• Title/Summary/Keyword: diamond identification

Search Result 23, Processing Time 0.027 seconds

Properties of the Natural and CVD Synthetic Diamonds for Identification (천연과 CVD 합성 다이아몬드의 감별을 위한 물성 연구)

  • Kim, Yunwoo;Song, Jeongho;Noh, Yunyoung;Song, Ohsung
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.4
    • /
    • pp.350-356
    • /
    • 2014
  • Recently, Chemical Vapor Deposition (CVD) synthetic diamonds have been introduced to the jewelry gem market, as CVD technology has been making considerable advances. Unfortunately, CVD diamonds are not distinguishable from natural diamonds when using the conventional gemological characterization method. Therefore, we need to develop a new identification method that is non-destructive, fast, and inexpensive. In our study, we employed optical microscopy and spectroscopy techniques, including Fourier transform infra-red (FT-IR), UV-VIS-NIR, photoluminescence (PL), micro Raman, and cathodoluminescent (CL) spectroscopy, to determine the differences between a natural diamond (0.30 cts) and a CVD diamond (0.43 cts). The identification of a CVD diamond was difficult when using standard gemological techniques, UV-VIS-NIR, or micro-Raman spectroscopy. However, a CVD diamond could be identified using a FT-IR by the Type II peaks. In addition, we identified a CVD diamond conclusively with the uneven UV fluorescent local bands, additional satellite PL peaks, longer phosphorescence life time, and uneven streaks in the CL images. Our results suggest that using FT-IR combined with UV fluorescent images, PL, and CL analysis might be an appropriate method for identifying CVD diamonds.

Identification for the Vivid Yellow Diamonds (비비드 옐로우 다이아몬드의 감별 방안 연구)

  • Song, Jeongho;Yun, Yury;Song, Ohsung
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.493-497
    • /
    • 2012
  • We propose a new reliable, fast, and low cost identification method for similarly looking 0.3ct vivid yellow color of natural, HPHT treated, and synthesized diamonds. Conventional optical microscopy as well as low temperature PL(photoluminescence), FT-IR, UV-VIS-NIR, micro-Raman spectroscopy, and vibrating sample magnetometry(VSM) characterization were executed. We could not distinguish the natural diamonds from the treated or the synthesized stones with an optical microscopy, PL, FT-IR, and UV-VIS-NIR spectroscopy. However, we could identify the treated diamond with micro-Raman spectroscopy due to unique $1440cm^{-1}$ peak appearance. VSM revealed easily the synthesized diamond because of its ferromagnetic behavior. Our preliminary propose on employing the Micro-Raman spectroscopy and VSM might be suitable for identification of the similar looking vivid yellow colored diamonds.

Recent trends of gem-quality colorless synthetic diamonds (보석용 무색 합성 다이아몬드의 최근 동향)

  • Choi, Hyunmin;Kim, Youngchool;Seok, Jeongwon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.4
    • /
    • pp.149-153
    • /
    • 2017
  • Recently, significant amounts of gem-quality colorless HPHT synthetic melee diamond have produced for the jewelry industry. Consequently, there have been reports of cases of fraud in the world diamond business. For example, intentionally selling synthetic diamond as natural diamond or intentionally mixing a natural diamond parcel with a synthetic. As a result, the separation of natural from synthetic melee diamonds has become increasingly critical. At present, 10,000 cubic hinge presses are used for the production of synthetic diamond in China. From among these, reportedly 1,000 presses are used for gem-quality diamond production. One press can produce up to 10ct melee-size diamonds in 24 hours. Randomly occurring pinpoint or flux-metal inclusions are diagnostic identification clues. However, some synthetic diamonds require advanced laboratory method for identification. In order to ensure consumer confidence, it is essential to screen melees so as to distinguish all synthetic goods.

Preparation of Diamond Thin film for Electric Device and Crystalline Growth (전자 디바이스용 다이아몬드 박막의 제조 및 결정성장 특성)

  • Kim, Gru-Sik;Park, Soo-Gil;Son, Won-Keun;Fujishiama, Akira
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1720-1723
    • /
    • 2000
  • Boron doped conducting diamond thin film were grown on Si substrate by microwave plasma chemical vapor deposition from a gaseous feed of hydrogen, acetone/methanol and solid boron. The doping level of boron was controlled from 0ppm to $10^4$ppm (B/C). The Si substrate was tilted ca. 10$^{\circ}$ to make Si substrate have different height and temperature. Experimental results show that same condition but different temperature of Si substrate by height made different crystalline of diamond thin film. There were appeared 3$\sim$4 step of different crystalline morphology of diamond. To characterize the boron-doped diamond thin film, Raman spectroscopy was used for identification of crystallinity. To survey surface morphology, microscope was used. Grain size was changed gradually by different temperature due to different height. The Raman spectrum of film exhibited a sharp peak at 1334$cm^{-1}$, which is characteristic of crystalline diamond. The lower position of diamond film position, the more non-diamond component peak appeared near 1550$cm^{-1}$.

  • PDF

High pressure X-ray diffraction study on a graphite using Synchrotron Radiation (고압하에서 방사광을 이용한 흑연에 대한 연구)

  • Kim, Young-Ho;Na, Ki-Chang
    • The Journal of the Petrological Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.34-40
    • /
    • 1994
  • High pressure X-ray diffraction study was carried out on a graphite to investigate its compressibility as well as any possible phase transition to the hexagonal diamond structure at room temperature. Energy dispersive X-ray diffraction method was introduced using a Mao-Bell type diamond anvil cell with Synchrotron Radiation. Polycrystalline sodium chloride was compressed together with graphite for the high pressure determinations. Because of the poor resolution of the X-ray diffraction pattern of graphite, its compressibility was estimated to be almost same as that of NaCl by graphite (002) X-ray diffraction peak only. An observation of any new peak from a possible hexagonal diamond phase seems very unplausible for its definite identification based on the present data. Alternative approaches such as an Wiggler Radiation source as well as a Large Volume high pressure apparatus will be necessary for the detailed studies on a graphite in future.

  • PDF

Identification of natural colored diamonds using UV fluorescent and X-ray Lang images (UV 형광과 X-선 Lang 표면이미지를 이용한 천연유색다이아몬드의 감별 연구)

  • Kim, Jun-Hwan;Ha, Jun-Seok;Kim, Ki-Hoon;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3540-3545
    • /
    • 2009
  • Due to recent development of high temperature high pressure(HTHP) diamond synthetic and treatment technology, we need to identify the natural diamonds fast, reliable, and economically. We proposed using new method of UV fluorescence and X-ray Lang topography imaging for distinguishing one synthetic diamond from four natural colored diamonds. We observe unique local stress field uneven image in synthetic diamond using UV fluorescence and Lang topography characterization, while uniform images in natural diamonds. Especially, X-ray Lang method offered the better identification power with better high resolution on stress field images.

System identification and admittance model-based nanodynamic control of ultra-precision cutting process (다이아몬드 터닝 머시인의 극초정밀 절삭공정에서의 시스템 규명 및 제어)

  • 정상화;김상석;오용훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1352-1355
    • /
    • 1996
  • The control of diamond turning is usually achieved through a laser-interferometer feedback of slide position. If the tool post is rigid and the material removal process is relatively static, then such a non-collocated position feedback control scheme may surface. However, as the accuracy requirement gets tighter and desired surface contours become more complex, the need for a direct tool-tip sensing becomes inevitable. The physical constraints of the machining process prohibit any reasonable implementation of a tool-tip motion measurement. It is proposed that the measured force normal to the face of the workpiece can be filtered through an appropriate admittance transfer function to result in the estimated depth of cut. This can be compared to the desired depth of cut to generate the adjustment control action in addition to position feedback control. In this work, the design methodology on the admittance model-based control with a conventional controller is presented. The recursive least-squares algorithm with forgetting factor is proposed to identify the parameters and update the cutting process in real time. The normal cutting forces are measured to identify the cutting dynamics in the real diamond turning process using the precision dynamometer. Based on the parameter estimation of cutting dynamics and the admittance model-based nanodynamic control scheme, simulation results are shown.

  • PDF

Characterization of High Pressure-High Temperature Treated Gem Diamonds (고압고온 처리된 보석용 다이아몬드의 감별 연구)

  • Song, Oh-Sung
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.5
    • /
    • pp.229-234
    • /
    • 2006
  • Diamonds have been widely employed as polishing media for precise machining and noble substrates for microelectronics. The recent development of the split sphere press has led to the enhancement of low quality natural diamonds. Synthesized and treated diamonds are sometimes traded deceptively as high quality natural diamonds because it is hard to distinguish among these diamonds with conventional gemological characterization method. Therefore, we need to develop a new identification method that is non-destructive, fast, and inexpensive. We proposed using new methods of UV fluorescence and X-ray Lang topography for checking the local HPHT stress field to distinguish these diamonds from natural ones. We observe unique differences in the local stress field images in treated diamonds using UV fluorescence and Lang topography characterization. Our result implies that our proposed methods may be appropriate for identification of the treated diamonds.

A study on the identification of HPHT diamond by the photoluminescence (PL을 이용한 HPHT 처리된 다이아몬드 감별에 관한 연구)

  • 김영출;김판채
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.1
    • /
    • pp.31-35
    • /
    • 2003
  • The PL data bases reveal the fact that a part of lattice of HPHT treated diamond is reconfigured by the reduction, elimination, generation, and movement of vacancies and interstitials as well as of impurity elements. In particular, this very sensitive method clearly illustrated that minute amount of nitrogen impurities is present in all of these type IIa diamonds, and reveal the presence of a considerable number of point defects dispersed throughout the crystal lattice.

Current insights into inherited bone marrow failure syndromes

  • Chung, Nack-Gyun;Kim, Myungshin
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.8
    • /
    • pp.337-344
    • /
    • 2014
  • Inherited bone marrow failure syndrome (IBMFS) encompasses a heterogeneous and complex group of genetic disorders characterized by physical malformations, insufficient blood cell production, and increased risk of malignancies. They often have substantial phenotype overlap, and therefore, genotyping is often a critical means of establishing a diagnosis. Current advances in the field of IBMFSs have identified multiple genes associated with IBMFSs and their pathways: genes involved in ribosome biogenesis, such as those associated with Diamond-Blackfan anemia and Shwachman-Diamond syndrome; genes involved in telomere maintenance, such as dyskeratosis congenita genes; genes encoding neutrophil elastase or neutrophil adhesion and mobility associated with severe congenital neutropenia; and genes involved in DNA recombination repair, such as those associated with Fanconi anemia. Early and adequate genetic diagnosis is required for proper management and follow-up in clinical practice. Recent advances using new molecular technologies, including next generation sequencing (NGS), have helped identify new candidate genes associated with the development of bone marrow failure. Targeted NGS using panels of large numbers of genes is rapidly gaining potential for use as a cost-effective diagnostic tool for the identification of mutations in newly diagnosed patients. In this review, we have described recent insights into IBMFS and how they are advancing our understanding of the disease's pathophysiology; we have also discussed the possible implications they will have in clinical practice for Korean patients.