엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 가솔린엔진오일 (Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Gasoline Engine Oil)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제22권5호
    • /
    • pp.260-268
    • /
    • 2006
  • The dielectric constants of used gasoline engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$ Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz,,and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 4% for gasoline engine oil.

엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 디젤엔진오일 (Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Diesel Engine Oil)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제22권5호
    • /
    • pp.290-300
    • /
    • 2006
  • The dielectric constants of used diesel engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$. Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz, and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 10% for diesel engine oil.

원통형 다전극식 정전용량-전기전도도 센서를 이용한 연료전지 차량용 냉각수의 유전특성 평가 (Evaluation about Dielectric Property of Heat Transfer Fluids for Fuel Cell Vehicle using Cylindrical Multi-Terminal Capacitive-Conductive Sensor)

  • 김재훈;김주한;김윤형;최강월;한상옥;용기중
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1087-1094
    • /
    • 2010
  • We have developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid. It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Also to assess diagnosis characteristics of heat transfer fluid, i.e. coolant, we have performed accelerated aging test using developed sensor attached to cooling system. Consequently, it was measured dielectric and electric resistance of coolant to estimate and analyse for dielectric properties by degradation condition.

친환경 변압기 절연유의 특성 (Performance of environment friendly insulating dielectric oil for power transformer)

  • 한동희;조한구;한세원;안명상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.453-456
    • /
    • 2004
  • This paper surveys the latest findings on vegetable-oil-based dielectric coolants in power systems. In recent years, environmental concerns have been increased on the use of poorly biodegradable mineral oils in distribution and power transformers in regions where spills from leaks and equipment failure could contaminate the surroundings. In addition, there are demands to improve equipment efficiencies in power systems. In this reason, researches were started in the mid 1990s to develop a fully biodegradable dielectric coolants. Vegetable oil was considered the most likely candidate for a fully biodegradable dielectric coolants. Vegetable-oil-based dielectric coolants provide the advantages of high level of biodegradability, renewable natural resource, non-toxic properties, enhanced fire safety, more effective cooling and good dielectric strength for many electrical equipment.

  • PDF

Electrical Strength of the Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck-Kweon;Kim, Chung-Hyeok;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Song, Min-Jong;Lee, Joon-Ung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.149-150
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of unfilled epoxy and filled epoxy in $LN_2$ was analyzed. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

  • PDF

세라믹 유전체 물질과 냉매 유로 형상에 따른 정전척 냉각에 관한 연구 (A Study on Electrostatic Chuck Cooling by Ceramic Dielectric Material and Coolant path)

  • 김대현;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.85-89
    • /
    • 2018
  • Temperature uniformity of a wafer in a semiconductor process is a very important factor that determines the overall yield. Therefore, it is very important to confirm the temperature characteristics of the chuck surface on which the wafer is lifted. The temperature characteristics of the chuck depend on the external heat source, the shape of the cooling channel inside the chuck, the material on the chuck surface, and so on. In this study, CFD confirms the change of temperature characteristics according to the stacking order of ceramic materials and inner coolant path on the chuck surface. Finally this study suggests the best cooling condition of electrostatic chuck.

초전도 기기의 전기절연 (Electrical Insulation for Superconducting Apparatus)

  • 곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.11-14
    • /
    • 1989
  • Some experimental studies on the dielectric strength characteristics of organic material under compressive stress associated with high magnetic fields and of liquid coolant in the presence of thermally induced bubble, which might be generated at unexpected quench of immersed-cooling superconducting devices, was performed to obtain the basic data on the electrical insulation design for superconducting apparatus. PET and liquid nitrogen were used as test mediums.

  • PDF

Treatment of EDTA Contained Reactor Coolant Using Water Dielectric Barrier Discharge Plasma

  • Song, Sang-Heon;Kwon, Daniel;Kim, Gon-Ho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2005년도 춘계학술발표회
    • /
    • pp.251-252
    • /
    • 2005
  • Streamer mode plasma is generated in the water DBD. Driving frequency is an important parameter for improving the discharge efficiency. With the optimum frequency, the decomposition of EDTA in the water is effectively preceded in the water-DBD plasma.

  • PDF

Analysis on the dielectric characteristics of a composite insulation system composed of LN2 and GN2

  • Kim, Junil;Lee, Onyou;Mo, Young Kyu;Bang, Seungmin;Kang, Jong O;Lee, Hongseok;Nam, Seokho;Kang, Hyoungku
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.33-36
    • /
    • 2015
  • A liquid nitrogen ($LN_2$) is usually used to be a coolant and insulant for a HTS coil system. HTS wires for a superconducting apparatus may be surrounded by gaseous nitrogen ($GN_2$) due to film boiling generated by a quench or voids occurred by electrical breakdown. The increased maximum electric field intensity at $GN_2$ may result in the degradation of dielectric strength of a HTS coil system. In this paper, a study on the dielectric characteristics of a composite insulation system composed of $LN_2$ and $GN_2$ is performed. A sphere-to-plane electrode system made with stainless steel is used to perform the experiments under AC and lightning impulse voltage condition. A sphere electrode is surrounded by $GN_2$ and a plane electrode is immersed into $LN_2$ to conduct dielectric experiments with a composite insulation system. The dielectric experiments are performed according to the level of $LN_2$ from the plane electrode to a sphere electrode. It is found that the dielectric characteristics of a composite insulation system are dependent on the level of $LN_2$ and the field utilization factor of an electrode system.

A Study on the Electrical Strength of Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck Kweon;Kim, Chung-Hyeok;Pak, Min-Sun;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Lee, Joon-Ung;Song, Min-Jong;Choi, Woon-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권6호
    • /
    • pp.294-300
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of some insulating materials, such as unfilled epoxy, filled epoxy, and polyimide in $LN_2$ was analyzed. Epoxy is a good insulating material but fragile at cryogenic temperature. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.