parameter for the differentiation of newly developed enhancing-lesions more than one year after RT completion in brain tumor patients.

Unenhanced Breast MRI With Diffusion-Weighted Imaging for Breast Cancer Detection: Effects of Training on Performance and Agreement of Subspecialty Radiologists

  • Yeon Soo Kim;Su Hyun Lee;Soo-Yeon Kim;Eun Sil Kim;Ah Reum Park;Jung Min Chang;Vivian Youngjean Park;Jung Hyun Yoon;Bong Joo Kang;Bo La Yun;Tae Hee Kim;Eun Sook Ko;A Jung Chu;Jin You Kim;Inyoung Youn;Eun Young Chae;Woo Jung Choi;Hee Jeong Kim;Soo Hee Kang;Su Min Ha;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.11-23
    • /
    • 2024
  • Objective: To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI). Materials and Methods: A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive. The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC). Results: Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI]: 59.4-79.9), 90.8% (95% CI: 85.6-94.2), and 83.5% (95% CI: 78.6-87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI: 90.8-97.5; P = 0.001) and accuracy (85.9%; 95% CI: 80.9-89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI: 58.1-79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI: 0.52-0.63) before training and 0.68 (95% CI: 0.62-0.74) after training, with a difference of 0.11 (95% CI: 0.02-0.18; P = 0.01). The ICC was 0.73 (95% CI: 0.69-0.74) before training and 0.79 (95% CI: 0.76-0.80) after training (P = 0.002). Conclusion: Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.