• 제목/요약/키워드: dielectric barrier corona discharge

검색결과 11건 처리시간 0.029초

3전극이 부설된 틈새 장벽방전형 플라즈마장치의 코로나 방전 및 오존발생 특성 (Corona Discharge and Ozone Generation Characteristics of a Slit Dielectric Barrier Discharge Type Plasma Reactor with a Third Electrode)

  • 문재덕;정재승
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.583-587
    • /
    • 2007
  • Corona discharge and ozone generation characteristics of a slit dielectric barrier discharge type wire-plate plasma reactor with a third electrode have been investigated. When a third electrode is installed on a slit of the slit barrier, where an intense corona discharge occurs, it is found that a significantly increased ozone output could be obtained. This, however, indicates that the third electrode can activate the corona discharges both of the discharge wire and the slit of the slit barrier in the plasma reactor. As a result, a thin stainless wire, used as the third electrode has a strong effect to influence the corona discharge of the slit and corona wire, especially to the negative corona discharge. Higher amounts of the output ozone and ozone yield, about 1.27 and 1.29 times for the negative corona discharge, can be obtained with the third electrode, which reveals the effectiveness of the third electrode.

직류 코로나 하전된 강유전체구 층의 연면방전특성 (Surface Discharge Characteristics of a DC Corona Charged Ferroelectric Pellet Barrier)

  • 금상택;이근택;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.385-390
    • /
    • 1999
  • Surface corona discharge characteristics of a dc corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charges stored on the surfaces of the ferroelectric pellets by a dc corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between corona tip and mesh electrode. Positive and negative dc voltages were applied to the tip to generate partial discharges, and corona currents were estimated to investigate the buildup charge on ferroelectric pellets as a function of the applied time and the charge relaxation time constants of ferroelectric pellets. As a result, in the case of the negative corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be fenerated efficiently. It is also found that, charge relaxation time, dielectric constants offerroelectric pellets, polarity of applied voltage and applied time affected to the surface discharges among the ferroelectric pellets.

  • PDF

슬릿 유전체 장벽을 갖는 선대 평판형 방전장치의 방전 및 오존 발생특성 (Discharge and Ozone Generation Characteristics of a Wire-Plate Discharge System with a Slit Barrier)

  • 문재덕;정재승
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.421-426
    • /
    • 2005
  • A wire-plate discharge system with a slit barrier has been proposed and investigated experimentally by focusing on the discharges on the slit barrier and ozone generation characteristics. This wire-plate discharge system with a slit barrier can generate an intensive corona discharges, and produce corona discharge twice, once from the corona wire electrode and second time from the surface and the slits of the slit dielectric barrier. As a result this propose wire-plate discharge system with the slit barrier can produce greatly increased ozone than without the slit barrier. This type of wire-plate discharge system with the slit barrier could be used for effective ozone generation as a means with retard to the removal of pollutant gas

틈새 장벽을 이용한 효과적인 오존 발생 (Effective Ozone Generation Utilizing a Slit Barrier)

  • 문재덕;정재승
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.323-327
    • /
    • 2006
  • In this paper a new wire-wire discharge system with a slit dielectric harrier has been proposed, and, its corona discharge and ozone generation characteristics have been investigated experimentally. When the slit mica barrier is installed between corona wires, instead of the grounded plate electrode, a significant increase in the generation of ozone, about 2.2 times higher than that of the conventional ones without the slit harrier, could be obtained. Photographs show that this type of discharge system with a slit barrier was found to produce a corona discharge twice, once from the upper and bottom corona wires, and. again from both sides of surfaces and slits of the slit barrier. As a result, the proposed discharge system has the potential to increase significantly ozone production and it may be useful as an effective means for removing pollutant gases.

알루미나 반응기에서의 이산화탄소의 무성방전 특성 (Silent Discharge Characteristics of $CO_2$ for Alumina Imbedded-Discharge Reacted)

  • 조문수;곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1061-1064
    • /
    • 2001
  • Deep Interests have been paid on the application of non-thermal plasma technique to solve the environmental pollution problems. $CO_2$, is one of the severe pollutants which cause the acid rain and global warming. In this study, in order to improve the conversion efficiency of $CO_2$, the streamer corona discharge plasma and barrier discharge plasma reactors were made, and the conversion characteristics of $CO_2$by the corona discharge plasma and some discharge characteristics of these discharge chambers are studied experimentally.

  • PDF

방전 플라즈마에 의한 이산화탄소 전환 효율 상승에 관한 연구 (Study of the Increase of Conversion Efficiency of $CO_2$ by Discharge Plasmas)

  • 조문수;곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.904-907
    • /
    • 2002
  • In this study, the plasma-assisted $CO_2$ conversion characteristics were investigated in the streamer corona discharge and silent discharge reactors with dielectric of $Al_2O_3$, to improve the conversion efficiency $CO_2$. Some discharge characteristics of $CO_2$ as parameters of gap spacing and applied voltage frequency, in both corona and silent discharge reactor were also obtained. The maximum $CO_2$ conversion rate was 10.1 [%] under the 5.2 [W] of discharge power and 250 [Hz] of applied voltage frequency.

  • PDF

에틸메타크릴레이트 증기 분위기에서 코로나 방전 처리한 PVDF 필름의 XPS 분석 (XPS Analysis of PVDF Film Treated by Corona Discharge in Ethyl Methacrylate Vapor Atmosphere)

  • 문희권;서문규
    • 공업화학
    • /
    • 제27권6호
    • /
    • pp.627-632
    • /
    • 2016
  • PVDF-PVC 적층필름의 계면접착력을 향상시키기 위한 새로운 방법으로 PVDF 필름 표면에 유전체장벽 코로나 방전을 통한 EMA 단량체 커플링을 시도하였다. EMA 1% 분위기에서 코로나 표면처리한 PVDF 필름을 사용하여 제조한 PVDF-PVC 적층필름의 계면접착력은 코로나 처리하지 않은 PVDF에 비해 현저히 향상되었다. 코로나 방전처리에 의해 PVDF 필름 표면의 접촉각은 현저히 감소하였다. XPS 분석 결과, 코로나 처리에 의해 필름 표면의 탄소와 산소함량은 증가하는 반면 불소 함량은 감소하였다. XPS $C_{1s}$ 피크의 curve fitting 결과, 코로나 방전 처리에 의해 비극성 C-C 결합 탄소와 산소와 결합하는 탄소의 비율은 점차 증가한 반면, 불소와 결합하는 탄소의 비율은 크게 감소하는 경향을 나타내었다.

공기/석영관(空氣/石英管) 복합유전체(複合誘電體)장벽층(障壁層)의 고주파(高周波) 펄스 방전(放電) 특성(特性) (Air/Quartz Dielectric Double Barrier Pulse Discharge)

  • 이응관;우정욱;정석환;이동훈;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1556-1558
    • /
    • 1994
  • An air/quartz dielectric double barrier pulse discharge has been investigated to develop a novel si lent type ozone generator. It is found that there are very active pulsed coronas occurred in the airgap which are very useful for ozone generation. And, the corona onset voltage of the airgap of the air/quartz double barrier was enfluenced greatly by the airgap of the air/quartz dielectric double barrier, and depended greatly upon the airgap ranged of $0.0{\sim}3.0mm$ and by the quartz tube thickness ranged of $1.75{\sim}2.25mm$.

  • PDF

슬라이딩아크 방전과 코로나 방전의 복합공정을 통한 유해물질 처리효율 개선에 관한 연구 (A Study on Combined Processes of Sliding Arc Plasma and Corona Dielectric Barrier Discharge for Improve the Efficiency Treatment of Harmful Substance)

  • 권우택;이우식
    • 한국화재소방학회논문지
    • /
    • 제28권6호
    • /
    • pp.108-113
    • /
    • 2014
  • 유해물질처리를 효율적으로 개선하기 위해 슬라이딩아크방전(sliding arc plasma)과 corona dielectric barrier discharge(CDBD공정)의 복합공정을 이용하였다. 이장치는 OH 라디칼과 음이온을 생성하여 강력한 산화력으로 탈취 및 살균 효과를 가진다. 실험결과 SAP 반응기의 크기를 80 A를 50 A로 축소하여도 유해물질의 농도는 큰 변화가 없는 것으로 나타나 반응기의 규모를 최소화할 수 있을 것으로 판단된다. 그리고 CDBD 반응기에서 생성된 음이온과 오존은 유해물질과 반응한 후 음이온은 510,000 ppb에서 470 ppb, 오존은 98 ppb에서 22 ppb로 낮아짐을 확인하였다. 또한 플라즈마 발생장치의 안정성 및 내구성이 우수한 것으로 판단되었다. 따라서 본 연구를 통하여 향후 플라즈마복합공정을 이용하여 실내공기중에 존재하는 유해물질 제거를 효율적으로 할 수 있을 것으로 생각된다.

ICCD를 이용한 NO입자의 형광신호강도 측정 (Measurement of Fluorescence Signal Strength of NO Particle Using ICCD)

  • 전용우;박원주;이광식;이홍식
    • 조명전기설비학회논문지
    • /
    • 제15권4호
    • /
    • pp.23-30
    • /
    • 2001
  • 본 연구에서는 교류유전체장벽형 코로나방전을 이용하여 선대원통형 전극구조의 방전리액터내의 NO입자의 방전 Image와 형광방출파장대역[236[nm], 247[nm], 259[nm]에서의 수평방향과 수직방향의 신호강도를 ICCD카메라를 이용하여 측정하였다. 또한 방전메카니즘을 알기 위해서 방전진전시간에 따른 방전 Image와 신호강도 측정을 행하였다. NO입자의 수평과 수직방향의 신호강도는247[nm]대역에서 가장 큰 것을 확인 할 수 있었으며, 방전진전시간에 따른 수평과 수직방향의 신호강도는 큰 변화가 없었다. 특히 측정된 데이터로부터 반응장치 내부에서 일어나는 현상의 Image와 형광방출파장의 신호강도를 비교할 수 있었다.

  • PDF