Evaluation and Experimental Production of Single-Phase Full-wave Rectification Type for X-ray Equipment of High Precision (고정밀도의 단상전파정류형 X선 장치의 제작 및 평가)

  • Han, Dong-Kyoon;Jung, Jae-Eun;Choi, Jun-Gu;Seoun, Youl-Hun;Ko, Shin-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.413-419
    • /
    • 2011
  • Diagnosis X-ray equipment localized at 1950's but it is developed suddenly at 1960's with demand together. Manufacture of Diagnostic X-ray equipment is controled by the KS regulation and the Ministry of Health and Welfare because of hazardous element etc. exposure by radiation. Most of diagnostic X-ray equipment ware single phase and three phase full-wave rectification but from 1980's it transforms it was exchanged in inverter type X-ray equipment. Inverter type X-ray equipment produces approximately 50~80% more average photon intensity then single phase full-wave rectification and the accuracy is high. But from a clinic it dose not use because expensive therefor the efficiency improvement of single phase full-wave rectification is necessary. We produced single phase full-wave rectification X-ray equipment control unit, high tension transformer, filament heating transformer, rectification circuit, high tension cable and others and evaluated efficiency, in result which is excellent compare with Rule of Safety Management and KS regulation.

A Study on Activities of Diagnostic X-ray Examination(II) (X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II))

  • Kyong, Kwang-Hyon;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

The Recent Trend of the National and International Standard of Manufacturing Quality Control for Diagnostic X-ray Equipment (진단용엑스선장치 제조품질관리에 관한 국내.외 규격의 동향)

  • Choi, In-Seok;Kim, Jung-Min;Jeong, Hoi-Woun;Min, Jung-Whan;Lee, In-Su
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.1-15
    • /
    • 2009
  • Newly published IEC 60601-1-3 ; 2008 2nd Edition has two important meanings. First, Radiation Quality and Dose should make sure for safety of patient and staff in manufacturing diagnostic X-ray equipment. Second, it should be minimized of Leakage Radiation, Residual Radiation, and Stray Radiation. The requirement to make enactment or revision of national standard for diagnostic X-ray Equipment is as follows : 1. It should be adjusted the new standard to the recent IEC Publication under the consideration of the Korea medical circumstances. 2. For focus to the Radiation Safety, IEC 60601-1-3 (General requirements for radiation protection in diagnostic X-ray equipment) could be applied to the new regulation. It should be compact sentence. 3. A sudden Notification change should not be desired. It needs a enough time to make easy the circumstances.

  • PDF

Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment (진단용엑스선촬영장치의 간접 선량 계산법 개발)

  • Kim, Jung-Su;Kim, Sung-Hwan;Jeon, Min-Cheol;Ju, Won-Ha;Jeong, Min-Gyu;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.

Fundamental Study of nanoDot OSL Dosimeters for Entrance Skin Dose Measurement in Diagnostic X-ray Examinations

  • Okazaki, Tohru;Hayashi, Hiroaki;Takegami, Kazuki;Okino, Hiroki;Kimoto, Natsumi;Maehata, Itsumi;Kobayashi, Ikuo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.229-236
    • /
    • 2016
  • Background: In order to manage the patient exposure dose in X-ray diagnosis, it is preferred to evaluate the entrance skin dose; although there are some evaluations about entrance skin dose, a small number of report has been published for direct measurement of patient. We think that a small-type optically stimulated luminescence (OSL) dosimeter, named nanoDot, can achieve a direct measurement. For evaluations, the corrections of angular and energy dependences play an important role. In this study, we aimed to evaluate the angular and the energy dependences of nanoDot. Materials and Methods: We used commercially available X-ray diagnostic equipment. For angular dependence measurement, a relative response of every 15 degrees of nanoDot was measured in 40-140 kV X-ray. And for energy dependence measurement, mono-energetic characteristic X-rays were generated using several materials by irradiating the diagnostic X-rays, and the nanoDot was irradiated by the characteristic X-rays. We evaluated the measured response in an energy range of 8.1-75.5 keV. In addition, we performed Monte-Carlo simulation to compare experimental results. Results and Discussion: The experimental results were in good agreement with those of Monte-Carlo simulation. The angular dependence of nanoDot was almost steady with the response of 0 degrees except for 90 and 270 degrees. Furthermore, we found that difference of the response of nanoDot, where the nanoDot was irradiated from the randomly set directions, was estimated to be at most 5%. On the other hand, the response of nanoDot varies with the energy of incident X-rays; slightly increased to 20 keV and gradually decreased to 80 keV. These results are valuable to perform the precise evaluation of entrance skin dose with nanoDot in X-ray diagnosis. Conclusion: The influence of angular dependence and energy dependence in X-ray diagnosis is not so large, and the nanoDot OSL dosimeter is considered to be suitable dosimeter for direct measurement of entrance surface dose of patient.

Evaluation of the Reproducibility of Radiation Output from Diagnostic X-ray Equipment(Standards Based on IEC 60601-2-54) (진단용 X선 장치에서 방사선출력의 재현성 평가(IEC 60601-2-54 표준규격을 기반으로))

  • Han, Beom-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Chong-Yeal;Lee, Sang-Ho;Han, Sang-Hyun;Hong, Dong-Hee;Kim, Chang-Gyu;You, In-Gyu;Mo, Eun-Hee
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.555-561
    • /
    • 2014
  • For five diagnostic X-ray generators (DR), four units turned out to be appropriate in tests on the reproducibility of radiation output suggested in the IEC 60601-2-54 standard, but in one unit of the X-ray equipment, an item measured in a combination of 50% of the highest tube voltage of the diagnostic X-ray equipment, the test setting of Group C with authorized output doses between $1{\mu}Gy$ and $5{\mu}Gy$ of mAs turned out to be inappropriate. As a result, the radiation dose to the IEC 60601-2-54 standard for quantification standards proposed by the radiation output from diagnostic X-ray imaging device reproducibility of performance management should be aware that an important evaluation factor.

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

A Study on the Architectural Planning of the X-ray Unit in General Hospital (종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구)

  • Youn, Woo-Young;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • Na, Gil-Ju;Baek, Su-Ung;Yang, Hyeon-Hun;Park, Gye-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

Improved X-ray Center Beam Alignment Evaluation Method (개선된 X선 중심선속정렬평가 측정법)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.827-832
    • /
    • 2020
  • X-ray equipment, which is frequently used in radiology and treatment, is the most common and most used equipment in clinical practice. Equipment must provide accurate information to patients through continuous quality control. In case of manual quality control measurement, reproducibility may be poor and there may be a problem with reliability of evaluation results. In this study, an automated program was developed and attempted to measure how much the central ray between the focus of the X-ray tube and the variable aperture of the diagnostic X-ray generator used in clinical practice coincides. As a result of the experiment, it succeeded in calculating the coordinates of the two center points, and the distance between the two points was calculated in pixels and applied to the judgment and the automatic judgment value for whether the center line coincidence is within the normal angle or the abnormal angle is presented. The results of this study are considered to be very helpful in the quality control of the X-ray apparatus.